Cargando…

Simulation and Experimental Investigation of Balloon Folding and Inserting Performance for Angioplasty: A Comparison of Two Materials, Polyamide-12 and Pebax

Background: A balloon dilatation catheter is a vital tool in percutaneous transluminal angioplasty. Various factors, including the material used, influence the ability of different types of balloons to navigate through lesions during delivery. Objective: Thus far, numerical simulation studies compar...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Tao, Zhang, Zhuo, Wang, Wenyuan, Mao, Aijia, Chen, Yu, Xiong, Yan, Gao, Fei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10299601/
https://www.ncbi.nlm.nih.gov/pubmed/37367276
http://dx.doi.org/10.3390/jfb14060312
_version_ 1785064404157464576
author Li, Tao
Zhang, Zhuo
Wang, Wenyuan
Mao, Aijia
Chen, Yu
Xiong, Yan
Gao, Fei
author_facet Li, Tao
Zhang, Zhuo
Wang, Wenyuan
Mao, Aijia
Chen, Yu
Xiong, Yan
Gao, Fei
author_sort Li, Tao
collection PubMed
description Background: A balloon dilatation catheter is a vital tool in percutaneous transluminal angioplasty. Various factors, including the material used, influence the ability of different types of balloons to navigate through lesions during delivery. Objective: Thus far, numerical simulation studies comparing the impacts of different materials on the trackability of balloon catheters has been limited. This project seeks to unveil the underlying patterns more effectively by utilizing a highly realistic balloon-folding simulation method to compare the trackability of balloons made from different materials. Methods: Two materials, nylon-12 and Pebax, were examined for their insertion forces via a bench test and a numerical simulation. The simulation built a model identical to the bench test’s groove and simulated the balloon’s folding process prior to insertion to better replicate the experimental conditions. Results: In the bench test, nylon-12 demonstrated the highest insertion force, peaking at 0.866 N, significantly outstripping the 0.156 N force exhibited by the Pebax balloon. In the simulation, nylon-12 experienced a higher level of stress after folding, while Pebax had demonstrated a higher effective strain and surface energy density. In terms of insertion force, nylon-12 was higher than Pebax in specific areas. Conclusion: nylon-12 exerts greater pressure on the vessel wall in curved pathways when compared to Pebax. The simulated insertion forces of nylon-12 align with the experimental results. However, when using the same friction coefficient, the difference in insertion forces between the two materials is minimal. The numerical simulation method used in this study can be used for relevant research. This method can assess the performance of balloons made from diverse materials navigating curved paths and can yield more precise and detailed data feedback compared to benchtop experiments.
format Online
Article
Text
id pubmed-10299601
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102996012023-06-28 Simulation and Experimental Investigation of Balloon Folding and Inserting Performance for Angioplasty: A Comparison of Two Materials, Polyamide-12 and Pebax Li, Tao Zhang, Zhuo Wang, Wenyuan Mao, Aijia Chen, Yu Xiong, Yan Gao, Fei J Funct Biomater Article Background: A balloon dilatation catheter is a vital tool in percutaneous transluminal angioplasty. Various factors, including the material used, influence the ability of different types of balloons to navigate through lesions during delivery. Objective: Thus far, numerical simulation studies comparing the impacts of different materials on the trackability of balloon catheters has been limited. This project seeks to unveil the underlying patterns more effectively by utilizing a highly realistic balloon-folding simulation method to compare the trackability of balloons made from different materials. Methods: Two materials, nylon-12 and Pebax, were examined for their insertion forces via a bench test and a numerical simulation. The simulation built a model identical to the bench test’s groove and simulated the balloon’s folding process prior to insertion to better replicate the experimental conditions. Results: In the bench test, nylon-12 demonstrated the highest insertion force, peaking at 0.866 N, significantly outstripping the 0.156 N force exhibited by the Pebax balloon. In the simulation, nylon-12 experienced a higher level of stress after folding, while Pebax had demonstrated a higher effective strain and surface energy density. In terms of insertion force, nylon-12 was higher than Pebax in specific areas. Conclusion: nylon-12 exerts greater pressure on the vessel wall in curved pathways when compared to Pebax. The simulated insertion forces of nylon-12 align with the experimental results. However, when using the same friction coefficient, the difference in insertion forces between the two materials is minimal. The numerical simulation method used in this study can be used for relevant research. This method can assess the performance of balloons made from diverse materials navigating curved paths and can yield more precise and detailed data feedback compared to benchtop experiments. MDPI 2023-06-05 /pmc/articles/PMC10299601/ /pubmed/37367276 http://dx.doi.org/10.3390/jfb14060312 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Tao
Zhang, Zhuo
Wang, Wenyuan
Mao, Aijia
Chen, Yu
Xiong, Yan
Gao, Fei
Simulation and Experimental Investigation of Balloon Folding and Inserting Performance for Angioplasty: A Comparison of Two Materials, Polyamide-12 and Pebax
title Simulation and Experimental Investigation of Balloon Folding and Inserting Performance for Angioplasty: A Comparison of Two Materials, Polyamide-12 and Pebax
title_full Simulation and Experimental Investigation of Balloon Folding and Inserting Performance for Angioplasty: A Comparison of Two Materials, Polyamide-12 and Pebax
title_fullStr Simulation and Experimental Investigation of Balloon Folding and Inserting Performance for Angioplasty: A Comparison of Two Materials, Polyamide-12 and Pebax
title_full_unstemmed Simulation and Experimental Investigation of Balloon Folding and Inserting Performance for Angioplasty: A Comparison of Two Materials, Polyamide-12 and Pebax
title_short Simulation and Experimental Investigation of Balloon Folding and Inserting Performance for Angioplasty: A Comparison of Two Materials, Polyamide-12 and Pebax
title_sort simulation and experimental investigation of balloon folding and inserting performance for angioplasty: a comparison of two materials, polyamide-12 and pebax
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10299601/
https://www.ncbi.nlm.nih.gov/pubmed/37367276
http://dx.doi.org/10.3390/jfb14060312
work_keys_str_mv AT litao simulationandexperimentalinvestigationofballoonfoldingandinsertingperformanceforangioplastyacomparisonoftwomaterialspolyamide12andpebax
AT zhangzhuo simulationandexperimentalinvestigationofballoonfoldingandinsertingperformanceforangioplastyacomparisonoftwomaterialspolyamide12andpebax
AT wangwenyuan simulationandexperimentalinvestigationofballoonfoldingandinsertingperformanceforangioplastyacomparisonoftwomaterialspolyamide12andpebax
AT maoaijia simulationandexperimentalinvestigationofballoonfoldingandinsertingperformanceforangioplastyacomparisonoftwomaterialspolyamide12andpebax
AT chenyu simulationandexperimentalinvestigationofballoonfoldingandinsertingperformanceforangioplastyacomparisonoftwomaterialspolyamide12andpebax
AT xiongyan simulationandexperimentalinvestigationofballoonfoldingandinsertingperformanceforangioplastyacomparisonoftwomaterialspolyamide12andpebax
AT gaofei simulationandexperimentalinvestigationofballoonfoldingandinsertingperformanceforangioplastyacomparisonoftwomaterialspolyamide12andpebax