Cargando…

Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma

PURPOSE: Measuring the spatial extent of defects may be advantageous in advanced glaucoma where conventional perimetric sensitivity measurements are unreliable. We test whether suprathreshold tests on a higher density grid can more efficiently map advanced visual field loss. METHODS: Data from 97 pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Denniss, Jonathan, McKendrick, Allison M., Turpin, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10297785/
https://www.ncbi.nlm.nih.gov/pubmed/37358492
http://dx.doi.org/10.1167/tvst.12.6.19
_version_ 1785063959161733120
author Denniss, Jonathan
McKendrick, Allison M.
Turpin, Andrew
author_facet Denniss, Jonathan
McKendrick, Allison M.
Turpin, Andrew
author_sort Denniss, Jonathan
collection PubMed
description PURPOSE: Measuring the spatial extent of defects may be advantageous in advanced glaucoma where conventional perimetric sensitivity measurements are unreliable. We test whether suprathreshold tests on a higher density grid can more efficiently map advanced visual field loss. METHODS: Data from 97 patients with mean deviation < –10 dB were used in simulations comparing two suprathreshold procedures (on a high-density 1.5° grid) to interpolated Full Threshold 24-2. Spatial binary search (SpaBS) presented 20-dB stimuli at locations bisecting seen/unseen points until the seen status of all neighbors matched or until tested points were adjacent. The SupraThreshold Adaptive Mapping Procedure (STAMP) presented 20-dB stimuli where entropy was maximal and modified the status of all points after each presentation, stopping after a fixed number of presentations (estimated as 50%–100% of the presentation number of a current procedure). RESULTS: With typical response errors, SpaBS had worse mean accuracy and repeatability than Full Threshold (both P < 0.0001). Compared to Full Threshold, mean accuracy (Full Threshold: median, 91%; interquartile range [IQR], 87%–94%) was slightly better with STAMP for all stopping criteria, although this was not statistically significant until 100% of conventional test presentations were used. Mean repeatability for STAMP was similar for all stopping criteria (P ≥ 0.02) compared to Full Threshold (Full Threshold: median, 89%; IQR, 82%–93%). CONCLUSIONS: STAMP accurately and repeatably maps the spatial extent of advanced visual field defects in as few as 50% of conventional perimetric test presentations. Further work is needed to test STAMP in human observers and in progressive loss. TRANSLATIONAL RELEVANCE: New perimetric approaches may improve information available for advanced glaucoma management and may potentially be more acceptable to patients.
format Online
Article
Text
id pubmed-10297785
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-102977852023-06-28 Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma Denniss, Jonathan McKendrick, Allison M. Turpin, Andrew Transl Vis Sci Technol Glaucoma PURPOSE: Measuring the spatial extent of defects may be advantageous in advanced glaucoma where conventional perimetric sensitivity measurements are unreliable. We test whether suprathreshold tests on a higher density grid can more efficiently map advanced visual field loss. METHODS: Data from 97 patients with mean deviation < –10 dB were used in simulations comparing two suprathreshold procedures (on a high-density 1.5° grid) to interpolated Full Threshold 24-2. Spatial binary search (SpaBS) presented 20-dB stimuli at locations bisecting seen/unseen points until the seen status of all neighbors matched or until tested points were adjacent. The SupraThreshold Adaptive Mapping Procedure (STAMP) presented 20-dB stimuli where entropy was maximal and modified the status of all points after each presentation, stopping after a fixed number of presentations (estimated as 50%–100% of the presentation number of a current procedure). RESULTS: With typical response errors, SpaBS had worse mean accuracy and repeatability than Full Threshold (both P < 0.0001). Compared to Full Threshold, mean accuracy (Full Threshold: median, 91%; interquartile range [IQR], 87%–94%) was slightly better with STAMP for all stopping criteria, although this was not statistically significant until 100% of conventional test presentations were used. Mean repeatability for STAMP was similar for all stopping criteria (P ≥ 0.02) compared to Full Threshold (Full Threshold: median, 89%; IQR, 82%–93%). CONCLUSIONS: STAMP accurately and repeatably maps the spatial extent of advanced visual field defects in as few as 50% of conventional perimetric test presentations. Further work is needed to test STAMP in human observers and in progressive loss. TRANSLATIONAL RELEVANCE: New perimetric approaches may improve information available for advanced glaucoma management and may potentially be more acceptable to patients. The Association for Research in Vision and Ophthalmology 2023-06-26 /pmc/articles/PMC10297785/ /pubmed/37358492 http://dx.doi.org/10.1167/tvst.12.6.19 Text en Copyright 2023 The Authors https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Glaucoma
Denniss, Jonathan
McKendrick, Allison M.
Turpin, Andrew
Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma
title Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma
title_full Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma
title_fullStr Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma
title_full_unstemmed Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma
title_short Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma
title_sort suprathreshold approaches to mapping the visual field in advanced glaucoma
topic Glaucoma
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10297785/
https://www.ncbi.nlm.nih.gov/pubmed/37358492
http://dx.doi.org/10.1167/tvst.12.6.19
work_keys_str_mv AT dennissjonathan suprathresholdapproachestomappingthevisualfieldinadvancedglaucoma
AT mckendrickallisonm suprathresholdapproachestomappingthevisualfieldinadvancedglaucoma
AT turpinandrew suprathresholdapproachestomappingthevisualfieldinadvancedglaucoma