Tape-Releasing Suture with “Long Loop” on Mid-Urethral Sling: A Novel Procedure for Management of Iatrogenic Urethral Obstruction
Background: To report our experiences of a tape-releasing suture with “long-loop” in women with iatrogenic urethral obstruction following the mid-urethral sling procedure. Methods: A total of 149 women underwent a tape-releasing suture with “Long Loop” during the operation. Post-void residual volume...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10299281/ https://www.ncbi.nlm.nih.gov/pubmed/37373634 http://dx.doi.org/10.3390/jcm12123938 |
_version_ | 1785064325185011712 |
---|---|
author | Long, Cheng-Yu Chang, Chieh-Yu Liu, Yi-Yin Loo, Zi-Xi Yeh, Chang-Lin Wu, Ming-Ping Lin, Kun-Ling Tang, Feng-Hsiang |
author_facet | Long, Cheng-Yu Chang, Chieh-Yu Liu, Yi-Yin Loo, Zi-Xi Yeh, Chang-Lin Wu, Ming-Ping Lin, Kun-Ling Tang, Feng-Hsiang |
author_sort | Long, Cheng-Yu |
collection | PubMed |
description | Background: To report our experiences of a tape-releasing suture with “long-loop” in women with iatrogenic urethral obstruction following the mid-urethral sling procedure. Methods: A total of 149 women underwent a tape-releasing suture with “Long Loop” during the operation. Post-void residual volume was evaluated after Foley removal. Lower urinary tract symptoms and urodynamic studies were assessed before and six months postoperatively. Results: Nine women out of 149 who underwent mid-urethral sling surgery were found to have iatrogenic urethral obstruction post-operatively based on their urinary symptoms and ultrasound findings. There was no apparent difference between tested groups in mid-urethral sling products and concomitant procedures. 77.8% had successful releases after the first Long-loop manipulation procedure, and 22.2% required two or more releases. However, the SUI cure rate is similar in groups receiving the Long-loop manipulation or not (88.9% and 87.1%, respectively). Conclusions: We are convinced of the practicability and efficacy of the tape-releasing suture “Long-loop.” We adopted subjective and objective means to evaluate both groups before and after a six-month follow-up. The Long-loop manipulation procedure can successfully resolve the iatrogenic urethral obstruction without compromising the effectiveness of mid-urethral sling for the treatment of SUI. |
format | Online Article Text |
id | pubmed-10299281 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102992812023-06-28 Tape-Releasing Suture with “Long Loop” on Mid-Urethral Sling: A Novel Procedure for Management of Iatrogenic Urethral Obstruction Long, Cheng-Yu Chang, Chieh-Yu Liu, Yi-Yin Loo, Zi-Xi Yeh, Chang-Lin Wu, Ming-Ping Lin, Kun-Ling Tang, Feng-Hsiang J Clin Med Article Background: To report our experiences of a tape-releasing suture with “long-loop” in women with iatrogenic urethral obstruction following the mid-urethral sling procedure. Methods: A total of 149 women underwent a tape-releasing suture with “Long Loop” during the operation. Post-void residual volume was evaluated after Foley removal. Lower urinary tract symptoms and urodynamic studies were assessed before and six months postoperatively. Results: Nine women out of 149 who underwent mid-urethral sling surgery were found to have iatrogenic urethral obstruction post-operatively based on their urinary symptoms and ultrasound findings. There was no apparent difference between tested groups in mid-urethral sling products and concomitant procedures. 77.8% had successful releases after the first Long-loop manipulation procedure, and 22.2% required two or more releases. However, the SUI cure rate is similar in groups receiving the Long-loop manipulation or not (88.9% and 87.1%, respectively). Conclusions: We are convinced of the practicability and efficacy of the tape-releasing suture “Long-loop.” We adopted subjective and objective means to evaluate both groups before and after a six-month follow-up. The Long-loop manipulation procedure can successfully resolve the iatrogenic urethral obstruction without compromising the effectiveness of mid-urethral sling for the treatment of SUI. MDPI 2023-06-09 /pmc/articles/PMC10299281/ /pubmed/37373634 http://dx.doi.org/10.3390/jcm12123938 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Long, Cheng-Yu Chang, Chieh-Yu Liu, Yi-Yin Loo, Zi-Xi Yeh, Chang-Lin Wu, Ming-Ping Lin, Kun-Ling Tang, Feng-Hsiang Tape-Releasing Suture with “Long Loop” on Mid-Urethral Sling: A Novel Procedure for Management of Iatrogenic Urethral Obstruction |
title | Tape-Releasing Suture with “Long Loop” on Mid-Urethral Sling: A Novel Procedure for Management of Iatrogenic Urethral Obstruction |
title_full | Tape-Releasing Suture with “Long Loop” on Mid-Urethral Sling: A Novel Procedure for Management of Iatrogenic Urethral Obstruction |
title_fullStr | Tape-Releasing Suture with “Long Loop” on Mid-Urethral Sling: A Novel Procedure for Management of Iatrogenic Urethral Obstruction |
title_full_unstemmed | Tape-Releasing Suture with “Long Loop” on Mid-Urethral Sling: A Novel Procedure for Management of Iatrogenic Urethral Obstruction |
title_short | Tape-Releasing Suture with “Long Loop” on Mid-Urethral Sling: A Novel Procedure for Management of Iatrogenic Urethral Obstruction |
title_sort | tape-releasing suture with “long loop” on mid-urethral sling: a novel procedure for management of iatrogenic urethral obstruction |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10299281/ https://www.ncbi.nlm.nih.gov/pubmed/37373634 http://dx.doi.org/10.3390/jcm12123938 |
work_keys_str_mv | AT longchengyu tapereleasingsuturewithlonglooponmidurethralslinganovelprocedureformanagementofiatrogenicurethralobstruction AT changchiehyu tapereleasingsuturewithlonglooponmidurethralslinganovelprocedureformanagementofiatrogenicurethralobstruction AT liuyiyin tapereleasingsuturewithlonglooponmidurethralslinganovelprocedureformanagementofiatrogenicurethralobstruction AT loozixi tapereleasingsuturewithlonglooponmidurethralslinganovelprocedureformanagementofiatrogenicurethralobstruction AT yehchanglin tapereleasingsuturewithlonglooponmidurethralslinganovelprocedureformanagementofiatrogenicurethralobstruction AT wumingping tapereleasingsuturewithlonglooponmidurethralslinganovelprocedureformanagementofiatrogenicurethralobstruction AT linkunling tapereleasingsuturewithlonglooponmidurethralslinganovelprocedureformanagementofiatrogenicurethralobstruction AT tangfenghsiang tapereleasingsuturewithlonglooponmidurethralslinganovelprocedureformanagementofiatrogenicurethralobstruction |