Cargando…
Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study
BACKGROUND: Many studies demonstrated that surgical guides might reduce discrepancies compared with freehand implant placement. This randomized crossover study aimed to assess the effects of approaches, practitioners’ experience and learning sequences on the accuracy of single tooth implantation via...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10294323/ https://www.ncbi.nlm.nih.gov/pubmed/37370027 http://dx.doi.org/10.1186/s12903-023-03116-6 |
_version_ | 1785063169883897856 |
---|---|
author | Li, Sha Yi, Chun Yu, Ziyang Wu, Aozhou Zhang, Yu Lin, Ye |
author_facet | Li, Sha Yi, Chun Yu, Ziyang Wu, Aozhou Zhang, Yu Lin, Ye |
author_sort | Li, Sha |
collection | PubMed |
description | BACKGROUND: Many studies demonstrated that surgical guides might reduce discrepancies compared with freehand implant placement. This randomized crossover study aimed to assess the effects of approaches, practitioners’ experience and learning sequences on the accuracy of single tooth implantation via digital registration method. No similar study was found. METHODS: This in vitro randomized crossover study enrolled 60 novice students (Group S) and 10 experienced instructors (Group I). Sixty students were randomly and evenly assigned to two groups (Group SA and SB). In Group SA, 30 students first performed single molar implant on a simulation model freehand (Group SAFH), and then with a CAD/CAM surgical guide (Group SASG). In Group SB, another 30 students first performed guided (Group SBSG) and then freehand (Group SBFH). Ten instructors were also divided into Group IAFH/IASG (n = 5) and IBSG/IBFH (n = 5) following the same rules. The accuracy of implant placement was assessed by the coronal and apical distance (mm) and angular (°) deviations using the digital registration method. T tests and nonparametric tests were used to compare the results among different groups of approaches, experience and sequences. RESULTS: For students, the coronal and apical distance and the angular deviations were significantly lower in surgical guide group than freehand group in total and in learning freehand first subgroup, but for learning surgical guide first subgroup the apical distance deviation showed no significant difference between two approaches. For students, the angular deviation of freehand group was significantly lower in learning surgical guide first group than learning freehand first group. For instructors, the coronal and apical distance and angular deviations showed no significant difference between two approaches and two sequences. For freehand approach, the coronal and apical distance and the angular deviations were significantly higher in student group than instructor group, while not significantly different between two groups for surgical guide approach. CONCLUSIONS: For novices, using a surgical guide for the first implant placement may reduce the potential deviations compared with freehand surgery, and may reach a comparable accuracy with that of specialists. For simple single molar implantation, the surgical guide may not be significantly helpful for experienced specialists. |
format | Online Article Text |
id | pubmed-10294323 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102943232023-06-28 Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study Li, Sha Yi, Chun Yu, Ziyang Wu, Aozhou Zhang, Yu Lin, Ye BMC Oral Health Research BACKGROUND: Many studies demonstrated that surgical guides might reduce discrepancies compared with freehand implant placement. This randomized crossover study aimed to assess the effects of approaches, practitioners’ experience and learning sequences on the accuracy of single tooth implantation via digital registration method. No similar study was found. METHODS: This in vitro randomized crossover study enrolled 60 novice students (Group S) and 10 experienced instructors (Group I). Sixty students were randomly and evenly assigned to two groups (Group SA and SB). In Group SA, 30 students first performed single molar implant on a simulation model freehand (Group SAFH), and then with a CAD/CAM surgical guide (Group SASG). In Group SB, another 30 students first performed guided (Group SBSG) and then freehand (Group SBFH). Ten instructors were also divided into Group IAFH/IASG (n = 5) and IBSG/IBFH (n = 5) following the same rules. The accuracy of implant placement was assessed by the coronal and apical distance (mm) and angular (°) deviations using the digital registration method. T tests and nonparametric tests were used to compare the results among different groups of approaches, experience and sequences. RESULTS: For students, the coronal and apical distance and the angular deviations were significantly lower in surgical guide group than freehand group in total and in learning freehand first subgroup, but for learning surgical guide first subgroup the apical distance deviation showed no significant difference between two approaches. For students, the angular deviation of freehand group was significantly lower in learning surgical guide first group than learning freehand first group. For instructors, the coronal and apical distance and angular deviations showed no significant difference between two approaches and two sequences. For freehand approach, the coronal and apical distance and the angular deviations were significantly higher in student group than instructor group, while not significantly different between two groups for surgical guide approach. CONCLUSIONS: For novices, using a surgical guide for the first implant placement may reduce the potential deviations compared with freehand surgery, and may reach a comparable accuracy with that of specialists. For simple single molar implantation, the surgical guide may not be significantly helpful for experienced specialists. BioMed Central 2023-06-27 /pmc/articles/PMC10294323/ /pubmed/37370027 http://dx.doi.org/10.1186/s12903-023-03116-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Li, Sha Yi, Chun Yu, Ziyang Wu, Aozhou Zhang, Yu Lin, Ye Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study |
title | Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study |
title_full | Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study |
title_fullStr | Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study |
title_full_unstemmed | Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study |
title_short | Accuracy assessment of implant placement with versus without a CAD/CAM surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study |
title_sort | accuracy assessment of implant placement with versus without a cad/cam surgical guide by novices versus specialists via the digital registration method: an in vitro randomized crossover study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10294323/ https://www.ncbi.nlm.nih.gov/pubmed/37370027 http://dx.doi.org/10.1186/s12903-023-03116-6 |
work_keys_str_mv | AT lisha accuracyassessmentofimplantplacementwithversuswithoutacadcamsurgicalguidebynovicesversusspecialistsviathedigitalregistrationmethodaninvitrorandomizedcrossoverstudy AT yichun accuracyassessmentofimplantplacementwithversuswithoutacadcamsurgicalguidebynovicesversusspecialistsviathedigitalregistrationmethodaninvitrorandomizedcrossoverstudy AT yuziyang accuracyassessmentofimplantplacementwithversuswithoutacadcamsurgicalguidebynovicesversusspecialistsviathedigitalregistrationmethodaninvitrorandomizedcrossoverstudy AT wuaozhou accuracyassessmentofimplantplacementwithversuswithoutacadcamsurgicalguidebynovicesversusspecialistsviathedigitalregistrationmethodaninvitrorandomizedcrossoverstudy AT zhangyu accuracyassessmentofimplantplacementwithversuswithoutacadcamsurgicalguidebynovicesversusspecialistsviathedigitalregistrationmethodaninvitrorandomizedcrossoverstudy AT linye accuracyassessmentofimplantplacementwithversuswithoutacadcamsurgicalguidebynovicesversusspecialistsviathedigitalregistrationmethodaninvitrorandomizedcrossoverstudy |