Cargando…

Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept

Objective. Current C-arm x-ray systems equipped with scintillator-based flat panel detectors (FPDs) lack sufficient low-contrast detectability and spectral, high-resolution capabilities much desired for certain interventional procedures. Semiconductor-based direct-conversion photon counting detector...

Descripción completa

Detalles Bibliográficos
Autores principales: Treb, Kevin, Hämisch, York, Ullberg, Christer, Zhang, Ran, Li, Ke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOP Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10299901/
https://www.ncbi.nlm.nih.gov/pubmed/37307849
http://dx.doi.org/10.1088/1361-6560/acddc7
_version_ 1785064468959461376
author Treb, Kevin
Hämisch, York
Ullberg, Christer
Zhang, Ran
Li, Ke
author_facet Treb, Kevin
Hämisch, York
Ullberg, Christer
Zhang, Ran
Li, Ke
author_sort Treb, Kevin
collection PubMed
description Objective. Current C-arm x-ray systems equipped with scintillator-based flat panel detectors (FPDs) lack sufficient low-contrast detectability and spectral, high-resolution capabilities much desired for certain interventional procedures. Semiconductor-based direct-conversion photon counting detectors (PCDs) offer these imaging capabilities, although the cost of full field-of-view (FOV) PCD is still too high at the moment. The purpose of this work was to present a hybrid photon counting-energy integrating FPD design as a cost-effective solution to high-quality interventional imaging. Approach. In the proposed hybrid detector design, the central scintillator and thin-film transistor elements in the FPD are replaced with a semiconductor PCD module to upgrade the imaging capabilities of the C-arm system while preserving the full FOV coverage. The central PCD module can be used for high-quality 2D and 3D region-of-interest imaging with improved spatial- and temporal-resolution as well as spectral resolving capability. An experimental proof-of-concept was conducted using a 30 × 2.5 cm(2) CdTe PCD and a 40 × 30 cm(2) CsI(Tl)-aSi(H) FPD. Main results. Phantom and in vivo animal studies show (1) improved visualization of small stent wires in both 2D and 3D images due to the better spatial resolution of the PCD; (2) dual-energy angiography imaging capability by using the spectral PCD; (3) better conspicuity of small peripheral iodinated vessels (contrast-to-noise ratio improvement range: (29%, 151%)); (4) the central PCD outputs can be fused seamlessly with the surrounding scintillator detector outputs to provide full field imaging: A post-processing chain was developed by leveraging the PCD’s spectral information to match the image contrast of the PCD images to the surrounding scintillator detector, followed by spatial filtering of the PCD image to match noise texture and spatial resolution. Significance. The hybrid FPD design provides a cost-effective option to upgrade C-arm systems with spectral and ultra-high resolution capabilities without interfering with the clinical need for full FOV imaging.
format Online
Article
Text
id pubmed-10299901
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher IOP Publishing
record_format MEDLINE/PubMed
spelling pubmed-102999012023-06-29 Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept Treb, Kevin Hämisch, York Ullberg, Christer Zhang, Ran Li, Ke Phys Med Biol Paper Objective. Current C-arm x-ray systems equipped with scintillator-based flat panel detectors (FPDs) lack sufficient low-contrast detectability and spectral, high-resolution capabilities much desired for certain interventional procedures. Semiconductor-based direct-conversion photon counting detectors (PCDs) offer these imaging capabilities, although the cost of full field-of-view (FOV) PCD is still too high at the moment. The purpose of this work was to present a hybrid photon counting-energy integrating FPD design as a cost-effective solution to high-quality interventional imaging. Approach. In the proposed hybrid detector design, the central scintillator and thin-film transistor elements in the FPD are replaced with a semiconductor PCD module to upgrade the imaging capabilities of the C-arm system while preserving the full FOV coverage. The central PCD module can be used for high-quality 2D and 3D region-of-interest imaging with improved spatial- and temporal-resolution as well as spectral resolving capability. An experimental proof-of-concept was conducted using a 30 × 2.5 cm(2) CdTe PCD and a 40 × 30 cm(2) CsI(Tl)-aSi(H) FPD. Main results. Phantom and in vivo animal studies show (1) improved visualization of small stent wires in both 2D and 3D images due to the better spatial resolution of the PCD; (2) dual-energy angiography imaging capability by using the spectral PCD; (3) better conspicuity of small peripheral iodinated vessels (contrast-to-noise ratio improvement range: (29%, 151%)); (4) the central PCD outputs can be fused seamlessly with the surrounding scintillator detector outputs to provide full field imaging: A post-processing chain was developed by leveraging the PCD’s spectral information to match the image contrast of the PCD images to the surrounding scintillator detector, followed by spatial filtering of the PCD image to match noise texture and spatial resolution. Significance. The hybrid FPD design provides a cost-effective option to upgrade C-arm systems with spectral and ultra-high resolution capabilities without interfering with the clinical need for full FOV imaging. IOP Publishing 2023-07-07 2023-06-28 /pmc/articles/PMC10299901/ /pubmed/37307849 http://dx.doi.org/10.1088/1361-6560/acddc7 Text en © 2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd https://creativecommons.org/licenses/by/4.0/Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/) . Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
spellingShingle Paper
Treb, Kevin
Hämisch, York
Ullberg, Christer
Zhang, Ran
Li, Ke
Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept
title Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept
title_full Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept
title_fullStr Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept
title_full_unstemmed Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept
title_short Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept
title_sort photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept
topic Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10299901/
https://www.ncbi.nlm.nih.gov/pubmed/37307849
http://dx.doi.org/10.1088/1361-6560/acddc7
work_keys_str_mv AT trebkevin photoncountingenergyintegratinghybridflatpaneldetectorsystemsforimageguidedinterventionsanexperimentalproofofconcept
AT hamischyork photoncountingenergyintegratinghybridflatpaneldetectorsystemsforimageguidedinterventionsanexperimentalproofofconcept
AT ullbergchrister photoncountingenergyintegratinghybridflatpaneldetectorsystemsforimageguidedinterventionsanexperimentalproofofconcept
AT zhangran photoncountingenergyintegratinghybridflatpaneldetectorsystemsforimageguidedinterventionsanexperimentalproofofconcept
AT like photoncountingenergyintegratinghybridflatpaneldetectorsystemsforimageguidedinterventionsanexperimentalproofofconcept