Cargando…

Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5′-Carboxymeloxicam in Oral Fluid Samples

A sensitive, selective and particularly fast method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of meloxicam and its main metabolite, 5′-carboxymeloxicam, in oral fluid samples. Meloxicam and its major metabolite were separated using...

Descripción completa

Detalles Bibliográficos
Autores principales: Oliveira, Gabriela Moraes, Dionísio, Thiago José, Siqueira-Sandrin, Viviane Silva, Ferrari, Leticia Alves de Lima, Colombini-Ishikiriama, Bella Luna, Faria, Flávio Augusto Cardoso, Santos, Carlos Ferreira, Calvo, Adriana Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10302853/
https://www.ncbi.nlm.nih.gov/pubmed/37367912
http://dx.doi.org/10.3390/metabo13060755
_version_ 1785065141008596992
author Oliveira, Gabriela Moraes
Dionísio, Thiago José
Siqueira-Sandrin, Viviane Silva
Ferrari, Leticia Alves de Lima
Colombini-Ishikiriama, Bella Luna
Faria, Flávio Augusto Cardoso
Santos, Carlos Ferreira
Calvo, Adriana Maria
author_facet Oliveira, Gabriela Moraes
Dionísio, Thiago José
Siqueira-Sandrin, Viviane Silva
Ferrari, Leticia Alves de Lima
Colombini-Ishikiriama, Bella Luna
Faria, Flávio Augusto Cardoso
Santos, Carlos Ferreira
Calvo, Adriana Maria
author_sort Oliveira, Gabriela Moraes
collection PubMed
description A sensitive, selective and particularly fast method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of meloxicam and its main metabolite, 5′-carboxymeloxicam, in oral fluid samples. Meloxicam and its major metabolite were separated using a Shim-Pack XR-ODS 75 L × 2.0 column and C18 pre-column at 40 °C using a mixture of methanol and 10 mM ammonium acetate (80:20, v/v) with an injection flow rate of 0.3 mL/min. The total time of the analytical run was 5 min. Sixteen volunteers had oral fluid samples collected sequentially before and after taking a meloxicam tablet (15 mg) for up to 96 h. With the concentrations obtained, the pharmacokinetic parameters were determined using the Phoenix WinNonlin software. The parameters evaluated for meloxicam and 5′-carboxymeloxicam in the oral fluid samples showed linearity, accuracy, precision, medium-quality control (MQC-78.12 ng/mL), high-quality control (HQC-156.25 ng/mL), lower limits of quantification (LLOQ-0.6103 ng/mL), low-quality control (LQC-2.44 ng/mL), stability and dilution. Prostaglandin E(2) (PGE(2)) was also detected and quantified in the oral fluid samples, demonstrating the possibility of a pharmacokinetic/pharmacodynamic (PK/PD) study with this methodology. All the parameters evaluated in the validation of the methodology in the oral fluid samples proved to be stable and within the possible variations in each of the described parameters. Through the data presented, the possibility of a PK/PD study was demonstrated, detecting and quantifying meloxicam, its main metabolite and PGE(2) in oral fluid samples using LC-MS/MS.
format Online
Article
Text
id pubmed-10302853
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103028532023-06-29 Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5′-Carboxymeloxicam in Oral Fluid Samples Oliveira, Gabriela Moraes Dionísio, Thiago José Siqueira-Sandrin, Viviane Silva Ferrari, Leticia Alves de Lima Colombini-Ishikiriama, Bella Luna Faria, Flávio Augusto Cardoso Santos, Carlos Ferreira Calvo, Adriana Maria Metabolites Article A sensitive, selective and particularly fast method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of meloxicam and its main metabolite, 5′-carboxymeloxicam, in oral fluid samples. Meloxicam and its major metabolite were separated using a Shim-Pack XR-ODS 75 L × 2.0 column and C18 pre-column at 40 °C using a mixture of methanol and 10 mM ammonium acetate (80:20, v/v) with an injection flow rate of 0.3 mL/min. The total time of the analytical run was 5 min. Sixteen volunteers had oral fluid samples collected sequentially before and after taking a meloxicam tablet (15 mg) for up to 96 h. With the concentrations obtained, the pharmacokinetic parameters were determined using the Phoenix WinNonlin software. The parameters evaluated for meloxicam and 5′-carboxymeloxicam in the oral fluid samples showed linearity, accuracy, precision, medium-quality control (MQC-78.12 ng/mL), high-quality control (HQC-156.25 ng/mL), lower limits of quantification (LLOQ-0.6103 ng/mL), low-quality control (LQC-2.44 ng/mL), stability and dilution. Prostaglandin E(2) (PGE(2)) was also detected and quantified in the oral fluid samples, demonstrating the possibility of a pharmacokinetic/pharmacodynamic (PK/PD) study with this methodology. All the parameters evaluated in the validation of the methodology in the oral fluid samples proved to be stable and within the possible variations in each of the described parameters. Through the data presented, the possibility of a PK/PD study was demonstrated, detecting and quantifying meloxicam, its main metabolite and PGE(2) in oral fluid samples using LC-MS/MS. MDPI 2023-06-15 /pmc/articles/PMC10302853/ /pubmed/37367912 http://dx.doi.org/10.3390/metabo13060755 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oliveira, Gabriela Moraes
Dionísio, Thiago José
Siqueira-Sandrin, Viviane Silva
Ferrari, Leticia Alves de Lima
Colombini-Ishikiriama, Bella Luna
Faria, Flávio Augusto Cardoso
Santos, Carlos Ferreira
Calvo, Adriana Maria
Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5′-Carboxymeloxicam in Oral Fluid Samples
title Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5′-Carboxymeloxicam in Oral Fluid Samples
title_full Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5′-Carboxymeloxicam in Oral Fluid Samples
title_fullStr Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5′-Carboxymeloxicam in Oral Fluid Samples
title_full_unstemmed Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5′-Carboxymeloxicam in Oral Fluid Samples
title_short Liquid Chromatography-Tandem Mass Spectrometry Method for Detection and Quantification of Meloxicam and 5′-Carboxymeloxicam in Oral Fluid Samples
title_sort liquid chromatography-tandem mass spectrometry method for detection and quantification of meloxicam and 5′-carboxymeloxicam in oral fluid samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10302853/
https://www.ncbi.nlm.nih.gov/pubmed/37367912
http://dx.doi.org/10.3390/metabo13060755
work_keys_str_mv AT oliveiragabrielamoraes liquidchromatographytandemmassspectrometrymethodfordetectionandquantificationofmeloxicamand5carboxymeloxicaminoralfluidsamples
AT dionisiothiagojose liquidchromatographytandemmassspectrometrymethodfordetectionandquantificationofmeloxicamand5carboxymeloxicaminoralfluidsamples
AT siqueirasandrinvivianesilva liquidchromatographytandemmassspectrometrymethodfordetectionandquantificationofmeloxicamand5carboxymeloxicaminoralfluidsamples
AT ferrarileticiaalvesdelima liquidchromatographytandemmassspectrometrymethodfordetectionandquantificationofmeloxicamand5carboxymeloxicaminoralfluidsamples
AT colombiniishikiriamabellaluna liquidchromatographytandemmassspectrometrymethodfordetectionandquantificationofmeloxicamand5carboxymeloxicaminoralfluidsamples
AT fariaflavioaugustocardoso liquidchromatographytandemmassspectrometrymethodfordetectionandquantificationofmeloxicamand5carboxymeloxicaminoralfluidsamples
AT santoscarlosferreira liquidchromatographytandemmassspectrometrymethodfordetectionandquantificationofmeloxicamand5carboxymeloxicaminoralfluidsamples
AT calvoadrianamaria liquidchromatographytandemmassspectrometrymethodfordetectionandquantificationofmeloxicamand5carboxymeloxicaminoralfluidsamples