Cargando…
Modified Lemaire Tenodesis Forces in Cadaveric Specimens Are Not Affected by Random Small-Scale Variations in the Femoral Insertion Point During Active Knee Joint Flexion-Extension
PURPOSE: To directly measure lateral extra-articular tenodesis (LET) forces supporting anterior cruciate ligament reconstruction (ACLR) during dynamic flexion-extension cycles induced by simulated active muscle forces, to investigate the influence of random surgical variation in the femoral LET inse...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10300583/ https://www.ncbi.nlm.nih.gov/pubmed/37388897 http://dx.doi.org/10.1016/j.asmr.2023.04.007 |
Sumario: | PURPOSE: To directly measure lateral extra-articular tenodesis (LET) forces supporting anterior cruciate ligament reconstruction (ACLR) during dynamic flexion-extension cycles induced by simulated active muscle forces, to investigate the influence of random surgical variation in the femoral LET insertion point around the target insertion position, and to determine potential changes to the extension behavior of the knee joint in a cadaveric model. METHODS: After iatrogenic anterior cruciate ligament deficiency and simulated anterolateral rotatory instability, 7 fresh-frozen cadaveric knee joints were treated with isolated ACLR followed by combined ACLR-LET. The specimens were tested on a knee joint test bench during active dynamic flexion-extension with simulated muscle forces. LET forces and the degree of knee joint extension were measured. Random variation in the LET insertion point around the target insertion position was postoperatively quantified by computed tomography. RESULTS: In extension, the median LET force increased to 39 ± 2 N (95% confidence interval [CI], 36 to 40 N). In flexion over 70°, the LET was offloaded (2 ± 1 N; 95% CI, 0 to 2 N). In this study, small-scale surgical variation in the femoral LET insertion point around the target position had a negligible effect on the graft forces measured. We detected no difference in the degree of knee joint extension after combined ACLR-LET (median, 1.0° ± 3.0°; 95% CI, −6.2° to 5.2°) in comparison with isolated ACLR (median, 1.1° ± 3.3°; 95% CI, −6.7° to 6.1°; P = .62). CONCLUSIONS: LET forces in combined ACLR-LET increased to a limited extent during active knee joint flexion-extension independent of small-scale variation around 1 specific target insertion point. Combined ACLR-LET did not change knee joint extension in comparison with isolated ACLR under the testing conditions used in this biomechanical study. CLINICAL RELEVANCE: Low LET forces can be expected during flexion-extension of the knee joint. Small-scale deviations in the femoral LET insertion point around the target insertion position in the modified Lemaire technique might have a minor effect on graft forces during active flexion-extension. |
---|