Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study

PURPOSE: This study aimed to compare the success and complication rates among patients implanted with Ahmed Glaucoma Valve (AGV) using the short and long tunnel technique through retrospective chart review. PATIENTS AND METHODS: We reviewed 54 charts of adult patients who underwent AGV implantation...

Descripción completa

Detalles Bibliográficos
Autores principales: San Pedro, Marie Jeremy B, Gomez, James Paul S, Leuenberger, Edgar U
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290859/
https://www.ncbi.nlm.nih.gov/pubmed/37366517
http://dx.doi.org/10.2147/OPTH.S405924
_version_ 1785062579928825856
author San Pedro, Marie Jeremy B
Gomez, James Paul S
Leuenberger, Edgar U
author_facet San Pedro, Marie Jeremy B
Gomez, James Paul S
Leuenberger, Edgar U
author_sort San Pedro, Marie Jeremy B
collection PubMed
description PURPOSE: This study aimed to compare the success and complication rates among patients implanted with Ahmed Glaucoma Valve (AGV) using the short and long tunnel technique through retrospective chart review. PATIENTS AND METHODS: We reviewed 54 charts of adult patients who underwent AGV implantation using a Short-Needle Track (SNT) or Long-Needle Track (LNT) technique. Intraocular pressures (IOP), Best Corrected Visual Acuity (BCVA) and number of medications were recorded pre-operatively, and at Day 1, 3, 7, Month 1, 3, 6 post-operatively. Treatment success, occurrence of Hypertensive Phase (HP), complication and procedures done after AGV implantation were compared between the two groups using one-tailed Z-test of proportions. RESULTS: A total of 20 (LNT) and 21 (SNT) charts were included in the study. There was no significant difference between the median postoperative IOP, BCVA, and number of anti-glaucoma medications between the two groups at each time interval. The comparison between the occurrence of HP (P = 0.435) and success rates (P = 0.476) between the two groups yielded no significant difference. Flat/shallow anterior chamber (AC) was seen exclusively in three eyes (14%) in the SNT group (P = 0.039). There was one occurrence of plate exposure in the LNT group (P = 0.149). CONCLUSION: The LNT technique of AGV Implantation may be used as an alternative to the traditional SNT (with autologous graft). The long needle track offers the advantage reducing the risk of complications arising from shallow anterior chamber post-operatively.
format Online
Article
Text
id pubmed-10290859
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-102908592023-06-26 Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study San Pedro, Marie Jeremy B Gomez, James Paul S Leuenberger, Edgar U Clin Ophthalmol Original Research PURPOSE: This study aimed to compare the success and complication rates among patients implanted with Ahmed Glaucoma Valve (AGV) using the short and long tunnel technique through retrospective chart review. PATIENTS AND METHODS: We reviewed 54 charts of adult patients who underwent AGV implantation using a Short-Needle Track (SNT) or Long-Needle Track (LNT) technique. Intraocular pressures (IOP), Best Corrected Visual Acuity (BCVA) and number of medications were recorded pre-operatively, and at Day 1, 3, 7, Month 1, 3, 6 post-operatively. Treatment success, occurrence of Hypertensive Phase (HP), complication and procedures done after AGV implantation were compared between the two groups using one-tailed Z-test of proportions. RESULTS: A total of 20 (LNT) and 21 (SNT) charts were included in the study. There was no significant difference between the median postoperative IOP, BCVA, and number of anti-glaucoma medications between the two groups at each time interval. The comparison between the occurrence of HP (P = 0.435) and success rates (P = 0.476) between the two groups yielded no significant difference. Flat/shallow anterior chamber (AC) was seen exclusively in three eyes (14%) in the SNT group (P = 0.039). There was one occurrence of plate exposure in the LNT group (P = 0.149). CONCLUSION: The LNT technique of AGV Implantation may be used as an alternative to the traditional SNT (with autologous graft). The long needle track offers the advantage reducing the risk of complications arising from shallow anterior chamber post-operatively. Dove 2023-06-21 /pmc/articles/PMC10290859/ /pubmed/37366517 http://dx.doi.org/10.2147/OPTH.S405924 Text en © 2023 San Pedro et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
San Pedro, Marie Jeremy B
Gomez, James Paul S
Leuenberger, Edgar U
Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
title Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
title_full Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
title_fullStr Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
title_full_unstemmed Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
title_short Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
title_sort comparison of short and long-tunnel needle track for ahmed glaucoma valve implantation in a private eye center in the philippines: a retrospective study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10290859/
https://www.ncbi.nlm.nih.gov/pubmed/37366517
http://dx.doi.org/10.2147/OPTH.S405924
work_keys_str_mv AT sanpedromariejeremyb comparisonofshortandlongtunnelneedletrackforahmedglaucomavalveimplantationinaprivateeyecenterinthephilippinesaretrospectivestudy
AT gomezjamespauls comparisonofshortandlongtunnelneedletrackforahmedglaucomavalveimplantationinaprivateeyecenterinthephilippinesaretrospectivestudy
AT leuenbergeredgaru comparisonofshortandlongtunnelneedletrackforahmedglaucomavalveimplantationinaprivateeyecenterinthephilippinesaretrospectivestudy