Cargando…
Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer
This study presents a methodology that combines experimental tests and the finite element method, which is able to analyse the influence of the geometry on the mechanical behaviour of stents made of bioabsorbable polymer PLA (PolyLactic Acid) during their expansion in the treatment of coarctation of...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301593/ https://www.ncbi.nlm.nih.gov/pubmed/37374585 http://dx.doi.org/10.3390/ma16124403 |
_version_ | 1785064848941383680 |
---|---|
author | dos Santos, Flávio José Hernandez, Bruno Agostinho Santos, Rosana Machado, Marcel Souza, Mateus Capello Sousa, Edson A. Andrade, Aron |
author_facet | dos Santos, Flávio José Hernandez, Bruno Agostinho Santos, Rosana Machado, Marcel Souza, Mateus Capello Sousa, Edson A. Andrade, Aron |
author_sort | dos Santos, Flávio José |
collection | PubMed |
description | This study presents a methodology that combines experimental tests and the finite element method, which is able to analyse the influence of the geometry on the mechanical behaviour of stents made of bioabsorbable polymer PLA (PolyLactic Acid) during their expansion in the treatment of coarctation of the aorta (CoA). Tensile tests with standardized specimen samples were conducted to determine the properties of a 3D-printed PLA. A finite element model of a new stent prototype was generated from CAD files. A rigid cylinder simulating the expansion balloon was also created to simulate the stent opening performance. A tensile test with 3D-printed customized stent specimens was performed to validate the FE stent model. Stent performance was evaluated in terms of elastic return, recoil, and stress levels. The 3D-printed PLA presented an elastic modulus of 1.5 GPa and a yield strength of 30.6 MPa, lower than non-3D-printed PLA. It can also be inferred that crimping had little effect on stent circular recoil performance, as the difference between the two scenarios was on average 1.81%. For an expansion of diameters ranging from 12 mm to 15 mm, as the maximum opening diameter increases, the recoil levels decrease, ranging from 10 to 16.75% within the reported range. These results point out the importance of testing the 3D-printed PLA under the conditions of using it to access its material properties; the results also indicate that the crimping process could be disregarded in simulations to obtain fast results with lower computational cost and that new proposed stent geometry made of PLA might be suitable for use in CoA treatments—the approach that has not been applied before. The next steps will be to simulate the opening of an aorta vessel using this geometry. |
format | Online Article Text |
id | pubmed-10301593 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103015932023-06-29 Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer dos Santos, Flávio José Hernandez, Bruno Agostinho Santos, Rosana Machado, Marcel Souza, Mateus Capello Sousa, Edson A. Andrade, Aron Materials (Basel) Article This study presents a methodology that combines experimental tests and the finite element method, which is able to analyse the influence of the geometry on the mechanical behaviour of stents made of bioabsorbable polymer PLA (PolyLactic Acid) during their expansion in the treatment of coarctation of the aorta (CoA). Tensile tests with standardized specimen samples were conducted to determine the properties of a 3D-printed PLA. A finite element model of a new stent prototype was generated from CAD files. A rigid cylinder simulating the expansion balloon was also created to simulate the stent opening performance. A tensile test with 3D-printed customized stent specimens was performed to validate the FE stent model. Stent performance was evaluated in terms of elastic return, recoil, and stress levels. The 3D-printed PLA presented an elastic modulus of 1.5 GPa and a yield strength of 30.6 MPa, lower than non-3D-printed PLA. It can also be inferred that crimping had little effect on stent circular recoil performance, as the difference between the two scenarios was on average 1.81%. For an expansion of diameters ranging from 12 mm to 15 mm, as the maximum opening diameter increases, the recoil levels decrease, ranging from 10 to 16.75% within the reported range. These results point out the importance of testing the 3D-printed PLA under the conditions of using it to access its material properties; the results also indicate that the crimping process could be disregarded in simulations to obtain fast results with lower computational cost and that new proposed stent geometry made of PLA might be suitable for use in CoA treatments—the approach that has not been applied before. The next steps will be to simulate the opening of an aorta vessel using this geometry. MDPI 2023-06-15 /pmc/articles/PMC10301593/ /pubmed/37374585 http://dx.doi.org/10.3390/ma16124403 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article dos Santos, Flávio José Hernandez, Bruno Agostinho Santos, Rosana Machado, Marcel Souza, Mateus Capello Sousa, Edson A. Andrade, Aron Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer |
title | Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer |
title_full | Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer |
title_fullStr | Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer |
title_full_unstemmed | Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer |
title_short | Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer |
title_sort | bioabsorbable polymeric stent for the treatment of coarctation of the aorta (coa) in children: a methodology to evaluate the design and mechanical properties of pla polymer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301593/ https://www.ncbi.nlm.nih.gov/pubmed/37374585 http://dx.doi.org/10.3390/ma16124403 |
work_keys_str_mv | AT dossantosflaviojose bioabsorbablepolymericstentforthetreatmentofcoarctationoftheaortacoainchildrenamethodologytoevaluatethedesignandmechanicalpropertiesofplapolymer AT hernandezbrunoagostinho bioabsorbablepolymericstentforthetreatmentofcoarctationoftheaortacoainchildrenamethodologytoevaluatethedesignandmechanicalpropertiesofplapolymer AT santosrosana bioabsorbablepolymericstentforthetreatmentofcoarctationoftheaortacoainchildrenamethodologytoevaluatethedesignandmechanicalpropertiesofplapolymer AT machadomarcel bioabsorbablepolymericstentforthetreatmentofcoarctationoftheaortacoainchildrenamethodologytoevaluatethedesignandmechanicalpropertiesofplapolymer AT souzamateus bioabsorbablepolymericstentforthetreatmentofcoarctationoftheaortacoainchildrenamethodologytoevaluatethedesignandmechanicalpropertiesofplapolymer AT capellosousaedsona bioabsorbablepolymericstentforthetreatmentofcoarctationoftheaortacoainchildrenamethodologytoevaluatethedesignandmechanicalpropertiesofplapolymer AT andradearon bioabsorbablepolymericstentforthetreatmentofcoarctationoftheaortacoainchildrenamethodologytoevaluatethedesignandmechanicalpropertiesofplapolymer |