“Can You Feel It”: An Early Experience with Simulated Vibration to Recreate Glenoid Reaming
When developing educational simulators, meaningful haptic feedback is important. To our knowledge, no shoulder arthroplasty surgical simulator exists. This study focuses on simulating vibration haptics of glenoid reaming for shoulder arthroplasty using a novel glenoid reaming simulator. METHODS: We...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Journal of Bone and Joint Surgery, Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10292736/ https://www.ncbi.nlm.nih.gov/pubmed/37377860 http://dx.doi.org/10.2106/JBJS.OA.22.00134 |
_version_ | 1785062878397595648 |
---|---|
author | Strelzow, Jason A. Kusins, Jonathan R. Ferreira, Louis M. LeBel, Marie-Eve |
author_facet | Strelzow, Jason A. Kusins, Jonathan R. Ferreira, Louis M. LeBel, Marie-Eve |
author_sort | Strelzow, Jason A. |
collection | PubMed |
description | When developing educational simulators, meaningful haptic feedback is important. To our knowledge, no shoulder arthroplasty surgical simulator exists. This study focuses on simulating vibration haptics of glenoid reaming for shoulder arthroplasty using a novel glenoid reaming simulator. METHODS: We validated a novel custom simulator constructed using a vibration transducer transmitting simulated reaming vibrations to a powered nonwearing reamer tip through a 3D-printed glenoid. Validation and system fidelity were evaluated by 9 fellowship-trained shoulder surgeon experts performing a series of simulated reamings. We then completed the validation process through a questionnaire focused on experts' experience with the simulator. RESULTS: Experts correctly identified 52% ± 8% of surface profiles and 69% ± 21% of cartilage layers. Experts identified the vibration interface between simulated cartilage and subchondral bone (77% ± 23% of the time), indicating high fidelity for the system. An interclass correlation coefficient for experts' reaming to the subchondral plate was 0.682 (confidence interval 0.262-0.908). On a general questionnaire, the perceived utility of the simulator as a teaching tool was highly ranked (4/5), and experts scored “ease of instrument manipulation” (4.19/5) and “realism of the simulator” (4.11/5) the highest. The mean global evaluation score was 6.8/10 (range 5-10). CONCLUSIONS: We examined a simulated glenoid reamer and feasibility of haptic vibrational feedback for training. Experts validated simulated vibration feedback for glenoid simulation reaming, and the results suggested that this may be a useful additional training adjuvant. LEVEL OF EVIDENCE: Level II, prospective study. |
format | Online Article Text |
id | pubmed-10292736 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Journal of Bone and Joint Surgery, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-102927362023-06-27 “Can You Feel It”: An Early Experience with Simulated Vibration to Recreate Glenoid Reaming Strelzow, Jason A. Kusins, Jonathan R. Ferreira, Louis M. LeBel, Marie-Eve JB JS Open Access AOA Critical Issues in Education When developing educational simulators, meaningful haptic feedback is important. To our knowledge, no shoulder arthroplasty surgical simulator exists. This study focuses on simulating vibration haptics of glenoid reaming for shoulder arthroplasty using a novel glenoid reaming simulator. METHODS: We validated a novel custom simulator constructed using a vibration transducer transmitting simulated reaming vibrations to a powered nonwearing reamer tip through a 3D-printed glenoid. Validation and system fidelity were evaluated by 9 fellowship-trained shoulder surgeon experts performing a series of simulated reamings. We then completed the validation process through a questionnaire focused on experts' experience with the simulator. RESULTS: Experts correctly identified 52% ± 8% of surface profiles and 69% ± 21% of cartilage layers. Experts identified the vibration interface between simulated cartilage and subchondral bone (77% ± 23% of the time), indicating high fidelity for the system. An interclass correlation coefficient for experts' reaming to the subchondral plate was 0.682 (confidence interval 0.262-0.908). On a general questionnaire, the perceived utility of the simulator as a teaching tool was highly ranked (4/5), and experts scored “ease of instrument manipulation” (4.19/5) and “realism of the simulator” (4.11/5) the highest. The mean global evaluation score was 6.8/10 (range 5-10). CONCLUSIONS: We examined a simulated glenoid reamer and feasibility of haptic vibrational feedback for training. Experts validated simulated vibration feedback for glenoid simulation reaming, and the results suggested that this may be a useful additional training adjuvant. LEVEL OF EVIDENCE: Level II, prospective study. Journal of Bone and Joint Surgery, Inc. 2023-06-26 /pmc/articles/PMC10292736/ /pubmed/37377860 http://dx.doi.org/10.2106/JBJS.OA.22.00134 Text en Copyright © 2023 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | AOA Critical Issues in Education Strelzow, Jason A. Kusins, Jonathan R. Ferreira, Louis M. LeBel, Marie-Eve “Can You Feel It”: An Early Experience with Simulated Vibration to Recreate Glenoid Reaming |
title | “Can You Feel It”: An Early Experience with Simulated Vibration to Recreate Glenoid Reaming |
title_full | “Can You Feel It”: An Early Experience with Simulated Vibration to Recreate Glenoid Reaming |
title_fullStr | “Can You Feel It”: An Early Experience with Simulated Vibration to Recreate Glenoid Reaming |
title_full_unstemmed | “Can You Feel It”: An Early Experience with Simulated Vibration to Recreate Glenoid Reaming |
title_short | “Can You Feel It”: An Early Experience with Simulated Vibration to Recreate Glenoid Reaming |
title_sort | “can you feel it”: an early experience with simulated vibration to recreate glenoid reaming |
topic | AOA Critical Issues in Education |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10292736/ https://www.ncbi.nlm.nih.gov/pubmed/37377860 http://dx.doi.org/10.2106/JBJS.OA.22.00134 |
work_keys_str_mv | AT strelzowjasona canyoufeelitanearlyexperiencewithsimulatedvibrationtorecreateglenoidreaming AT kusinsjonathanr canyoufeelitanearlyexperiencewithsimulatedvibrationtorecreateglenoidreaming AT ferreiralouism canyoufeelitanearlyexperiencewithsimulatedvibrationtorecreateglenoidreaming AT lebelmarieeve canyoufeelitanearlyexperiencewithsimulatedvibrationtorecreateglenoidreaming |