Cargando…

The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems

Dental-implant-supported reconstructions provide comfort and improvements in prosthetic function, adaptation, and stability over conventional treatment options. The objective of this study was to evaluate the effect of different denture cleansing solutions and their influence on the deterioration an...

Descripción completa

Detalles Bibliográficos
Autores principales: Monteiro, Sofia, Barreiros, Pedro, Mendes, Joana, Aroso, Carlos, Silva, António Sérgio, Mendes, José Manuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10295977/
https://www.ncbi.nlm.nih.gov/pubmed/37371776
http://dx.doi.org/10.3390/biomedicines11061681
_version_ 1785063548913713152
author Monteiro, Sofia
Barreiros, Pedro
Mendes, Joana
Aroso, Carlos
Silva, António Sérgio
Mendes, José Manuel
author_facet Monteiro, Sofia
Barreiros, Pedro
Mendes, Joana
Aroso, Carlos
Silva, António Sérgio
Mendes, José Manuel
author_sort Monteiro, Sofia
collection PubMed
description Dental-implant-supported reconstructions provide comfort and improvements in prosthetic function, adaptation, and stability over conventional treatment options. The objective of this study was to evaluate the effect of different denture cleansing solutions and their influence on the deterioration and loss of retention of overdenture attachments in a 12-month clinical-use simulation. In this way, ten specimens each of different brands of retentive caps made of Teflon (OT Equator(®) (Rhein83, Bologna, Italy), Locator(®) (Zest Anchors, Escondido, CA, USA), Kerator(®) (KJ Meditech, Gwangiu, Republic of Korea), and Locator R-Tx(®) (Zest Anchors, Escondido, CA, USA)) were immersed in five different cleaning solutions (Kukident(®) (P&G Tech, Oxford Parkway, UK), Benfix(®) (Laboratorios URGO S.L., Guipúzcoa, Spain), Corega(®) (Stafford Miller, Waterford, Ireland), and Protefix(®) (Neuhofer Weiche, Parchim, Germany)), and tap water was used as the control group, in a simulation that lasted 12 months. Data were analyzed using two-way ANOVA and a Tukey HSD. Furthermore, a Levene Test and Shapiro–Wilk tests were performed to assess the validation of the ANOVA assumptions. The statistical analysis was performed using R version 4.2.2 software with the significance level set to p < 0.05. There were significant statistical differences between the different manufacturers regarding the retention forces of the attachment’s retentive caps (F = 322.066, p < 0.001). For the cleaning solution groups, different statistical results between Kukident(®) (P&G Tech, Oxford Parkway, UK) (p < 0.05) and Benfix(®) (Laboratorios URGO S.L., Guipúzcoa, Spain) (p < 0.05) were observed. There were no significant statistical differences between Corega(®) (Stafford Miller, Ireland), Protefix(®) (Neuhofer Weiche, Parchim, Germany), and tap water, even though the retention forces decreased in all of them.
format Online
Article
Text
id pubmed-10295977
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102959772023-06-28 The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems Monteiro, Sofia Barreiros, Pedro Mendes, Joana Aroso, Carlos Silva, António Sérgio Mendes, José Manuel Biomedicines Article Dental-implant-supported reconstructions provide comfort and improvements in prosthetic function, adaptation, and stability over conventional treatment options. The objective of this study was to evaluate the effect of different denture cleansing solutions and their influence on the deterioration and loss of retention of overdenture attachments in a 12-month clinical-use simulation. In this way, ten specimens each of different brands of retentive caps made of Teflon (OT Equator(®) (Rhein83, Bologna, Italy), Locator(®) (Zest Anchors, Escondido, CA, USA), Kerator(®) (KJ Meditech, Gwangiu, Republic of Korea), and Locator R-Tx(®) (Zest Anchors, Escondido, CA, USA)) were immersed in five different cleaning solutions (Kukident(®) (P&G Tech, Oxford Parkway, UK), Benfix(®) (Laboratorios URGO S.L., Guipúzcoa, Spain), Corega(®) (Stafford Miller, Waterford, Ireland), and Protefix(®) (Neuhofer Weiche, Parchim, Germany)), and tap water was used as the control group, in a simulation that lasted 12 months. Data were analyzed using two-way ANOVA and a Tukey HSD. Furthermore, a Levene Test and Shapiro–Wilk tests were performed to assess the validation of the ANOVA assumptions. The statistical analysis was performed using R version 4.2.2 software with the significance level set to p < 0.05. There were significant statistical differences between the different manufacturers regarding the retention forces of the attachment’s retentive caps (F = 322.066, p < 0.001). For the cleaning solution groups, different statistical results between Kukident(®) (P&G Tech, Oxford Parkway, UK) (p < 0.05) and Benfix(®) (Laboratorios URGO S.L., Guipúzcoa, Spain) (p < 0.05) were observed. There were no significant statistical differences between Corega(®) (Stafford Miller, Ireland), Protefix(®) (Neuhofer Weiche, Parchim, Germany), and tap water, even though the retention forces decreased in all of them. MDPI 2023-06-09 /pmc/articles/PMC10295977/ /pubmed/37371776 http://dx.doi.org/10.3390/biomedicines11061681 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Monteiro, Sofia
Barreiros, Pedro
Mendes, Joana
Aroso, Carlos
Silva, António Sérgio
Mendes, José Manuel
The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems
title The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems
title_full The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems
title_fullStr The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems
title_full_unstemmed The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems
title_short The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems
title_sort influence of cleaning solutions on the retention of overdenture attachment systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10295977/
https://www.ncbi.nlm.nih.gov/pubmed/37371776
http://dx.doi.org/10.3390/biomedicines11061681
work_keys_str_mv AT monteirosofia theinfluenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT barreirospedro theinfluenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT mendesjoana theinfluenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT arosocarlos theinfluenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT silvaantoniosergio theinfluenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT mendesjosemanuel theinfluenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT monteirosofia influenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT barreirospedro influenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT mendesjoana influenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT arosocarlos influenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT silvaantoniosergio influenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems
AT mendesjosemanuel influenceofcleaningsolutionsontheretentionofoverdentureattachmentsystems