Cargando…
All surgical supra-annular aortic valvar tissue prostheses are labelled too large
OBJECTIVES: Surgical supra-annular aortic valvar tissue prostheses are labelled in an inconsistent and confusing manner. If the replaced valve is too small for a given patient, the risk of patient-prosthesis mismatch is increased, which is associated with the risk of morbidity and mortality. The lab...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301699/ https://www.ncbi.nlm.nih.gov/pubmed/37184926 http://dx.doi.org/10.1093/icvts/ivad076 |
_version_ | 1785064874373545984 |
---|---|
author | van Boxtel, Astrid Gerritje Maria Mariani, Massimo Alessandro Ebels, Tjark |
author_facet | van Boxtel, Astrid Gerritje Maria Mariani, Massimo Alessandro Ebels, Tjark |
author_sort | van Boxtel, Astrid Gerritje Maria |
collection | PubMed |
description | OBJECTIVES: Surgical supra-annular aortic valvar tissue prostheses are labelled in an inconsistent and confusing manner. If the replaced valve is too small for a given patient, the risk of patient-prosthesis mismatch is increased, which is associated with the risk of morbidity and mortality. The labelled diameter (LD) of these valves should coincide with the inflow orifice diameter (IOD). Therefore, our goal was to measure all relevant IODs. METHODS: Valvar design was assessed in terms of the intended position of the valve in relation to the patient’s annulus. The IODs of all available supra-annular aortic valvar prostheses were measured using a conical gauge. The IODs were compared to the LDs. We searched for instructions for use, websites, packing boxes and regulatory institutions involved in the process. RESULTS: Eight valve models from 4 manufacturers were included. None of these valves were clearly labelled as supra-annular on the packing box, although for 3, the supra-annular label could be found in the written specifications. All valves had an IOD smaller than their LD, with a median difference of 15% (range: 4%–25%). The departure from LD differed per valve model and valve size. CONCLUSIONS: Valve packages should be labelled accurately and clearly so that surgeons can make a well-informed choice. Currently essential information is missing because the intended position in relation to the annulus is not consistently marked on the packing boxes, and valve sizes are labelled incorrectly. We propose a change for the better: relabel all valves according to their true IOD in a structured manner. |
format | Online Article Text |
id | pubmed-10301699 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-103016992023-06-29 All surgical supra-annular aortic valvar tissue prostheses are labelled too large van Boxtel, Astrid Gerritje Maria Mariani, Massimo Alessandro Ebels, Tjark Interdiscip Cardiovasc Thorac Surg Valvular Heart Disease OBJECTIVES: Surgical supra-annular aortic valvar tissue prostheses are labelled in an inconsistent and confusing manner. If the replaced valve is too small for a given patient, the risk of patient-prosthesis mismatch is increased, which is associated with the risk of morbidity and mortality. The labelled diameter (LD) of these valves should coincide with the inflow orifice diameter (IOD). Therefore, our goal was to measure all relevant IODs. METHODS: Valvar design was assessed in terms of the intended position of the valve in relation to the patient’s annulus. The IODs of all available supra-annular aortic valvar prostheses were measured using a conical gauge. The IODs were compared to the LDs. We searched for instructions for use, websites, packing boxes and regulatory institutions involved in the process. RESULTS: Eight valve models from 4 manufacturers were included. None of these valves were clearly labelled as supra-annular on the packing box, although for 3, the supra-annular label could be found in the written specifications. All valves had an IOD smaller than their LD, with a median difference of 15% (range: 4%–25%). The departure from LD differed per valve model and valve size. CONCLUSIONS: Valve packages should be labelled accurately and clearly so that surgeons can make a well-informed choice. Currently essential information is missing because the intended position in relation to the annulus is not consistently marked on the packing boxes, and valve sizes are labelled incorrectly. We propose a change for the better: relabel all valves according to their true IOD in a structured manner. Oxford University Press 2023-05-15 /pmc/articles/PMC10301699/ /pubmed/37184926 http://dx.doi.org/10.1093/icvts/ivad076 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Valvular Heart Disease van Boxtel, Astrid Gerritje Maria Mariani, Massimo Alessandro Ebels, Tjark All surgical supra-annular aortic valvar tissue prostheses are labelled too large |
title | All surgical supra-annular aortic valvar tissue prostheses are labelled too large |
title_full | All surgical supra-annular aortic valvar tissue prostheses are labelled too large |
title_fullStr | All surgical supra-annular aortic valvar tissue prostheses are labelled too large |
title_full_unstemmed | All surgical supra-annular aortic valvar tissue prostheses are labelled too large |
title_short | All surgical supra-annular aortic valvar tissue prostheses are labelled too large |
title_sort | all surgical supra-annular aortic valvar tissue prostheses are labelled too large |
topic | Valvular Heart Disease |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301699/ https://www.ncbi.nlm.nih.gov/pubmed/37184926 http://dx.doi.org/10.1093/icvts/ivad076 |
work_keys_str_mv | AT vanboxtelastridgerritjemaria allsurgicalsupraannularaorticvalvartissueprosthesesarelabelledtoolarge AT marianimassimoalessandro allsurgicalsupraannularaorticvalvartissueprosthesesarelabelledtoolarge AT ebelstjark allsurgicalsupraannularaorticvalvartissueprosthesesarelabelledtoolarge |