Quality control in respiratory oscillometry: reproducibility measures ignoring reactance?

This study demonstrates the inadequacy of the current technical standards of oscillometry that are based on the within-trial reproducibility of the lowest-frequency R(rs), and suggests the use of a simple variability measure encompassing both R(rs) and X(rs) https://bit.ly/3AYRid6

Detalles Bibliográficos
Autores principales: Hantos, Zoltán, Wu, Joyce K.Y., Dandurand, Ronald J., Chow, Chung-Wai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Respiratory Society 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10291313/
https://www.ncbi.nlm.nih.gov/pubmed/37377657
http://dx.doi.org/10.1183/23120541.00070-2023
_version_ 1785062667937906688
author Hantos, Zoltán
Wu, Joyce K.Y.
Dandurand, Ronald J.
Chow, Chung-Wai
author_facet Hantos, Zoltán
Wu, Joyce K.Y.
Dandurand, Ronald J.
Chow, Chung-Wai
author_sort Hantos, Zoltán
collection PubMed
description This study demonstrates the inadequacy of the current technical standards of oscillometry that are based on the within-trial reproducibility of the lowest-frequency R(rs), and suggests the use of a simple variability measure encompassing both R(rs) and X(rs) https://bit.ly/3AYRid6
format Online
Article
Text
id pubmed-10291313
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher European Respiratory Society
record_format MEDLINE/PubMed
spelling pubmed-102913132023-06-27 Quality control in respiratory oscillometry: reproducibility measures ignoring reactance? Hantos, Zoltán Wu, Joyce K.Y. Dandurand, Ronald J. Chow, Chung-Wai ERJ Open Res Research Letters This study demonstrates the inadequacy of the current technical standards of oscillometry that are based on the within-trial reproducibility of the lowest-frequency R(rs), and suggests the use of a simple variability measure encompassing both R(rs) and X(rs) https://bit.ly/3AYRid6 European Respiratory Society 2023-06-26 /pmc/articles/PMC10291313/ /pubmed/37377657 http://dx.doi.org/10.1183/23120541.00070-2023 Text en Copyright ©The authors 2023 https://creativecommons.org/licenses/by-nc/4.0/This version is distributed under the terms of the Creative Commons Attribution Non-Commercial Licence 4.0. For commercial reproduction rights and permissions contact permissions@ersnet.org (mailto:permissions@ersnet.org)
spellingShingle Research Letters
Hantos, Zoltán
Wu, Joyce K.Y.
Dandurand, Ronald J.
Chow, Chung-Wai
Quality control in respiratory oscillometry: reproducibility measures ignoring reactance?
title Quality control in respiratory oscillometry: reproducibility measures ignoring reactance?
title_full Quality control in respiratory oscillometry: reproducibility measures ignoring reactance?
title_fullStr Quality control in respiratory oscillometry: reproducibility measures ignoring reactance?
title_full_unstemmed Quality control in respiratory oscillometry: reproducibility measures ignoring reactance?
title_short Quality control in respiratory oscillometry: reproducibility measures ignoring reactance?
title_sort quality control in respiratory oscillometry: reproducibility measures ignoring reactance?
topic Research Letters
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10291313/
https://www.ncbi.nlm.nih.gov/pubmed/37377657
http://dx.doi.org/10.1183/23120541.00070-2023
work_keys_str_mv AT hantoszoltan qualitycontrolinrespiratoryoscillometryreproducibilitymeasuresignoringreactance
AT wujoyceky qualitycontrolinrespiratoryoscillometryreproducibilitymeasuresignoringreactance
AT dandurandronaldj qualitycontrolinrespiratoryoscillometryreproducibilitymeasuresignoringreactance
AT chowchungwai qualitycontrolinrespiratoryoscillometryreproducibilitymeasuresignoringreactance