Cargando…
Femoral Tunnel Geometry and Graft Inclination Angles in Anterior Cruciate Ligament Reconstruction Using a Flexible Reamer System
Background and Objectives: The aim of this study is to investigate the femoral tunnel geometry (femoral tunsnel location, femoral graft bending angle, and femoral tunnel length) on three-dimensional (3D) computed tomography (CT) and graft inclination on magnetic resonance imaging (MRI) after anatomi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10302174/ https://www.ncbi.nlm.nih.gov/pubmed/37374234 http://dx.doi.org/10.3390/medicina59061031 |
Sumario: | Background and Objectives: The aim of this study is to investigate the femoral tunnel geometry (femoral tunsnel location, femoral graft bending angle, and femoral tunnel length) on three-dimensional (3D) computed tomography (CT) and graft inclination on magnetic resonance imaging (MRI) after anatomic anterior cruciate ligament (ACL) reconstruction using a flexible reamer system. Materials and Methods: A total of 60 patients who underwent anatomical ACL reconstruction (ACLR) using a flexible reamer system were retrospectively reviewed. One day after the ACLR procedure was performed, all patients underwent three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI). The femoral tunnel location, femoral graft bending angle, femoral tunnel length, and graft inclination were assessed. Results: In the 3D-CTs, the femoral tunnel was located at 29.7 ± 4.4% in the posterior to anterior (deep to shallow) direction and at 24.1 ± 5.9% in the proximal to distal (high to low) direction. The mean femoral graft bending angle was 113.9 ± 5.7°, and the mean femoral tunnel length was 35.2 ± 3.1 mm. Posterior wall breakage was observed in five patients (8.3%). In the MRIs, the mean coronal graft inclination was 69.2 ± 4.7°, and the mean sagittal graft inclination was 52.4 ± 4.6°. The results of this study demonstrated that a comparable femoral graft bending angle and longer femoral tunnel length were observed compared with the reported outcomes from previous studies that used the rigid reamer system. Conclusions: ACLR using a flexible reamer system allowed for an anatomic femoral tunnel location and a comparable graft inclination to that of the native ACL. In addition, it achieved a tolerable femoral graft bending angle and femoral tunnel length. |
---|