Cargando…
Enhancement of Antibacterial Properties, Surface Morphology and In Vitro Bioactivity of Hydroxyapatite-Zinc Oxide Nanocomposite Coating by Electrophoretic Deposition Technique
To develop medical-grade stainless-steel 316L implants that are biocompatible, non-toxic and antibacterial, such implants need to be coated with biomaterials to meet the current demanding properties of biomedical materials. Hydroxyapatite (HA) is commonly used as a bone implant coating due to its ex...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10295605/ https://www.ncbi.nlm.nih.gov/pubmed/37370624 http://dx.doi.org/10.3390/bioengineering10060693 |
_version_ | 1785063461205573632 |
---|---|
author | Akram, Waseem Zahid, Rumaisa Usama, Raja Muhammad AlQahtani, Salman Ali Dahshan, Mostafa Basit, Muhammad Abdul Yasir, Muhammad |
author_facet | Akram, Waseem Zahid, Rumaisa Usama, Raja Muhammad AlQahtani, Salman Ali Dahshan, Mostafa Basit, Muhammad Abdul Yasir, Muhammad |
author_sort | Akram, Waseem |
collection | PubMed |
description | To develop medical-grade stainless-steel 316L implants that are biocompatible, non-toxic and antibacterial, such implants need to be coated with biomaterials to meet the current demanding properties of biomedical materials. Hydroxyapatite (HA) is commonly used as a bone implant coating due to its excellent biocompatible properties. Zinc oxide (ZnO) nanoparticles are added to HA to increase its antibacterial and cohesion properties. The specimens were made of a stainless-steel grade 316 substrate coated with HA-ZnO using the electrophoretic deposition technique (EPD), and were subsequently characterized using scanning electron microscopy (SEM), energy dispersive X-ray (EDX), stylus profilometry, electrochemical corrosion testing and Fourier transform infrared (FTIR) spectroscopy. Additionally, cross-hatch tests, cell viability assays, antibacterial assessment and in vitro activity tests in simulated body fluid (SBF) were performed. The results showed that the HA-ZnO coating was uniform and resistant to corrosion in an acceptable range. FTIR confirmed the presence of HA-ZnO compositions, and the in vitro response and adhesion were in accordance with standard requirements for biomedical materials. Cell viability confirmed the viability of cells in an acceptable range (>70%). In addition, the antibacterial activity of ZnO was confirmed on Staphylococcus aureus. Thus, the HA-ZnO samples are recommended for biomedical applications. |
format | Online Article Text |
id | pubmed-10295605 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102956052023-06-28 Enhancement of Antibacterial Properties, Surface Morphology and In Vitro Bioactivity of Hydroxyapatite-Zinc Oxide Nanocomposite Coating by Electrophoretic Deposition Technique Akram, Waseem Zahid, Rumaisa Usama, Raja Muhammad AlQahtani, Salman Ali Dahshan, Mostafa Basit, Muhammad Abdul Yasir, Muhammad Bioengineering (Basel) Article To develop medical-grade stainless-steel 316L implants that are biocompatible, non-toxic and antibacterial, such implants need to be coated with biomaterials to meet the current demanding properties of biomedical materials. Hydroxyapatite (HA) is commonly used as a bone implant coating due to its excellent biocompatible properties. Zinc oxide (ZnO) nanoparticles are added to HA to increase its antibacterial and cohesion properties. The specimens were made of a stainless-steel grade 316 substrate coated with HA-ZnO using the electrophoretic deposition technique (EPD), and were subsequently characterized using scanning electron microscopy (SEM), energy dispersive X-ray (EDX), stylus profilometry, electrochemical corrosion testing and Fourier transform infrared (FTIR) spectroscopy. Additionally, cross-hatch tests, cell viability assays, antibacterial assessment and in vitro activity tests in simulated body fluid (SBF) were performed. The results showed that the HA-ZnO coating was uniform and resistant to corrosion in an acceptable range. FTIR confirmed the presence of HA-ZnO compositions, and the in vitro response and adhesion were in accordance with standard requirements for biomedical materials. Cell viability confirmed the viability of cells in an acceptable range (>70%). In addition, the antibacterial activity of ZnO was confirmed on Staphylococcus aureus. Thus, the HA-ZnO samples are recommended for biomedical applications. MDPI 2023-06-07 /pmc/articles/PMC10295605/ /pubmed/37370624 http://dx.doi.org/10.3390/bioengineering10060693 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Akram, Waseem Zahid, Rumaisa Usama, Raja Muhammad AlQahtani, Salman Ali Dahshan, Mostafa Basit, Muhammad Abdul Yasir, Muhammad Enhancement of Antibacterial Properties, Surface Morphology and In Vitro Bioactivity of Hydroxyapatite-Zinc Oxide Nanocomposite Coating by Electrophoretic Deposition Technique |
title | Enhancement of Antibacterial Properties, Surface Morphology and In Vitro Bioactivity of Hydroxyapatite-Zinc Oxide Nanocomposite Coating by Electrophoretic Deposition Technique |
title_full | Enhancement of Antibacterial Properties, Surface Morphology and In Vitro Bioactivity of Hydroxyapatite-Zinc Oxide Nanocomposite Coating by Electrophoretic Deposition Technique |
title_fullStr | Enhancement of Antibacterial Properties, Surface Morphology and In Vitro Bioactivity of Hydroxyapatite-Zinc Oxide Nanocomposite Coating by Electrophoretic Deposition Technique |
title_full_unstemmed | Enhancement of Antibacterial Properties, Surface Morphology and In Vitro Bioactivity of Hydroxyapatite-Zinc Oxide Nanocomposite Coating by Electrophoretic Deposition Technique |
title_short | Enhancement of Antibacterial Properties, Surface Morphology and In Vitro Bioactivity of Hydroxyapatite-Zinc Oxide Nanocomposite Coating by Electrophoretic Deposition Technique |
title_sort | enhancement of antibacterial properties, surface morphology and in vitro bioactivity of hydroxyapatite-zinc oxide nanocomposite coating by electrophoretic deposition technique |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10295605/ https://www.ncbi.nlm.nih.gov/pubmed/37370624 http://dx.doi.org/10.3390/bioengineering10060693 |
work_keys_str_mv | AT akramwaseem enhancementofantibacterialpropertiessurfacemorphologyandinvitrobioactivityofhydroxyapatitezincoxidenanocompositecoatingbyelectrophoreticdepositiontechnique AT zahidrumaisa enhancementofantibacterialpropertiessurfacemorphologyandinvitrobioactivityofhydroxyapatitezincoxidenanocompositecoatingbyelectrophoreticdepositiontechnique AT usamarajamuhammad enhancementofantibacterialpropertiessurfacemorphologyandinvitrobioactivityofhydroxyapatitezincoxidenanocompositecoatingbyelectrophoreticdepositiontechnique AT alqahtanisalmanali enhancementofantibacterialpropertiessurfacemorphologyandinvitrobioactivityofhydroxyapatitezincoxidenanocompositecoatingbyelectrophoreticdepositiontechnique AT dahshanmostafa enhancementofantibacterialpropertiessurfacemorphologyandinvitrobioactivityofhydroxyapatitezincoxidenanocompositecoatingbyelectrophoreticdepositiontechnique AT basitmuhammadabdul enhancementofantibacterialpropertiessurfacemorphologyandinvitrobioactivityofhydroxyapatitezincoxidenanocompositecoatingbyelectrophoreticdepositiontechnique AT yasirmuhammad enhancementofantibacterialpropertiessurfacemorphologyandinvitrobioactivityofhydroxyapatitezincoxidenanocompositecoatingbyelectrophoreticdepositiontechnique |