Cargando…
Partner, Neighbor, Housekeeper and Dimension: 3D versus 2D Glomerular Co-Cultures Reveal Drawbacks of Currently Used Cell Culture Models
Signaling-pathway analyses and the investigation of gene responses to different stimuli are usually performed in 2D monocultures. However, within the glomerulus, cells grow in 3D and are involved in direct and paracrine interactions with different glomerular cell types. Thus, the results from 2D mon...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10299010/ https://www.ncbi.nlm.nih.gov/pubmed/37373531 http://dx.doi.org/10.3390/ijms241210384 |
_version_ | 1785064257580171264 |
---|---|
author | Rederer, Anna Rose, Victoria Krüger, René Schmittutz, Linda Swierzy, Izabela Fischer, Lena Thievessen, Ingo Bauer, Julian Friedrich, Oliver Schiffer, Mario Müller-Deile, Janina |
author_facet | Rederer, Anna Rose, Victoria Krüger, René Schmittutz, Linda Swierzy, Izabela Fischer, Lena Thievessen, Ingo Bauer, Julian Friedrich, Oliver Schiffer, Mario Müller-Deile, Janina |
author_sort | Rederer, Anna |
collection | PubMed |
description | Signaling-pathway analyses and the investigation of gene responses to different stimuli are usually performed in 2D monocultures. However, within the glomerulus, cells grow in 3D and are involved in direct and paracrine interactions with different glomerular cell types. Thus, the results from 2D monoculture experiments must be taken with caution. We cultured glomerular endothelial cells, podocytes and mesangial cells in 2D/3D monocultures and 2D/3D co-cultures and analyzed cell survival, self-assembly, gene expression, cell–cell interaction, and gene pathways using live/dead assay, time-lapse analysis, bulk-RNA sequencing, qPCR, and immunofluorescence staining. Without any need for scaffolds, 3D glomerular co-cultures self-organized into spheroids. Podocyte- and glomerular endothelial cell-specific markers and the extracellular matrix were increased in 3D co-cultures compared to 2D co-cultures. Housekeeping genes must be chosen wisely, as many genes used for the normalization of gene expression were themselves affected in 3D culture conditions. The transport of podocyte-derived VEGFA to glomerular endothelial cells confirmed intercellular crosstalk in the 3D co-culture models. The enhanced expression of genes important for glomerular function in 3D, compared to 2D, questions the reliability of currently used 2D monocultures. Hence, glomerular 3D co-cultures might be more suitable in the study of intercellular communication, disease modelling and drug screening ex vivo. |
format | Online Article Text |
id | pubmed-10299010 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102990102023-06-28 Partner, Neighbor, Housekeeper and Dimension: 3D versus 2D Glomerular Co-Cultures Reveal Drawbacks of Currently Used Cell Culture Models Rederer, Anna Rose, Victoria Krüger, René Schmittutz, Linda Swierzy, Izabela Fischer, Lena Thievessen, Ingo Bauer, Julian Friedrich, Oliver Schiffer, Mario Müller-Deile, Janina Int J Mol Sci Article Signaling-pathway analyses and the investigation of gene responses to different stimuli are usually performed in 2D monocultures. However, within the glomerulus, cells grow in 3D and are involved in direct and paracrine interactions with different glomerular cell types. Thus, the results from 2D monoculture experiments must be taken with caution. We cultured glomerular endothelial cells, podocytes and mesangial cells in 2D/3D monocultures and 2D/3D co-cultures and analyzed cell survival, self-assembly, gene expression, cell–cell interaction, and gene pathways using live/dead assay, time-lapse analysis, bulk-RNA sequencing, qPCR, and immunofluorescence staining. Without any need for scaffolds, 3D glomerular co-cultures self-organized into spheroids. Podocyte- and glomerular endothelial cell-specific markers and the extracellular matrix were increased in 3D co-cultures compared to 2D co-cultures. Housekeeping genes must be chosen wisely, as many genes used for the normalization of gene expression were themselves affected in 3D culture conditions. The transport of podocyte-derived VEGFA to glomerular endothelial cells confirmed intercellular crosstalk in the 3D co-culture models. The enhanced expression of genes important for glomerular function in 3D, compared to 2D, questions the reliability of currently used 2D monocultures. Hence, glomerular 3D co-cultures might be more suitable in the study of intercellular communication, disease modelling and drug screening ex vivo. MDPI 2023-06-20 /pmc/articles/PMC10299010/ /pubmed/37373531 http://dx.doi.org/10.3390/ijms241210384 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rederer, Anna Rose, Victoria Krüger, René Schmittutz, Linda Swierzy, Izabela Fischer, Lena Thievessen, Ingo Bauer, Julian Friedrich, Oliver Schiffer, Mario Müller-Deile, Janina Partner, Neighbor, Housekeeper and Dimension: 3D versus 2D Glomerular Co-Cultures Reveal Drawbacks of Currently Used Cell Culture Models |
title | Partner, Neighbor, Housekeeper and Dimension: 3D versus 2D Glomerular Co-Cultures Reveal Drawbacks of Currently Used Cell Culture Models |
title_full | Partner, Neighbor, Housekeeper and Dimension: 3D versus 2D Glomerular Co-Cultures Reveal Drawbacks of Currently Used Cell Culture Models |
title_fullStr | Partner, Neighbor, Housekeeper and Dimension: 3D versus 2D Glomerular Co-Cultures Reveal Drawbacks of Currently Used Cell Culture Models |
title_full_unstemmed | Partner, Neighbor, Housekeeper and Dimension: 3D versus 2D Glomerular Co-Cultures Reveal Drawbacks of Currently Used Cell Culture Models |
title_short | Partner, Neighbor, Housekeeper and Dimension: 3D versus 2D Glomerular Co-Cultures Reveal Drawbacks of Currently Used Cell Culture Models |
title_sort | partner, neighbor, housekeeper and dimension: 3d versus 2d glomerular co-cultures reveal drawbacks of currently used cell culture models |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10299010/ https://www.ncbi.nlm.nih.gov/pubmed/37373531 http://dx.doi.org/10.3390/ijms241210384 |
work_keys_str_mv | AT redereranna partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT rosevictoria partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT krugerrene partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT schmittutzlinda partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT swierzyizabela partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT fischerlena partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT thievesseningo partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT bauerjulian partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT friedricholiver partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT schiffermario partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels AT mullerdeilejanina partnerneighborhousekeeperanddimension3dversus2dglomerularcoculturesrevealdrawbacksofcurrentlyusedcellculturemodels |