Cargando…

One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma

In this study, a simple, easy and convenient fluorescent sensing system for the detection of the vascular endothelial growth factor (VEGF) based on VEGF aptamers, aptamer-complementary fluorescence-labeled probe and streptavidin magnetic beads was developed in one single tube. The VEGF is the most i...

Descripción completa

Detalles Bibliográficos
Autores principales: Kou, Hwang-Shang, Lo, Shao-Tsung, Wang, Chun-Chi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10296741/
https://www.ncbi.nlm.nih.gov/pubmed/37366939
http://dx.doi.org/10.3390/bios13060574
_version_ 1785063721436971008
author Kou, Hwang-Shang
Lo, Shao-Tsung
Wang, Chun-Chi
author_facet Kou, Hwang-Shang
Lo, Shao-Tsung
Wang, Chun-Chi
author_sort Kou, Hwang-Shang
collection PubMed
description In this study, a simple, easy and convenient fluorescent sensing system for the detection of the vascular endothelial growth factor (VEGF) based on VEGF aptamers, aptamer-complementary fluorescence-labeled probe and streptavidin magnetic beads was developed in one single tube. The VEGF is the most important biomarker in cancer, and it is investigated that the serum VEGF level varied according to the different types and courses of cancers. Hence, efficient quantification of VEGF is able to improve the accuracy of cancer diagnoses and the precision of disease surveillance. In this research, the VEGF aptamer was designed to be able to bind with the VEGF by forming G-quadruplex secondary structures; then, the magnetic beads would capture the non-binding aptamers due to non-steric interference; and finally, the fluorescence-labeled probes were hybridized with the aptamers captured by the magnetic beads. Therefore, the fluorescent intensity in the supernatant would specifically reflect the present VEGF. After an overall optimization, the optimal conditions for the detection of VEGF were as followed, KCl, 50 μM; pH 7.0; aptamer, 0.1 μM; and magnetic beads, 10 μL (4 μg/μL). The VEGF could be well quantified within a range of 0.2-2.0 ng/mL in plasma, and the calibration curve possessed a good linearity (y = 1.0391x + 0.5471, r = 0.998). The detection limit (LOD) was calculated to be 0.0445 ng/mL according to the formula (LOD = 3.3 × σ/S). The specificity of this method was also investigated under the appearance of many other serum proteins, and the data showed good specificity in this aptasensor-based magnetic sensing system. This strategy provided a simple, sensitive and selective biosensing platform for the detection of serum VEGF. Finally, it was expected that this detection technique can be used to promote more clinical applications.
format Online
Article
Text
id pubmed-10296741
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102967412023-06-28 One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma Kou, Hwang-Shang Lo, Shao-Tsung Wang, Chun-Chi Biosensors (Basel) Article In this study, a simple, easy and convenient fluorescent sensing system for the detection of the vascular endothelial growth factor (VEGF) based on VEGF aptamers, aptamer-complementary fluorescence-labeled probe and streptavidin magnetic beads was developed in one single tube. The VEGF is the most important biomarker in cancer, and it is investigated that the serum VEGF level varied according to the different types and courses of cancers. Hence, efficient quantification of VEGF is able to improve the accuracy of cancer diagnoses and the precision of disease surveillance. In this research, the VEGF aptamer was designed to be able to bind with the VEGF by forming G-quadruplex secondary structures; then, the magnetic beads would capture the non-binding aptamers due to non-steric interference; and finally, the fluorescence-labeled probes were hybridized with the aptamers captured by the magnetic beads. Therefore, the fluorescent intensity in the supernatant would specifically reflect the present VEGF. After an overall optimization, the optimal conditions for the detection of VEGF were as followed, KCl, 50 μM; pH 7.0; aptamer, 0.1 μM; and magnetic beads, 10 μL (4 μg/μL). The VEGF could be well quantified within a range of 0.2-2.0 ng/mL in plasma, and the calibration curve possessed a good linearity (y = 1.0391x + 0.5471, r = 0.998). The detection limit (LOD) was calculated to be 0.0445 ng/mL according to the formula (LOD = 3.3 × σ/S). The specificity of this method was also investigated under the appearance of many other serum proteins, and the data showed good specificity in this aptasensor-based magnetic sensing system. This strategy provided a simple, sensitive and selective biosensing platform for the detection of serum VEGF. Finally, it was expected that this detection technique can be used to promote more clinical applications. MDPI 2023-05-24 /pmc/articles/PMC10296741/ /pubmed/37366939 http://dx.doi.org/10.3390/bios13060574 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kou, Hwang-Shang
Lo, Shao-Tsung
Wang, Chun-Chi
One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma
title One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma
title_full One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma
title_fullStr One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma
title_full_unstemmed One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma
title_short One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma
title_sort one single tube reaction of aptasensor-based magnetic sensing system for selective fluorescent detection of vegf in plasma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10296741/
https://www.ncbi.nlm.nih.gov/pubmed/37366939
http://dx.doi.org/10.3390/bios13060574
work_keys_str_mv AT kouhwangshang onesingletubereactionofaptasensorbasedmagneticsensingsystemforselectivefluorescentdetectionofvegfinplasma
AT loshaotsung onesingletubereactionofaptasensorbasedmagneticsensingsystemforselectivefluorescentdetectionofvegfinplasma
AT wangchunchi onesingletubereactionofaptasensorbasedmagneticsensingsystemforselectivefluorescentdetectionofvegfinplasma