Recent developments in MEMS technologies have made such devices attractive for use in applications that involve precision engineering and scalability. In the biomedical industry, MEMS devices have gained popularity in recent years for use as single-cell manipulation and characterisation tools. A nic...

Descripción completa

Detalles Bibliográficos
Autores principales: Sciberras, Thomas, Demicoli, Marija, Grech, Ivan, Mallia, Bertram, Mollicone, Pierluigi, Sammut, Nicholas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303803/
https://www.ncbi.nlm.nih.gov/pubmed/37374848
http://dx.doi.org/10.3390/mi14061264
_version_ 1785065361498963968
author Sciberras, Thomas
Demicoli, Marija
Grech, Ivan
Mallia, Bertram
Mollicone, Pierluigi
Sammut, Nicholas
author_facet Sciberras, Thomas
Demicoli, Marija
Grech, Ivan
Mallia, Bertram
Mollicone, Pierluigi
Sammut, Nicholas
author_sort Sciberras, Thomas
collection PubMed
description Recent developments in MEMS technologies have made such devices attractive for use in applications that involve precision engineering and scalability. In the biomedical industry, MEMS devices have gained popularity in recent years for use as single-cell manipulation and characterisation tools. A niche application is the mechanical characterisation of single human red blood cells, which may exhibit certain pathological conditions that impart biomarkers of quantifiable magnitude that are potentially detectable via MEMS devices. Such applications come with stringent thermal and structural specifications wherein the potential device candidates must be able to function with no exceptions. This work presents a state-of-the-art numerical modelling methodology that is capable of accurately predicting MEMS device performance in various media, including aqueous ones. The method is strongly coupled in nature, whereby thermal as well as structural degrees of freedom are transferred to and from finite element and finite volume solvers at every iteration. This method therefore provides MEMS design engineers with a reliable tool that can be used in design and development stages and helps to avoid total reliability on experimental testing. The proposed numerical model is validated via a series of physical experiments. Four MEMS electrothermal actuators with cascaded V-shaped drivers are presented. With the use of the newly proposed numerical model as well as the experimental testing, the MEMS devices’ suitability for biomedical applications is confirmed.
format Online
Article
Text
id pubmed-10303803
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103038032023-06-29 Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications Sciberras, Thomas Demicoli, Marija Grech, Ivan Mallia, Bertram Mollicone, Pierluigi Sammut, Nicholas Micromachines (Basel) Article Recent developments in MEMS technologies have made such devices attractive for use in applications that involve precision engineering and scalability. In the biomedical industry, MEMS devices have gained popularity in recent years for use as single-cell manipulation and characterisation tools. A niche application is the mechanical characterisation of single human red blood cells, which may exhibit certain pathological conditions that impart biomarkers of quantifiable magnitude that are potentially detectable via MEMS devices. Such applications come with stringent thermal and structural specifications wherein the potential device candidates must be able to function with no exceptions. This work presents a state-of-the-art numerical modelling methodology that is capable of accurately predicting MEMS device performance in various media, including aqueous ones. The method is strongly coupled in nature, whereby thermal as well as structural degrees of freedom are transferred to and from finite element and finite volume solvers at every iteration. This method therefore provides MEMS design engineers with a reliable tool that can be used in design and development stages and helps to avoid total reliability on experimental testing. The proposed numerical model is validated via a series of physical experiments. Four MEMS electrothermal actuators with cascaded V-shaped drivers are presented. With the use of the newly proposed numerical model as well as the experimental testing, the MEMS devices’ suitability for biomedical applications is confirmed. MDPI 2023-06-17 /pmc/articles/PMC10303803/ /pubmed/37374848 http://dx.doi.org/10.3390/mi14061264 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sciberras, Thomas
Demicoli, Marija
Grech, Ivan
Mallia, Bertram
Mollicone, Pierluigi
Sammut, Nicholas
Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications
title Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications
title_full Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications
title_fullStr Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications
title_full_unstemmed Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications
title_short Thermo-Mechanical Fluid–Structure Interaction Numerical Modelling and Experimental Validation of MEMS Electrothermal Actuators for Aqueous Biomedical Applications
title_sort thermo-mechanical fluid–structure interaction numerical modelling and experimental validation of mems electrothermal actuators for aqueous biomedical applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10303803/
https://www.ncbi.nlm.nih.gov/pubmed/37374848
http://dx.doi.org/10.3390/mi14061264
work_keys_str_mv AT sciberrasthomas thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications
AT demicolimarija thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications
AT grechivan thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications
AT malliabertram thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications
AT molliconepierluigi thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications
AT sammutnicholas thermomechanicalfluidstructureinteractionnumericalmodellingandexperimentalvalidationofmemselectrothermalactuatorsforaqueousbiomedicalapplications