Value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps

This study was conducted to evaluate the effectiveness of the FLIR ONE PRO, a thermal imaging camera for smartphones, combined with handheld Doppler (HHD) in the localization of perforator arteries and to assess the efficacy of the FLIR ONE PRO in distinguishing perforators of the descending branch...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Weiwen, Yang, Yi, Jiang, Jiyong, Zhu, Qingtang, Qi, Jian, Qin, Bengang, Fan, Jingyuan, Fu, Ming, Li, Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10300357/
https://www.ncbi.nlm.nih.gov/pubmed/37389045
http://dx.doi.org/10.1016/j.heliyon.2023.e17372
_version_ 1785064570011779072
author Zhu, Weiwen
Yang, Yi
Jiang, Jiyong
Zhu, Qingtang
Qi, Jian
Qin, Bengang
Fan, Jingyuan
Fu, Ming
Li, Ping
author_facet Zhu, Weiwen
Yang, Yi
Jiang, Jiyong
Zhu, Qingtang
Qi, Jian
Qin, Bengang
Fan, Jingyuan
Fu, Ming
Li, Ping
author_sort Zhu, Weiwen
collection PubMed
description This study was conducted to evaluate the effectiveness of the FLIR ONE PRO, a thermal imaging camera for smartphones, combined with handheld Doppler (HHD) in the localization of perforator arteries and to assess the efficacy of the FLIR ONE PRO in distinguishing perforators of the descending branch of the lateral circumflex femoral artery (LCFA) from other perforators of the anterolateral thigh perforator (ALTP) flap. We enrolled 29 free perforator flaps from 22 patients in our study. Before surgery, dynamic infrared thermography was performed using a FLIR ONE PRO to visualize hotspots on the flaps. Subsequently, HHD was used to further determine the perforators under the hotspots, which were ultimately identified and confirmed through intraoperative findings. Additionally, infrared images of the ALTP flap were analyzed using FLIR Tools. The performances of the FLIR ONE PRO and FLIR ONE PRO + HHD groups were evaluated by comparing the intraoperative findings. Using FLIR ONE PRO + HHD, 119 hotspots and 106 perforators were identified during surgery. Using FLIR ONE PRO + HHD, sensitivity and positive predictive value were 97.87% and 88.46%, respectively, in the young (age≤45 years). In the elderly group (age>45 years), these percentages were 93.22% and 82.09%, respectively. In addition, we found that the FLIR ONE PRO could be useful for differentiating perforators in the descending branch of the LCFA from other perforators within 5 min. The results showed a sensitivity of 96.15%, a specificity of 98.9%, a positive predictive value of 96.15%, and a negative predictive value of 98.9%. Compared to using FLIR ONE PRO alone, the combined application of HHD and FLIR ONE PRO had a higher value in perforator localization by increasing the positive predictive value. The FLIR ONE PRO may have significance in the rapid prediction of perforators deriving from the descending branch of the LCFA.
format Online
Article
Text
id pubmed-10300357
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103003572023-06-29 Value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps Zhu, Weiwen Yang, Yi Jiang, Jiyong Zhu, Qingtang Qi, Jian Qin, Bengang Fan, Jingyuan Fu, Ming Li, Ping Heliyon Research Article This study was conducted to evaluate the effectiveness of the FLIR ONE PRO, a thermal imaging camera for smartphones, combined with handheld Doppler (HHD) in the localization of perforator arteries and to assess the efficacy of the FLIR ONE PRO in distinguishing perforators of the descending branch of the lateral circumflex femoral artery (LCFA) from other perforators of the anterolateral thigh perforator (ALTP) flap. We enrolled 29 free perforator flaps from 22 patients in our study. Before surgery, dynamic infrared thermography was performed using a FLIR ONE PRO to visualize hotspots on the flaps. Subsequently, HHD was used to further determine the perforators under the hotspots, which were ultimately identified and confirmed through intraoperative findings. Additionally, infrared images of the ALTP flap were analyzed using FLIR Tools. The performances of the FLIR ONE PRO and FLIR ONE PRO + HHD groups were evaluated by comparing the intraoperative findings. Using FLIR ONE PRO + HHD, 119 hotspots and 106 perforators were identified during surgery. Using FLIR ONE PRO + HHD, sensitivity and positive predictive value were 97.87% and 88.46%, respectively, in the young (age≤45 years). In the elderly group (age>45 years), these percentages were 93.22% and 82.09%, respectively. In addition, we found that the FLIR ONE PRO could be useful for differentiating perforators in the descending branch of the LCFA from other perforators within 5 min. The results showed a sensitivity of 96.15%, a specificity of 98.9%, a positive predictive value of 96.15%, and a negative predictive value of 98.9%. Compared to using FLIR ONE PRO alone, the combined application of HHD and FLIR ONE PRO had a higher value in perforator localization by increasing the positive predictive value. The FLIR ONE PRO may have significance in the rapid prediction of perforators deriving from the descending branch of the LCFA. Elsevier 2023-06-16 /pmc/articles/PMC10300357/ /pubmed/37389045 http://dx.doi.org/10.1016/j.heliyon.2023.e17372 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Zhu, Weiwen
Yang, Yi
Jiang, Jiyong
Zhu, Qingtang
Qi, Jian
Qin, Bengang
Fan, Jingyuan
Fu, Ming
Li, Ping
Value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps
title Value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps
title_full Value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps
title_fullStr Value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps
title_full_unstemmed Value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps
title_short Value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps
title_sort value of the combination of a smartphone-compatible infrared camera and a hand-held doppler ultrasound in preoperative localization of perforators in flaps
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10300357/
https://www.ncbi.nlm.nih.gov/pubmed/37389045
http://dx.doi.org/10.1016/j.heliyon.2023.e17372
work_keys_str_mv AT zhuweiwen valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps
AT yangyi valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps
AT jiangjiyong valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps
AT zhuqingtang valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps
AT qijian valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps
AT qinbengang valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps
AT fanjingyuan valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps
AT fuming valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps
AT liping valueofthecombinationofasmartphonecompatibleinfraredcameraandahandhelddopplerultrasoundinpreoperativelocalizationofperforatorsinflaps