Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
PURPOSE: This study aimed to compare the success and complication rates among patients implanted with Ahmed Glaucoma Valve (AGV) using the short and long tunnel technique through retrospective chart review. PATIENTS AND METHODS: We reviewed 54 charts of adult patients who underwent AGV implantation...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290859/ https://www.ncbi.nlm.nih.gov/pubmed/37366517 http://dx.doi.org/10.2147/OPTH.S405924 |
_version_ | 1785062579928825856 |
---|---|
author | San Pedro, Marie Jeremy B Gomez, James Paul S Leuenberger, Edgar U |
author_facet | San Pedro, Marie Jeremy B Gomez, James Paul S Leuenberger, Edgar U |
author_sort | San Pedro, Marie Jeremy B |
collection | PubMed |
description | PURPOSE: This study aimed to compare the success and complication rates among patients implanted with Ahmed Glaucoma Valve (AGV) using the short and long tunnel technique through retrospective chart review. PATIENTS AND METHODS: We reviewed 54 charts of adult patients who underwent AGV implantation using a Short-Needle Track (SNT) or Long-Needle Track (LNT) technique. Intraocular pressures (IOP), Best Corrected Visual Acuity (BCVA) and number of medications were recorded pre-operatively, and at Day 1, 3, 7, Month 1, 3, 6 post-operatively. Treatment success, occurrence of Hypertensive Phase (HP), complication and procedures done after AGV implantation were compared between the two groups using one-tailed Z-test of proportions. RESULTS: A total of 20 (LNT) and 21 (SNT) charts were included in the study. There was no significant difference between the median postoperative IOP, BCVA, and number of anti-glaucoma medications between the two groups at each time interval. The comparison between the occurrence of HP (P = 0.435) and success rates (P = 0.476) between the two groups yielded no significant difference. Flat/shallow anterior chamber (AC) was seen exclusively in three eyes (14%) in the SNT group (P = 0.039). There was one occurrence of plate exposure in the LNT group (P = 0.149). CONCLUSION: The LNT technique of AGV Implantation may be used as an alternative to the traditional SNT (with autologous graft). The long needle track offers the advantage reducing the risk of complications arising from shallow anterior chamber post-operatively. |
format | Online Article Text |
id | pubmed-10290859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-102908592023-06-26 Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study San Pedro, Marie Jeremy B Gomez, James Paul S Leuenberger, Edgar U Clin Ophthalmol Original Research PURPOSE: This study aimed to compare the success and complication rates among patients implanted with Ahmed Glaucoma Valve (AGV) using the short and long tunnel technique through retrospective chart review. PATIENTS AND METHODS: We reviewed 54 charts of adult patients who underwent AGV implantation using a Short-Needle Track (SNT) or Long-Needle Track (LNT) technique. Intraocular pressures (IOP), Best Corrected Visual Acuity (BCVA) and number of medications were recorded pre-operatively, and at Day 1, 3, 7, Month 1, 3, 6 post-operatively. Treatment success, occurrence of Hypertensive Phase (HP), complication and procedures done after AGV implantation were compared between the two groups using one-tailed Z-test of proportions. RESULTS: A total of 20 (LNT) and 21 (SNT) charts were included in the study. There was no significant difference between the median postoperative IOP, BCVA, and number of anti-glaucoma medications between the two groups at each time interval. The comparison between the occurrence of HP (P = 0.435) and success rates (P = 0.476) between the two groups yielded no significant difference. Flat/shallow anterior chamber (AC) was seen exclusively in three eyes (14%) in the SNT group (P = 0.039). There was one occurrence of plate exposure in the LNT group (P = 0.149). CONCLUSION: The LNT technique of AGV Implantation may be used as an alternative to the traditional SNT (with autologous graft). The long needle track offers the advantage reducing the risk of complications arising from shallow anterior chamber post-operatively. Dove 2023-06-21 /pmc/articles/PMC10290859/ /pubmed/37366517 http://dx.doi.org/10.2147/OPTH.S405924 Text en © 2023 San Pedro et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research San Pedro, Marie Jeremy B Gomez, James Paul S Leuenberger, Edgar U Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study |
title | Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study |
title_full | Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study |
title_fullStr | Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study |
title_full_unstemmed | Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study |
title_short | Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study |
title_sort | comparison of short and long-tunnel needle track for ahmed glaucoma valve implantation in a private eye center in the philippines: a retrospective study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290859/ https://www.ncbi.nlm.nih.gov/pubmed/37366517 http://dx.doi.org/10.2147/OPTH.S405924 |
work_keys_str_mv | AT sanpedromariejeremyb comparisonofshortandlongtunnelneedletrackforahmedglaucomavalveimplantationinaprivateeyecenterinthephilippinesaretrospectivestudy AT gomezjamespauls comparisonofshortandlongtunnelneedletrackforahmedglaucomavalveimplantationinaprivateeyecenterinthephilippinesaretrospectivestudy AT leuenbergeredgaru comparisonofshortandlongtunnelneedletrackforahmedglaucomavalveimplantationinaprivateeyecenterinthephilippinesaretrospectivestudy |