Cargando…

Rapid Calibration of Nanoliter per Second Flow Rate by Image Processing Technology

The need for high-precision microflow control is increasingly evident across various fields. For instance, microsatellites employed in gravitational wave detection require flow supply systems with a high accuracy of up to 0.1 nL/s to achieve on-orbit attitude control and orbit control. However, conv...

Descripción completa

Detalles Bibliográficos
Autores principales: Luo, Jiawei, Yang, Cheng, Shen, Yan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301103/
https://www.ncbi.nlm.nih.gov/pubmed/37374775
http://dx.doi.org/10.3390/mi14061189
_version_ 1785064733346365440
author Luo, Jiawei
Yang, Cheng
Shen, Yan
author_facet Luo, Jiawei
Yang, Cheng
Shen, Yan
author_sort Luo, Jiawei
collection PubMed
description The need for high-precision microflow control is increasingly evident across various fields. For instance, microsatellites employed in gravitational wave detection require flow supply systems with a high accuracy of up to 0.1 nL/s to achieve on-orbit attitude control and orbit control. However, conventional flow sensors are unable to provide the necessary precision in the nanoliter per second range, and thus, alternative methods are required. In this study, we propose the use of image processing technology for rapid microflow calibration. Our method involves capturing images of the droplets at the outlet of the flow supply system to rapidly obtain the flow rate, and we used the gravimetric method to verify the accuracy of our approach. We conducted several microflow calibration experiments within the 1.5 nL/s range and demonstrated that image processing technology can achieve the desired accuracy of 0.1 nL/s while saving more than two-thirds of the time required to obtain the flow rate within an acceptable margin of error compared to the gravimetric method. Our study presents an efficient and innovative approach to addressing the challenges of measuring microflows with high precision, particularly in the nanoliter per second range, and has the potential for widespread applications in various fields.
format Online
Article
Text
id pubmed-10301103
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103011032023-06-29 Rapid Calibration of Nanoliter per Second Flow Rate by Image Processing Technology Luo, Jiawei Yang, Cheng Shen, Yan Micromachines (Basel) Article The need for high-precision microflow control is increasingly evident across various fields. For instance, microsatellites employed in gravitational wave detection require flow supply systems with a high accuracy of up to 0.1 nL/s to achieve on-orbit attitude control and orbit control. However, conventional flow sensors are unable to provide the necessary precision in the nanoliter per second range, and thus, alternative methods are required. In this study, we propose the use of image processing technology for rapid microflow calibration. Our method involves capturing images of the droplets at the outlet of the flow supply system to rapidly obtain the flow rate, and we used the gravimetric method to verify the accuracy of our approach. We conducted several microflow calibration experiments within the 1.5 nL/s range and demonstrated that image processing technology can achieve the desired accuracy of 0.1 nL/s while saving more than two-thirds of the time required to obtain the flow rate within an acceptable margin of error compared to the gravimetric method. Our study presents an efficient and innovative approach to addressing the challenges of measuring microflows with high precision, particularly in the nanoliter per second range, and has the potential for widespread applications in various fields. MDPI 2023-06-02 /pmc/articles/PMC10301103/ /pubmed/37374775 http://dx.doi.org/10.3390/mi14061189 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Luo, Jiawei
Yang, Cheng
Shen, Yan
Rapid Calibration of Nanoliter per Second Flow Rate by Image Processing Technology
title Rapid Calibration of Nanoliter per Second Flow Rate by Image Processing Technology
title_full Rapid Calibration of Nanoliter per Second Flow Rate by Image Processing Technology
title_fullStr Rapid Calibration of Nanoliter per Second Flow Rate by Image Processing Technology
title_full_unstemmed Rapid Calibration of Nanoliter per Second Flow Rate by Image Processing Technology
title_short Rapid Calibration of Nanoliter per Second Flow Rate by Image Processing Technology
title_sort rapid calibration of nanoliter per second flow rate by image processing technology
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301103/
https://www.ncbi.nlm.nih.gov/pubmed/37374775
http://dx.doi.org/10.3390/mi14061189
work_keys_str_mv AT luojiawei rapidcalibrationofnanoliterpersecondflowratebyimageprocessingtechnology
AT yangcheng rapidcalibrationofnanoliterpersecondflowratebyimageprocessingtechnology
AT shenyan rapidcalibrationofnanoliterpersecondflowratebyimageprocessingtechnology