Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response

The integration of liquid exchange and microfluidic chips plays a critical role in the biomedical and biophysical fields as it enables the control of the extracellular environment and allows for the simultaneous stimulation and detection of single cells. In this study, we present a novel approach fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Du, Xu, Kaneko, Shingo, Maruyama, Hisataka, Sugiura, Hirotaka, Tsujii, Masaru, Uozumi, Nobuyuki, Arai, Fumihito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301842/
https://www.ncbi.nlm.nih.gov/pubmed/37374795
http://dx.doi.org/10.3390/mi14061210
_version_ 1785064908094701568
author Du, Xu
Kaneko, Shingo
Maruyama, Hisataka
Sugiura, Hirotaka
Tsujii, Masaru
Uozumi, Nobuyuki
Arai, Fumihito
author_facet Du, Xu
Kaneko, Shingo
Maruyama, Hisataka
Sugiura, Hirotaka
Tsujii, Masaru
Uozumi, Nobuyuki
Arai, Fumihito
author_sort Du, Xu
collection PubMed
description The integration of liquid exchange and microfluidic chips plays a critical role in the biomedical and biophysical fields as it enables the control of the extracellular environment and allows for the simultaneous stimulation and detection of single cells. In this study, we present a novel approach for measuring the transient response of single cells using a system integrated with a microfluidic chip and a probe with a dual pump. The system was composed of a probe with a dual pump system, a microfluidic chip, optical tweezers, an external manipulator, an external piezo actuator, etc. Particularly, we incorporated the probe with the dual pump to allow for high-speed liquid change, and the localized flow control enabled a low disturbance contact force detection of single cells on the chip. Using this system, we measured the transient response of the cell swelling against the osmotic shock with a very fine time resolution. To demonstrate the concept, we first designed the double-barreled pipette, which was assembled with two piezo pumps to achieve a probe with the dual pump system, allowing for simultaneous liquid injection and suction. The microfluidic chip with on-chip probes was fabricated, and the integrated force sensor was calibrated. Second, we characterized the performance of the probe with the dual pump system, and the effect of the analysis position and area of the liquid exchange time was investigated. In addition, we optimized the applied injection voltage to achieve a complete concentration change, and the average liquid exchange time was achieved at approximately 3.33 ms. Finally, we demonstrated that the force sensor was only subjected to minor disturbances during the liquid exchange. This system was utilized to measure the deformation and the reactive force of Synechocystis sp. strain PCC 6803 in osmotic shock, with an average response time of approximately 16.33 ms. This system reveals the transient response of compressed single cells under millisecond osmotic shock which has the potential to characterize the accurate physiological function of ion channels.
format Online
Article
Text
id pubmed-10301842
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103018422023-06-29 Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response Du, Xu Kaneko, Shingo Maruyama, Hisataka Sugiura, Hirotaka Tsujii, Masaru Uozumi, Nobuyuki Arai, Fumihito Micromachines (Basel) Article The integration of liquid exchange and microfluidic chips plays a critical role in the biomedical and biophysical fields as it enables the control of the extracellular environment and allows for the simultaneous stimulation and detection of single cells. In this study, we present a novel approach for measuring the transient response of single cells using a system integrated with a microfluidic chip and a probe with a dual pump. The system was composed of a probe with a dual pump system, a microfluidic chip, optical tweezers, an external manipulator, an external piezo actuator, etc. Particularly, we incorporated the probe with the dual pump to allow for high-speed liquid change, and the localized flow control enabled a low disturbance contact force detection of single cells on the chip. Using this system, we measured the transient response of the cell swelling against the osmotic shock with a very fine time resolution. To demonstrate the concept, we first designed the double-barreled pipette, which was assembled with two piezo pumps to achieve a probe with the dual pump system, allowing for simultaneous liquid injection and suction. The microfluidic chip with on-chip probes was fabricated, and the integrated force sensor was calibrated. Second, we characterized the performance of the probe with the dual pump system, and the effect of the analysis position and area of the liquid exchange time was investigated. In addition, we optimized the applied injection voltage to achieve a complete concentration change, and the average liquid exchange time was achieved at approximately 3.33 ms. Finally, we demonstrated that the force sensor was only subjected to minor disturbances during the liquid exchange. This system was utilized to measure the deformation and the reactive force of Synechocystis sp. strain PCC 6803 in osmotic shock, with an average response time of approximately 16.33 ms. This system reveals the transient response of compressed single cells under millisecond osmotic shock which has the potential to characterize the accurate physiological function of ion channels. MDPI 2023-06-07 /pmc/articles/PMC10301842/ /pubmed/37374795 http://dx.doi.org/10.3390/mi14061210 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Du, Xu
Kaneko, Shingo
Maruyama, Hisataka
Sugiura, Hirotaka
Tsujii, Masaru
Uozumi, Nobuyuki
Arai, Fumihito
Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response
title Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response
title_full Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response
title_fullStr Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response
title_full_unstemmed Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response
title_short Integration of Microfluidic Chip and Probe with a Dual Pump System for Measurement of Single Cells Transient Response
title_sort integration of microfluidic chip and probe with a dual pump system for measurement of single cells transient response
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10301842/
https://www.ncbi.nlm.nih.gov/pubmed/37374795
http://dx.doi.org/10.3390/mi14061210
work_keys_str_mv AT duxu integrationofmicrofluidicchipandprobewithadualpumpsystemformeasurementofsinglecellstransientresponse
AT kanekoshingo integrationofmicrofluidicchipandprobewithadualpumpsystemformeasurementofsinglecellstransientresponse
AT maruyamahisataka integrationofmicrofluidicchipandprobewithadualpumpsystemformeasurementofsinglecellstransientresponse
AT sugiurahirotaka integrationofmicrofluidicchipandprobewithadualpumpsystemformeasurementofsinglecellstransientresponse
AT tsujiimasaru integrationofmicrofluidicchipandprobewithadualpumpsystemformeasurementofsinglecellstransientresponse
AT uozuminobuyuki integrationofmicrofluidicchipandprobewithadualpumpsystemformeasurementofsinglecellstransientresponse
AT araifumihito integrationofmicrofluidicchipandprobewithadualpumpsystemformeasurementofsinglecellstransientresponse