Cargando…

X-ray Computed Tomography (CT) to Scan the Structure and Characterize the Mud Cake Incorporated with Various Magnetic NPs Concentration: An Application to Evaluate the Wellbore Stability and Formation Damage

The X-ray computed tomography method has provided unrivalled data about the characterization and evolution of the internal/external structure of materials by analyzing CTN and non-destructive imaging approach. Applying this method on the appropriate drilling-fluid ingredients plays a significant rol...

Descripción completa

Detalles Bibliográficos
Autores principales: Faisal, Rasan Sarbast, Salih, Namam M., Kamal, Ibtisam, Préat, Alain
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301298/
https://www.ncbi.nlm.nih.gov/pubmed/37368274
http://dx.doi.org/10.3390/nano13121843
_version_ 1785064778634362880
author Faisal, Rasan Sarbast
Salih, Namam M.
Kamal, Ibtisam
Préat, Alain
author_facet Faisal, Rasan Sarbast
Salih, Namam M.
Kamal, Ibtisam
Préat, Alain
author_sort Faisal, Rasan Sarbast
collection PubMed
description The X-ray computed tomography method has provided unrivalled data about the characterization and evolution of the internal/external structure of materials by analyzing CTN and non-destructive imaging approach. Applying this method on the appropriate drilling-fluid ingredients plays a significant role in generating proper mud cake quality to stabilize wellbore, and avoid formation damage and filtration loss by preventing drilling fluid invasion into the formation. In this study, smart-water drilling mud containing different concentrations of magnetite nanoparticles (MNPs) was used to assess the filtration loss properties and formation impairment. Conventional static filter press, non-destructive X-ray computed tomography (CT) scan images and high-resolution quantitative measurement of CT number method were used to estimate the filtrate volume and characterize the filter cake layers, hence evaluating the reservoir damage through hundreds of merged images. The CT scan data were combined with the HIPAX and Radiant viewer digital image processing. The variation in CT number of mud cake samples under different concentrations of MNPs and without MNPs concentration were analyzed, and hundreds of 3D images as a cross-sectional profile were used. This paper highlights the importance of MNPs property in terms of minimizing filtration volume and improving mud cake quality and thickness, and hence improving the wellbore stability. From the results, a notable reduction of filtrate drilling mud volume and mud cake thickness to 40.9% and 46.6%, respectively, were recorded for drilling fluids incorporated with 0.92 wt.% of MNPs. However, this study asserts that optimal MNPs should be implemented to guarantee the best filtration property. As confirmed from the results, increasing the MNPs concentration beyond the optimal value (up to 2 wt.%) increased the filtrate volume and mud cake thickness by 3.23 and 33.3%, respectively. CT scan profile images show two layers of mud cake produced from water-based drilling fluids possessing 0.92 wt.% MNPs. The latter concentration was found to be the optimal additive of MNPs as it caused a decrease in filtration volume, mud cake thickness, and pore spaces within the structure of the mud cake. Using the optimum MNPs, the CT number (CTN) shows a high CTN and density material, and uniform compacted thin mud cake structure (0.75 mm). The produced thin mud cake layer reveals the precipitation or exchange of elemental/mineral composition during fluid-solid interaction. These results confirm that MNPs could help in avoiding or reducing the formation damage, driving away drilling fluid from the formation, and improving borehole stability.
format Online
Article
Text
id pubmed-10301298
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103012982023-06-29 X-ray Computed Tomography (CT) to Scan the Structure and Characterize the Mud Cake Incorporated with Various Magnetic NPs Concentration: An Application to Evaluate the Wellbore Stability and Formation Damage Faisal, Rasan Sarbast Salih, Namam M. Kamal, Ibtisam Préat, Alain Nanomaterials (Basel) Article The X-ray computed tomography method has provided unrivalled data about the characterization and evolution of the internal/external structure of materials by analyzing CTN and non-destructive imaging approach. Applying this method on the appropriate drilling-fluid ingredients plays a significant role in generating proper mud cake quality to stabilize wellbore, and avoid formation damage and filtration loss by preventing drilling fluid invasion into the formation. In this study, smart-water drilling mud containing different concentrations of magnetite nanoparticles (MNPs) was used to assess the filtration loss properties and formation impairment. Conventional static filter press, non-destructive X-ray computed tomography (CT) scan images and high-resolution quantitative measurement of CT number method were used to estimate the filtrate volume and characterize the filter cake layers, hence evaluating the reservoir damage through hundreds of merged images. The CT scan data were combined with the HIPAX and Radiant viewer digital image processing. The variation in CT number of mud cake samples under different concentrations of MNPs and without MNPs concentration were analyzed, and hundreds of 3D images as a cross-sectional profile were used. This paper highlights the importance of MNPs property in terms of minimizing filtration volume and improving mud cake quality and thickness, and hence improving the wellbore stability. From the results, a notable reduction of filtrate drilling mud volume and mud cake thickness to 40.9% and 46.6%, respectively, were recorded for drilling fluids incorporated with 0.92 wt.% of MNPs. However, this study asserts that optimal MNPs should be implemented to guarantee the best filtration property. As confirmed from the results, increasing the MNPs concentration beyond the optimal value (up to 2 wt.%) increased the filtrate volume and mud cake thickness by 3.23 and 33.3%, respectively. CT scan profile images show two layers of mud cake produced from water-based drilling fluids possessing 0.92 wt.% MNPs. The latter concentration was found to be the optimal additive of MNPs as it caused a decrease in filtration volume, mud cake thickness, and pore spaces within the structure of the mud cake. Using the optimum MNPs, the CT number (CTN) shows a high CTN and density material, and uniform compacted thin mud cake structure (0.75 mm). The produced thin mud cake layer reveals the precipitation or exchange of elemental/mineral composition during fluid-solid interaction. These results confirm that MNPs could help in avoiding or reducing the formation damage, driving away drilling fluid from the formation, and improving borehole stability. MDPI 2023-06-12 /pmc/articles/PMC10301298/ /pubmed/37368274 http://dx.doi.org/10.3390/nano13121843 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Faisal, Rasan Sarbast
Salih, Namam M.
Kamal, Ibtisam
Préat, Alain
X-ray Computed Tomography (CT) to Scan the Structure and Characterize the Mud Cake Incorporated with Various Magnetic NPs Concentration: An Application to Evaluate the Wellbore Stability and Formation Damage
title X-ray Computed Tomography (CT) to Scan the Structure and Characterize the Mud Cake Incorporated with Various Magnetic NPs Concentration: An Application to Evaluate the Wellbore Stability and Formation Damage
title_full X-ray Computed Tomography (CT) to Scan the Structure and Characterize the Mud Cake Incorporated with Various Magnetic NPs Concentration: An Application to Evaluate the Wellbore Stability and Formation Damage
title_fullStr X-ray Computed Tomography (CT) to Scan the Structure and Characterize the Mud Cake Incorporated with Various Magnetic NPs Concentration: An Application to Evaluate the Wellbore Stability and Formation Damage
title_full_unstemmed X-ray Computed Tomography (CT) to Scan the Structure and Characterize the Mud Cake Incorporated with Various Magnetic NPs Concentration: An Application to Evaluate the Wellbore Stability and Formation Damage
title_short X-ray Computed Tomography (CT) to Scan the Structure and Characterize the Mud Cake Incorporated with Various Magnetic NPs Concentration: An Application to Evaluate the Wellbore Stability and Formation Damage
title_sort x-ray computed tomography (ct) to scan the structure and characterize the mud cake incorporated with various magnetic nps concentration: an application to evaluate the wellbore stability and formation damage
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301298/
https://www.ncbi.nlm.nih.gov/pubmed/37368274
http://dx.doi.org/10.3390/nano13121843
work_keys_str_mv AT faisalrasansarbast xraycomputedtomographycttoscanthestructureandcharacterizethemudcakeincorporatedwithvariousmagneticnpsconcentrationanapplicationtoevaluatethewellborestabilityandformationdamage
AT salihnamamm xraycomputedtomographycttoscanthestructureandcharacterizethemudcakeincorporatedwithvariousmagneticnpsconcentrationanapplicationtoevaluatethewellborestabilityandformationdamage
AT kamalibtisam xraycomputedtomographycttoscanthestructureandcharacterizethemudcakeincorporatedwithvariousmagneticnpsconcentrationanapplicationtoevaluatethewellborestabilityandformationdamage
AT preatalain xraycomputedtomographycttoscanthestructureandcharacterizethemudcakeincorporatedwithvariousmagneticnpsconcentrationanapplicationtoevaluatethewellborestabilityandformationdamage