Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range

Six different composites of epoxy resin and Carbopol 974p polymer were prepared based on Carbopol 974p polymer concentrations of 0%, 5%, 10%, 15%, 20%, and 25%. The linear and mass attenuation coefficients, Half Value Layer (HVL), and mean free path (MFP) of these composites were determined using si...

Descripción completa

Detalles Bibliográficos
Autores principales: Marashdeh, Mohammad, Abdulkarim, Muthanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301711/
https://www.ncbi.nlm.nih.gov/pubmed/37376291
http://dx.doi.org/10.3390/polym15122645
_version_ 1785064877176389632
author Marashdeh, Mohammad
Abdulkarim, Muthanna
author_facet Marashdeh, Mohammad
Abdulkarim, Muthanna
author_sort Marashdeh, Mohammad
collection PubMed
description Six different composites of epoxy resin and Carbopol 974p polymer were prepared based on Carbopol 974p polymer concentrations of 0%, 5%, 10%, 15%, 20%, and 25%. The linear and mass attenuation coefficients, Half Value Layer (HVL), and mean free path (MFP) of these composites were determined using single-beam photon transmission in the energy range between 16.65 keV and 25.21 keV. This was carried out by determining the attenuation of k(a1) X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver, and tin targets. The results were compared with theoretical values of three types of breast material (Breast 1, Breast 2, Breast 3) and Perspex, which was calculated using a XCOM computer program. The results show that there were no significant differences in the attenuation coefficient values after the consequent Carbopol additions. Moreover, it was found that the mass attenuation coefficients of all tested composites were close to those of Perspex and the values for Breast 3. The HVL and MFP results showed that the E25 sample is closer to the results of the Perspex material with differences of (0.53–1.15%) and (0.51–1.20%), respectively. In addition, the densities of the fabricated samples were in the range of 1.102–1.170 g/cm(3), which is in the range of human breast density. A computed tomography (CT) scanner was used to investigate the CT number values for the fabricated samples. The CT numbers of all samples were in the range of human breast tissue (24.53–40.28 HU). Based on these findings, the fabricated epoxy–Carbopol polymer is a good candidate for use as a breast phantom material.
format Online
Article
Text
id pubmed-10301711
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103017112023-06-29 Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range Marashdeh, Mohammad Abdulkarim, Muthanna Polymers (Basel) Article Six different composites of epoxy resin and Carbopol 974p polymer were prepared based on Carbopol 974p polymer concentrations of 0%, 5%, 10%, 15%, 20%, and 25%. The linear and mass attenuation coefficients, Half Value Layer (HVL), and mean free path (MFP) of these composites were determined using single-beam photon transmission in the energy range between 16.65 keV and 25.21 keV. This was carried out by determining the attenuation of k(a1) X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver, and tin targets. The results were compared with theoretical values of three types of breast material (Breast 1, Breast 2, Breast 3) and Perspex, which was calculated using a XCOM computer program. The results show that there were no significant differences in the attenuation coefficient values after the consequent Carbopol additions. Moreover, it was found that the mass attenuation coefficients of all tested composites were close to those of Perspex and the values for Breast 3. The HVL and MFP results showed that the E25 sample is closer to the results of the Perspex material with differences of (0.53–1.15%) and (0.51–1.20%), respectively. In addition, the densities of the fabricated samples were in the range of 1.102–1.170 g/cm(3), which is in the range of human breast density. A computed tomography (CT) scanner was used to investigate the CT number values for the fabricated samples. The CT numbers of all samples were in the range of human breast tissue (24.53–40.28 HU). Based on these findings, the fabricated epoxy–Carbopol polymer is a good candidate for use as a breast phantom material. MDPI 2023-06-11 /pmc/articles/PMC10301711/ /pubmed/37376291 http://dx.doi.org/10.3390/polym15122645 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Marashdeh, Mohammad
Abdulkarim, Muthanna
Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range
title Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range
title_full Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range
title_fullStr Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range
title_full_unstemmed Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range
title_short Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range
title_sort determination of the attenuation coefficients of epoxy resin with carbopol polymer as a breast phantom material at low photon energy range
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301711/
https://www.ncbi.nlm.nih.gov/pubmed/37376291
http://dx.doi.org/10.3390/polym15122645
work_keys_str_mv AT marashdehmohammad determinationoftheattenuationcoefficientsofepoxyresinwithcarbopolpolymerasabreastphantommaterialatlowphotonenergyrange
AT abdulkarimmuthanna determinationoftheattenuationcoefficientsofepoxyresinwithcarbopolpolymerasabreastphantommaterialatlowphotonenergyrange