Cargando…

Quantifying Yeast Microtubules and Spindles Using the Toolkit for Automated Microtubule Tracking (TAMiT)

Fluorescently labeled proteins absorb and emit light, appearing as Gaussian spots in fluorescence imaging. When fluorescent tags are added to cytoskeletal polymers such as microtubules, a line of fluorescence and even non-linear structures results. While much progress has been made in techniques for...

Descripción completa

Detalles Bibliográficos
Autores principales: Ansari, Saad, Gergely, Zachary R., Flynn, Patrick, Li, Gabriella, Moore, Jeffrey K., Betterton, Meredith D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10296093/
https://www.ncbi.nlm.nih.gov/pubmed/37371519
http://dx.doi.org/10.3390/biom13060939
_version_ 1785063576171446272
author Ansari, Saad
Gergely, Zachary R.
Flynn, Patrick
Li, Gabriella
Moore, Jeffrey K.
Betterton, Meredith D.
author_facet Ansari, Saad
Gergely, Zachary R.
Flynn, Patrick
Li, Gabriella
Moore, Jeffrey K.
Betterton, Meredith D.
author_sort Ansari, Saad
collection PubMed
description Fluorescently labeled proteins absorb and emit light, appearing as Gaussian spots in fluorescence imaging. When fluorescent tags are added to cytoskeletal polymers such as microtubules, a line of fluorescence and even non-linear structures results. While much progress has been made in techniques for imaging and microscopy, image analysis is less well-developed. Current analysis of fluorescent microtubules uses either manual tools, such as kymographs, or automated software. As a result, our ability to quantify microtubule dynamics and organization from light microscopy remains limited. Despite the development of automated microtubule analysis tools for in vitro studies, analysis of images from cells often depends heavily on manual analysis. One of the main reasons for this disparity is the low signal-to-noise ratio in cells, where background fluorescence is typically higher than in reconstituted systems. Here, we present the Toolkit for Automated Microtubule Tracking (TAMiT), which automatically detects, optimizes, and tracks fluorescent microtubules in living yeast cells with sub-pixel accuracy. Using basic information about microtubule organization, TAMiT detects linear and curved polymers using a geometrical scanning technique. Images are fit via an optimization problem for the microtubule image parameters that are solved using non-linear least squares in Matlab. We benchmark our software using simulated images and show that it reliably detects microtubules, even at low signal-to-noise ratios. Then, we use TAMiT to measure monopolar spindle microtubule bundle number, length, and lifetime in a large dataset that includes several S. pombe mutants that affect microtubule dynamics and bundling. The results from the automated analysis are consistent with previous work and suggest a direct role for CLASP/Cls1 in bundling spindle microtubules. We also illustrate automated tracking of single curved astral microtubules in S. cerevisiae, with measurement of dynamic instability parameters. The results obtained with our fully-automated software are similar to results using hand-tracked measurements. Therefore, TAMiT can facilitate automated analysis of spindle and microtubule dynamics in yeast cells.
format Online
Article
Text
id pubmed-10296093
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102960932023-06-28 Quantifying Yeast Microtubules and Spindles Using the Toolkit for Automated Microtubule Tracking (TAMiT) Ansari, Saad Gergely, Zachary R. Flynn, Patrick Li, Gabriella Moore, Jeffrey K. Betterton, Meredith D. Biomolecules Article Fluorescently labeled proteins absorb and emit light, appearing as Gaussian spots in fluorescence imaging. When fluorescent tags are added to cytoskeletal polymers such as microtubules, a line of fluorescence and even non-linear structures results. While much progress has been made in techniques for imaging and microscopy, image analysis is less well-developed. Current analysis of fluorescent microtubules uses either manual tools, such as kymographs, or automated software. As a result, our ability to quantify microtubule dynamics and organization from light microscopy remains limited. Despite the development of automated microtubule analysis tools for in vitro studies, analysis of images from cells often depends heavily on manual analysis. One of the main reasons for this disparity is the low signal-to-noise ratio in cells, where background fluorescence is typically higher than in reconstituted systems. Here, we present the Toolkit for Automated Microtubule Tracking (TAMiT), which automatically detects, optimizes, and tracks fluorescent microtubules in living yeast cells with sub-pixel accuracy. Using basic information about microtubule organization, TAMiT detects linear and curved polymers using a geometrical scanning technique. Images are fit via an optimization problem for the microtubule image parameters that are solved using non-linear least squares in Matlab. We benchmark our software using simulated images and show that it reliably detects microtubules, even at low signal-to-noise ratios. Then, we use TAMiT to measure monopolar spindle microtubule bundle number, length, and lifetime in a large dataset that includes several S. pombe mutants that affect microtubule dynamics and bundling. The results from the automated analysis are consistent with previous work and suggest a direct role for CLASP/Cls1 in bundling spindle microtubules. We also illustrate automated tracking of single curved astral microtubules in S. cerevisiae, with measurement of dynamic instability parameters. The results obtained with our fully-automated software are similar to results using hand-tracked measurements. Therefore, TAMiT can facilitate automated analysis of spindle and microtubule dynamics in yeast cells. MDPI 2023-06-04 /pmc/articles/PMC10296093/ /pubmed/37371519 http://dx.doi.org/10.3390/biom13060939 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ansari, Saad
Gergely, Zachary R.
Flynn, Patrick
Li, Gabriella
Moore, Jeffrey K.
Betterton, Meredith D.
Quantifying Yeast Microtubules and Spindles Using the Toolkit for Automated Microtubule Tracking (TAMiT)
title Quantifying Yeast Microtubules and Spindles Using the Toolkit for Automated Microtubule Tracking (TAMiT)
title_full Quantifying Yeast Microtubules and Spindles Using the Toolkit for Automated Microtubule Tracking (TAMiT)
title_fullStr Quantifying Yeast Microtubules and Spindles Using the Toolkit for Automated Microtubule Tracking (TAMiT)
title_full_unstemmed Quantifying Yeast Microtubules and Spindles Using the Toolkit for Automated Microtubule Tracking (TAMiT)
title_short Quantifying Yeast Microtubules and Spindles Using the Toolkit for Automated Microtubule Tracking (TAMiT)
title_sort quantifying yeast microtubules and spindles using the toolkit for automated microtubule tracking (tamit)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10296093/
https://www.ncbi.nlm.nih.gov/pubmed/37371519
http://dx.doi.org/10.3390/biom13060939
work_keys_str_mv AT ansarisaad quantifyingyeastmicrotubulesandspindlesusingthetoolkitforautomatedmicrotubuletrackingtamit
AT gergelyzacharyr quantifyingyeastmicrotubulesandspindlesusingthetoolkitforautomatedmicrotubuletrackingtamit
AT flynnpatrick quantifyingyeastmicrotubulesandspindlesusingthetoolkitforautomatedmicrotubuletrackingtamit
AT ligabriella quantifyingyeastmicrotubulesandspindlesusingthetoolkitforautomatedmicrotubuletrackingtamit
AT moorejeffreyk quantifyingyeastmicrotubulesandspindlesusingthetoolkitforautomatedmicrotubuletrackingtamit
AT bettertonmeredithd quantifyingyeastmicrotubulesandspindlesusingthetoolkitforautomatedmicrotubuletrackingtamit