Cargando…
Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
Background and Objectives: An acetabular reinforcement ring (ARR) with a structural allograft is conventionally used to treat large acetabular bone defects or discontinuity during revision hip arthroplasty. However, ARR is prone to failure due to bone resorption and lack of incorporation. Here, we i...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10302063/ https://www.ncbi.nlm.nih.gov/pubmed/37374240 http://dx.doi.org/10.3390/medicina59061036 |
_version_ | 1785064960738459648 |
---|---|
author | Kim, Han Soul Kim, Ji Wan Chang, Jae Suk Kim, Chul-Ho |
author_facet | Kim, Han Soul Kim, Ji Wan Chang, Jae Suk Kim, Chul-Ho |
author_sort | Kim, Han Soul |
collection | PubMed |
description | Background and Objectives: An acetabular reinforcement ring (ARR) with a structural allograft is conventionally used to treat large acetabular bone defects or discontinuity during revision hip arthroplasty. However, ARR is prone to failure due to bone resorption and lack of incorporation. Here, we investigated the surgical outcomes of the patients who underwent revision total hip arthroplasty (THA) using ARR combined with a metal augment (MA). Materials and Methods: We retrospectively reviewed data from 10 consecutive patients who had a minimum 8-year follow-up after revision hip arthroplasty using ARR with MA in Paprosky type III acetabular defect. We collected patient demographics, surgical details, clinical scores (including Harris Hip Score (HHS)), postoperative complications, and 8-year survival rates. Results: Six male and four female patients were included. The mean age was 64.3 years, and the mean follow-up duration was 104.3 months (96.0–112.0 months). Trauma-related diagnosis was the most common reason for index surgery. Three patients underwent all component revision, and seven underwent cup revision. Six were confirmed as Paprosky type IIIA and four as type IIIB. The mean HHS at the final follow-up was 81.5 (72–91). One patient was diagnosed with prosthetic joint infection at the 3-month follow-up; therefore, the minimum 8-year survival rate with our technique was 90.0% (95% confidence interval, 90.3–118.5%). Conclusions: The satisfactory mid- to long-term results of revision THA suggest that ARR combined with tantalum MA is a viable revision option for treating severe acetabular defects with pelvic discontinuity. |
format | Online Article Text |
id | pubmed-10302063 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103020632023-06-29 Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study Kim, Han Soul Kim, Ji Wan Chang, Jae Suk Kim, Chul-Ho Medicina (Kaunas) Article Background and Objectives: An acetabular reinforcement ring (ARR) with a structural allograft is conventionally used to treat large acetabular bone defects or discontinuity during revision hip arthroplasty. However, ARR is prone to failure due to bone resorption and lack of incorporation. Here, we investigated the surgical outcomes of the patients who underwent revision total hip arthroplasty (THA) using ARR combined with a metal augment (MA). Materials and Methods: We retrospectively reviewed data from 10 consecutive patients who had a minimum 8-year follow-up after revision hip arthroplasty using ARR with MA in Paprosky type III acetabular defect. We collected patient demographics, surgical details, clinical scores (including Harris Hip Score (HHS)), postoperative complications, and 8-year survival rates. Results: Six male and four female patients were included. The mean age was 64.3 years, and the mean follow-up duration was 104.3 months (96.0–112.0 months). Trauma-related diagnosis was the most common reason for index surgery. Three patients underwent all component revision, and seven underwent cup revision. Six were confirmed as Paprosky type IIIA and four as type IIIB. The mean HHS at the final follow-up was 81.5 (72–91). One patient was diagnosed with prosthetic joint infection at the 3-month follow-up; therefore, the minimum 8-year survival rate with our technique was 90.0% (95% confidence interval, 90.3–118.5%). Conclusions: The satisfactory mid- to long-term results of revision THA suggest that ARR combined with tantalum MA is a viable revision option for treating severe acetabular defects with pelvic discontinuity. MDPI 2023-05-27 /pmc/articles/PMC10302063/ /pubmed/37374240 http://dx.doi.org/10.3390/medicina59061036 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kim, Han Soul Kim, Ji Wan Chang, Jae Suk Kim, Chul-Ho Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study |
title | Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study |
title_full | Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study |
title_fullStr | Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study |
title_full_unstemmed | Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study |
title_short | Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study |
title_sort | revision total hip arthroplasty utilizing an acetabular reinforcement ring with a metal augment: a minimum eight-year follow-up study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10302063/ https://www.ncbi.nlm.nih.gov/pubmed/37374240 http://dx.doi.org/10.3390/medicina59061036 |
work_keys_str_mv | AT kimhansoul revisiontotalhiparthroplastyutilizinganacetabularreinforcementringwithametalaugmentaminimumeightyearfollowupstudy AT kimjiwan revisiontotalhiparthroplastyutilizinganacetabularreinforcementringwithametalaugmentaminimumeightyearfollowupstudy AT changjaesuk revisiontotalhiparthroplastyutilizinganacetabularreinforcementringwithametalaugmentaminimumeightyearfollowupstudy AT kimchulho revisiontotalhiparthroplastyutilizinganacetabularreinforcementringwithametalaugmentaminimumeightyearfollowupstudy |