Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis

This work presents an innovative application of Frequency Response Analysis (FRA) in order to detect early degradation of Metal Oxide Surge Arresters (MOSAs). This technique has been widely used in power transformers, but has never been applied to MOSAs. It consists in comparisons of spectra, measur...

Descripción completa

Detalles Bibliográficos
Autores principales: Zacarias, Tiago Goncalves, Martins, Rafael, Xavier, Carlos Eduardo, Castioni, Julio Cezar Oliveira, Sant’Ana, Wilson Cesar, Lambert-Torres, Germano, Gama, Bruno Reno, Areias, Isac Antonio dos Santos, Bonaldi, Erik Leandro, Assuncao, Frederico De Oliveira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303026/
https://www.ncbi.nlm.nih.gov/pubmed/37420799
http://dx.doi.org/10.3390/s23125633
_version_ 1785065181667131392
author Zacarias, Tiago Goncalves
Martins, Rafael
Xavier, Carlos Eduardo
Castioni, Julio Cezar Oliveira
Sant’Ana, Wilson Cesar
Lambert-Torres, Germano
Gama, Bruno Reno
Areias, Isac Antonio dos Santos
Bonaldi, Erik Leandro
Assuncao, Frederico De Oliveira
author_facet Zacarias, Tiago Goncalves
Martins, Rafael
Xavier, Carlos Eduardo
Castioni, Julio Cezar Oliveira
Sant’Ana, Wilson Cesar
Lambert-Torres, Germano
Gama, Bruno Reno
Areias, Isac Antonio dos Santos
Bonaldi, Erik Leandro
Assuncao, Frederico De Oliveira
author_sort Zacarias, Tiago Goncalves
collection PubMed
description This work presents an innovative application of Frequency Response Analysis (FRA) in order to detect early degradation of Metal Oxide Surge Arresters (MOSAs). This technique has been widely used in power transformers, but has never been applied to MOSAs. It consists in comparisons of spectra, measured at different instants of the lifetime of the arrester. Differences between these spectra are an indicator that some electrical properties of the arrester have changed. An incremental deterioration test has been performed on arrester samples (with controlled circulation of leakage current, which increases the energy dissipation over the device), and the FRA spectra correctly identified the progression of damage. Although preliminary, the FRA results seemed promising, and it is expected that this technology could be used as another diagnostic tool for arresters.
format Online
Article
Text
id pubmed-10303026
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103030262023-06-29 Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis Zacarias, Tiago Goncalves Martins, Rafael Xavier, Carlos Eduardo Castioni, Julio Cezar Oliveira Sant’Ana, Wilson Cesar Lambert-Torres, Germano Gama, Bruno Reno Areias, Isac Antonio dos Santos Bonaldi, Erik Leandro Assuncao, Frederico De Oliveira Sensors (Basel) Article This work presents an innovative application of Frequency Response Analysis (FRA) in order to detect early degradation of Metal Oxide Surge Arresters (MOSAs). This technique has been widely used in power transformers, but has never been applied to MOSAs. It consists in comparisons of spectra, measured at different instants of the lifetime of the arrester. Differences between these spectra are an indicator that some electrical properties of the arrester have changed. An incremental deterioration test has been performed on arrester samples (with controlled circulation of leakage current, which increases the energy dissipation over the device), and the FRA spectra correctly identified the progression of damage. Although preliminary, the FRA results seemed promising, and it is expected that this technology could be used as another diagnostic tool for arresters. MDPI 2023-06-16 /pmc/articles/PMC10303026/ /pubmed/37420799 http://dx.doi.org/10.3390/s23125633 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zacarias, Tiago Goncalves
Martins, Rafael
Xavier, Carlos Eduardo
Castioni, Julio Cezar Oliveira
Sant’Ana, Wilson Cesar
Lambert-Torres, Germano
Gama, Bruno Reno
Areias, Isac Antonio dos Santos
Bonaldi, Erik Leandro
Assuncao, Frederico De Oliveira
Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis
title Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis
title_full Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis
title_fullStr Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis
title_full_unstemmed Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis
title_short Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis
title_sort detection of failures in metal oxide surge arresters using frequency response analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303026/
https://www.ncbi.nlm.nih.gov/pubmed/37420799
http://dx.doi.org/10.3390/s23125633
work_keys_str_mv AT zacariastiagogoncalves detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT martinsrafael detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT xaviercarloseduardo detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT castionijuliocezaroliveira detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT santanawilsoncesar detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT lamberttorresgermano detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT gamabrunoreno detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT areiasisacantoniodossantos detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT bonaldierikleandro detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis
AT assuncaofredericodeoliveira detectionoffailuresinmetaloxidesurgearrestersusingfrequencyresponseanalysis