Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications
Recent developments in MEMS technologies have made such devices attractive for use in applications that involve precision engineering and scalability. In the biomedical industry, MEMS devices have gained popularity in recent years for use as single-cell manipulation and characterisation tools. A nic...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303803/ https://www.ncbi.nlm.nih.gov/pubmed/37374848 http://dx.doi.org/10.3390/mi14061264 |
_version_ | 1785065361498963968 |
---|---|
author | Sciberras, Thomas Demicoli, Marija Grech, Ivan Mallia, Bertram Mollicone, Pierluigi Sammut, Nicholas |
author_facet | Sciberras, Thomas Demicoli, Marija Grech, Ivan Mallia, Bertram Mollicone, Pierluigi Sammut, Nicholas |
author_sort | Sciberras, Thomas |
collection | PubMed |
description | Recent developments in MEMS technologies have made such devices attractive for use in applications that involve precision engineering and scalability. In the biomedical industry, MEMS devices have gained popularity in recent years for use as single-cell manipulation and characterisation tools. A niche application is the mechanical characterisation of single human red blood cells, which may exhibit certain pathological conditions that impart biomarkers of quantifiable magnitude that are potentially detectable via MEMS devices. Such applications come with stringent thermal and structural specifications wherein the potential device candidates must be able to function with no exceptions. This work presents a state-of-the-art numerical modelling methodology that is capable of accurately predicting MEMS device performance in various media, including aqueous ones. The method is strongly coupled in nature, whereby thermal as well as structural degrees of freedom are transferred to and from finite element and finite volume solvers at every iteration. This method therefore provides MEMS design engineers with a reliable tool that can be used in design and development stages and helps to avoid total reliability on experimental testing. The proposed numerical model is validated via a series of physical experiments. Four MEMS electrothermal actuators with cascaded V-shaped drivers are presented. With the use of the newly proposed numerical model as well as the experimental testing, the MEMS devices’ suitability for biomedical applications is confirmed. |
format | Online Article Text |
id | pubmed-10303803 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103038032023-06-29 Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications Sciberras, Thomas Demicoli, Marija Grech, Ivan Mallia, Bertram Mollicone, Pierluigi Sammut, Nicholas Micromachines (Basel) Article Recent developments in MEMS technologies have made such devices attractive for use in applications that involve precision engineering and scalability. In the biomedical industry, MEMS devices have gained popularity in recent years for use as single-cell manipulation and characterisation tools. A niche application is the mechanical characterisation of single human red blood cells, which may exhibit certain pathological conditions that impart biomarkers of quantifiable magnitude that are potentially detectable via MEMS devices. Such applications come with stringent thermal and structural specifications wherein the potential device candidates must be able to function with no exceptions. This work presents a state-of-the-art numerical modelling methodology that is capable of accurately predicting MEMS device performance in various media, including aqueous ones. The method is strongly coupled in nature, whereby thermal as well as structural degrees of freedom are transferred to and from finite element and finite volume solvers at every iteration. This method therefore provides MEMS design engineers with a reliable tool that can be used in design and development stages and helps to avoid total reliability on experimental testing. The proposed numerical model is validated via a series of physical experiments. Four MEMS electrothermal actuators with cascaded V-shaped drivers are presented. With the use of the newly proposed numerical model as well as the experimental testing, the MEMS devices’ suitability for biomedical applications is confirmed. MDPI 2023-06-17 /pmc/articles/PMC10303803/ /pubmed/37374848 http://dx.doi.org/10.3390/mi14061264 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sciberras, Thomas Demicoli, Marija Grech, Ivan Mallia, Bertram Mollicone, Pierluigi Sammut, Nicholas Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications |
title | Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications |
title_full | Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications |
title_fullStr | Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications |
title_full_unstemmed | Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications |
title_short | Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications |
title_sort | thermo-mechanical fluid–structure interaction numerical modelling and experimental validation of mems electrothermal actuators for aqueous biomedical applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303803/ https://www.ncbi.nlm.nih.gov/pubmed/37374848 http://dx.doi.org/10.3390/mi14061264 |
work_keys_str_mv | AT sciberrasthomas thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications AT demicolimarija thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications AT grechivan thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications AT malliabertram thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications AT molliconepierluigi thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications AT sammutnicholas thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications |