Cargando…

Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study

Background and Objectives: An acetabular reinforcement ring (ARR) with a structural allograft is conventionally used to treat large acetabular bone defects or discontinuity during revision hip arthroplasty. However, ARR is prone to failure due to bone resorption and lack of incorporation. Here, we i...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Han Soul, Kim, Ji Wan, Chang, Jae Suk, Kim, Chul-Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10302063/
https://www.ncbi.nlm.nih.gov/pubmed/37374240
http://dx.doi.org/10.3390/medicina59061036
_version_ 1785064960738459648
author Kim, Han Soul
Kim, Ji Wan
Chang, Jae Suk
Kim, Chul-Ho
author_facet Kim, Han Soul
Kim, Ji Wan
Chang, Jae Suk
Kim, Chul-Ho
author_sort Kim, Han Soul
collection PubMed
description Background and Objectives: An acetabular reinforcement ring (ARR) with a structural allograft is conventionally used to treat large acetabular bone defects or discontinuity during revision hip arthroplasty. However, ARR is prone to failure due to bone resorption and lack of incorporation. Here, we investigated the surgical outcomes of the patients who underwent revision total hip arthroplasty (THA) using ARR combined with a metal augment (MA). Materials and Methods: We retrospectively reviewed data from 10 consecutive patients who had a minimum 8-year follow-up after revision hip arthroplasty using ARR with MA in Paprosky type III acetabular defect. We collected patient demographics, surgical details, clinical scores (including Harris Hip Score (HHS)), postoperative complications, and 8-year survival rates. Results: Six male and four female patients were included. The mean age was 64.3 years, and the mean follow-up duration was 104.3 months (96.0–112.0 months). Trauma-related diagnosis was the most common reason for index surgery. Three patients underwent all component revision, and seven underwent cup revision. Six were confirmed as Paprosky type IIIA and four as type IIIB. The mean HHS at the final follow-up was 81.5 (72–91). One patient was diagnosed with prosthetic joint infection at the 3-month follow-up; therefore, the minimum 8-year survival rate with our technique was 90.0% (95% confidence interval, 90.3–118.5%). Conclusions: The satisfactory mid- to long-term results of revision THA suggest that ARR combined with tantalum MA is a viable revision option for treating severe acetabular defects with pelvic discontinuity.
format Online
Article
Text
id pubmed-10302063
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103020632023-06-29 Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study Kim, Han Soul Kim, Ji Wan Chang, Jae Suk Kim, Chul-Ho Medicina (Kaunas) Article Background and Objectives: An acetabular reinforcement ring (ARR) with a structural allograft is conventionally used to treat large acetabular bone defects or discontinuity during revision hip arthroplasty. However, ARR is prone to failure due to bone resorption and lack of incorporation. Here, we investigated the surgical outcomes of the patients who underwent revision total hip arthroplasty (THA) using ARR combined with a metal augment (MA). Materials and Methods: We retrospectively reviewed data from 10 consecutive patients who had a minimum 8-year follow-up after revision hip arthroplasty using ARR with MA in Paprosky type III acetabular defect. We collected patient demographics, surgical details, clinical scores (including Harris Hip Score (HHS)), postoperative complications, and 8-year survival rates. Results: Six male and four female patients were included. The mean age was 64.3 years, and the mean follow-up duration was 104.3 months (96.0–112.0 months). Trauma-related diagnosis was the most common reason for index surgery. Three patients underwent all component revision, and seven underwent cup revision. Six were confirmed as Paprosky type IIIA and four as type IIIB. The mean HHS at the final follow-up was 81.5 (72–91). One patient was diagnosed with prosthetic joint infection at the 3-month follow-up; therefore, the minimum 8-year survival rate with our technique was 90.0% (95% confidence interval, 90.3–118.5%). Conclusions: The satisfactory mid- to long-term results of revision THA suggest that ARR combined with tantalum MA is a viable revision option for treating severe acetabular defects with pelvic discontinuity. MDPI 2023-05-27 /pmc/articles/PMC10302063/ /pubmed/37374240 http://dx.doi.org/10.3390/medicina59061036 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Han Soul
Kim, Ji Wan
Chang, Jae Suk
Kim, Chul-Ho
Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
title Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
title_full Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
title_fullStr Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
title_full_unstemmed Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
title_short Revision Total Hip Arthroplasty Utilizing an Acetabular Reinforcement Ring with a Metal Augment: A Minimum Eight-Year Follow-Up Study
title_sort revision total hip arthroplasty utilizing an acetabular reinforcement ring with a metal augment: a minimum eight-year follow-up study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10302063/
https://www.ncbi.nlm.nih.gov/pubmed/37374240
http://dx.doi.org/10.3390/medicina59061036
work_keys_str_mv AT kimhansoul revisiontotalhiparthroplastyutilizinganacetabularreinforcementringwithametalaugmentaminimumeightyearfollowupstudy
AT kimjiwan revisiontotalhiparthroplastyutilizinganacetabularreinforcementringwithametalaugmentaminimumeightyearfollowupstudy
AT changjaesuk revisiontotalhiparthroplastyutilizinganacetabularreinforcementringwithametalaugmentaminimumeightyearfollowupstudy
AT kimchulho revisiontotalhiparthroplastyutilizinganacetabularreinforcementringwithametalaugmentaminimumeightyearfollowupstudy