Cargando…

High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing?

[Image: see text] Single-molecule sensors collect statistics of single-molecule interactions, and the resulting data can be used to determine concentrations of analyte molecules. The assays are generally end-point assays and are not designed for continuous biosensing. For continuous biosensing, a si...

Descripción completa

Detalles Bibliográficos
Autores principales: Bergkamp, Max H., Cajigas, Sebastian, van IJzendoorn, Leo J., Prins, Menno W.J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10294250/
https://www.ncbi.nlm.nih.gov/pubmed/37216442
http://dx.doi.org/10.1021/acssensors.3c00245
_version_ 1785063155612778496
author Bergkamp, Max H.
Cajigas, Sebastian
van IJzendoorn, Leo J.
Prins, Menno W.J.
author_facet Bergkamp, Max H.
Cajigas, Sebastian
van IJzendoorn, Leo J.
Prins, Menno W.J.
author_sort Bergkamp, Max H.
collection PubMed
description [Image: see text] Single-molecule sensors collect statistics of single-molecule interactions, and the resulting data can be used to determine concentrations of analyte molecules. The assays are generally end-point assays and are not designed for continuous biosensing. For continuous biosensing, a single-molecule sensor needs to be reversible, and the signals should be analyzed in real time in order to continuously report output signals, with a well-controlled time delay and measurement precision. Here, we describe a signal processing architecture for real-time continuous biosensing based on high-throughput single-molecule sensors. The key aspect of the architecture is the parallel computation of multiple measurement blocks that enables continuous measurements over an endless time span. Continuous biosensing is demonstrated for a single-molecule sensor with 10,000 individual particles that are tracked as a function of time. The continuous analysis includes particle identification, particle tracking, drift correction, and detection of the discrete timepoints where individual particles switch between bound and unbound states, yielding state transition statistics that relate to the analyte concentration in solution. The continuous real-time sensing and computation were studied for a reversible cortisol competitive immunosensor, showing how the precision and time delay of cortisol monitoring are controlled by the number of analyzed particles and the size of the measurement blocks. Finally, we discuss how the presented signal processing architecture can be applied to various single-molecule measurement methods, allowing these to be developed into continuous biosensors.
format Online
Article
Text
id pubmed-10294250
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-102942502023-06-28 High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing? Bergkamp, Max H. Cajigas, Sebastian van IJzendoorn, Leo J. Prins, Menno W.J. ACS Sens [Image: see text] Single-molecule sensors collect statistics of single-molecule interactions, and the resulting data can be used to determine concentrations of analyte molecules. The assays are generally end-point assays and are not designed for continuous biosensing. For continuous biosensing, a single-molecule sensor needs to be reversible, and the signals should be analyzed in real time in order to continuously report output signals, with a well-controlled time delay and measurement precision. Here, we describe a signal processing architecture for real-time continuous biosensing based on high-throughput single-molecule sensors. The key aspect of the architecture is the parallel computation of multiple measurement blocks that enables continuous measurements over an endless time span. Continuous biosensing is demonstrated for a single-molecule sensor with 10,000 individual particles that are tracked as a function of time. The continuous analysis includes particle identification, particle tracking, drift correction, and detection of the discrete timepoints where individual particles switch between bound and unbound states, yielding state transition statistics that relate to the analyte concentration in solution. The continuous real-time sensing and computation were studied for a reversible cortisol competitive immunosensor, showing how the precision and time delay of cortisol monitoring are controlled by the number of analyzed particles and the size of the measurement blocks. Finally, we discuss how the presented signal processing architecture can be applied to various single-molecule measurement methods, allowing these to be developed into continuous biosensors. American Chemical Society 2023-05-22 /pmc/articles/PMC10294250/ /pubmed/37216442 http://dx.doi.org/10.1021/acssensors.3c00245 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Bergkamp, Max H.
Cajigas, Sebastian
van IJzendoorn, Leo J.
Prins, Menno W.J.
High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing?
title High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing?
title_full High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing?
title_fullStr High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing?
title_full_unstemmed High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing?
title_short High-Throughput Single-Molecule Sensors: How Can the Signals Be Analyzed in Real Time for Achieving Real-Time Continuous Biosensing?
title_sort high-throughput single-molecule sensors: how can the signals be analyzed in real time for achieving real-time continuous biosensing?
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10294250/
https://www.ncbi.nlm.nih.gov/pubmed/37216442
http://dx.doi.org/10.1021/acssensors.3c00245
work_keys_str_mv AT bergkampmaxh highthroughputsinglemoleculesensorshowcanthesignalsbeanalyzedinrealtimeforachievingrealtimecontinuousbiosensing
AT cajigassebastian highthroughputsinglemoleculesensorshowcanthesignalsbeanalyzedinrealtimeforachievingrealtimecontinuousbiosensing
AT vanijzendoornleoj highthroughputsinglemoleculesensorshowcanthesignalsbeanalyzedinrealtimeforachievingrealtimecontinuousbiosensing
AT prinsmennowj highthroughputsinglemoleculesensorshowcanthesignalsbeanalyzedinrealtimeforachievingrealtimecontinuousbiosensing