Cargando…
Incidental Axillary Dose of Tomotherapy in Hypofractionated Whole Breast Radiotherapy for Early Breast Cancer: A Dosimetrical Analysis
Background and Objectives: Intensity-modulated radiation therapy (IMRT) is becoming a more common method of performing whole breast irradiation (WBI) for early breast cancer. This study aimed to examine the incidental dose to the axillary region using tomotherapy, a unique form of IMRT. Patients and...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304072/ https://www.ncbi.nlm.nih.gov/pubmed/37374285 http://dx.doi.org/10.3390/medicina59061081 |
_version_ | 1785065421850804224 |
---|---|
author | Yeo, Seung-Gu Lim, Cheol Wan Hur, Sung-Mo Kim, Zisun Cho, Kwang Hwan Kim, Min-Jeong |
author_facet | Yeo, Seung-Gu Lim, Cheol Wan Hur, Sung-Mo Kim, Zisun Cho, Kwang Hwan Kim, Min-Jeong |
author_sort | Yeo, Seung-Gu |
collection | PubMed |
description | Background and Objectives: Intensity-modulated radiation therapy (IMRT) is becoming a more common method of performing whole breast irradiation (WBI) for early breast cancer. This study aimed to examine the incidental dose to the axillary region using tomotherapy, a unique form of IMRT. Patients and Methods: This study included 30 patients with early-stage breast cancer who underwent adjuvant WBI using TomoDirect IMRT. A hypofractionation scheme of 42.4 Gy delivered in 16 fractions was prescribed. The plan comprised of two parallel-opposed beams, along with two additional beams positioned anteriorly at gantry angles of 20° and 40° from the medial beam. The incidental dose received at axillary levels I, II, and III was evaluated using several dose-volume parameters. Results: The study participants had a median age of 51 years, and 60% had left-sided breast cancer. The mean dose of the axilla for levels I, II, and III were 15.5 ± 4.8 Gy, 14.9 ± 4.2 Gy, and 1.5 ± 1.6 Gy, respectively. Adequate coverage of the axilla, defined as V95%[%], was achieved for 4.7 ± 3.9%, 4.8 ± 3.7%, and 0 ± 0% for levels I, II, and III, respectively. The results were compared with those of previously published studies, and the axillary mean dose and V95%[%] of TomoDirect IMRT were low, comparable to other IMRT techniques, and lower than those of traditional tangential therapy. Conclusions: While incidental axillary radiation during WBI has been proposed to assist in regional disease control, the TomoDirect plan was demonstrated to decrease this dose, and a hypofractionation scheme would further lower its biological effectiveness. Future clinical studies should incorporate dosimetrical analysis of incidental axillary dose, in order to facilitate hypofractionated IMRT planning with risk-adjusted axilla coverage in early breast cancer. |
format | Online Article Text |
id | pubmed-10304072 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103040722023-06-29 Incidental Axillary Dose of Tomotherapy in Hypofractionated Whole Breast Radiotherapy for Early Breast Cancer: A Dosimetrical Analysis Yeo, Seung-Gu Lim, Cheol Wan Hur, Sung-Mo Kim, Zisun Cho, Kwang Hwan Kim, Min-Jeong Medicina (Kaunas) Article Background and Objectives: Intensity-modulated radiation therapy (IMRT) is becoming a more common method of performing whole breast irradiation (WBI) for early breast cancer. This study aimed to examine the incidental dose to the axillary region using tomotherapy, a unique form of IMRT. Patients and Methods: This study included 30 patients with early-stage breast cancer who underwent adjuvant WBI using TomoDirect IMRT. A hypofractionation scheme of 42.4 Gy delivered in 16 fractions was prescribed. The plan comprised of two parallel-opposed beams, along with two additional beams positioned anteriorly at gantry angles of 20° and 40° from the medial beam. The incidental dose received at axillary levels I, II, and III was evaluated using several dose-volume parameters. Results: The study participants had a median age of 51 years, and 60% had left-sided breast cancer. The mean dose of the axilla for levels I, II, and III were 15.5 ± 4.8 Gy, 14.9 ± 4.2 Gy, and 1.5 ± 1.6 Gy, respectively. Adequate coverage of the axilla, defined as V95%[%], was achieved for 4.7 ± 3.9%, 4.8 ± 3.7%, and 0 ± 0% for levels I, II, and III, respectively. The results were compared with those of previously published studies, and the axillary mean dose and V95%[%] of TomoDirect IMRT were low, comparable to other IMRT techniques, and lower than those of traditional tangential therapy. Conclusions: While incidental axillary radiation during WBI has been proposed to assist in regional disease control, the TomoDirect plan was demonstrated to decrease this dose, and a hypofractionation scheme would further lower its biological effectiveness. Future clinical studies should incorporate dosimetrical analysis of incidental axillary dose, in order to facilitate hypofractionated IMRT planning with risk-adjusted axilla coverage in early breast cancer. MDPI 2023-06-03 /pmc/articles/PMC10304072/ /pubmed/37374285 http://dx.doi.org/10.3390/medicina59061081 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yeo, Seung-Gu Lim, Cheol Wan Hur, Sung-Mo Kim, Zisun Cho, Kwang Hwan Kim, Min-Jeong Incidental Axillary Dose of Tomotherapy in Hypofractionated Whole Breast Radiotherapy for Early Breast Cancer: A Dosimetrical Analysis |
title | Incidental Axillary Dose of Tomotherapy in Hypofractionated Whole Breast Radiotherapy for Early Breast Cancer: A Dosimetrical Analysis |
title_full | Incidental Axillary Dose of Tomotherapy in Hypofractionated Whole Breast Radiotherapy for Early Breast Cancer: A Dosimetrical Analysis |
title_fullStr | Incidental Axillary Dose of Tomotherapy in Hypofractionated Whole Breast Radiotherapy for Early Breast Cancer: A Dosimetrical Analysis |
title_full_unstemmed | Incidental Axillary Dose of Tomotherapy in Hypofractionated Whole Breast Radiotherapy for Early Breast Cancer: A Dosimetrical Analysis |
title_short | Incidental Axillary Dose of Tomotherapy in Hypofractionated Whole Breast Radiotherapy for Early Breast Cancer: A Dosimetrical Analysis |
title_sort | incidental axillary dose of tomotherapy in hypofractionated whole breast radiotherapy for early breast cancer: a dosimetrical analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304072/ https://www.ncbi.nlm.nih.gov/pubmed/37374285 http://dx.doi.org/10.3390/medicina59061081 |
work_keys_str_mv | AT yeoseunggu incidentalaxillarydoseoftomotherapyinhypofractionatedwholebreastradiotherapyforearlybreastcanceradosimetricalanalysis AT limcheolwan incidentalaxillarydoseoftomotherapyinhypofractionatedwholebreastradiotherapyforearlybreastcanceradosimetricalanalysis AT hursungmo incidentalaxillarydoseoftomotherapyinhypofractionatedwholebreastradiotherapyforearlybreastcanceradosimetricalanalysis AT kimzisun incidentalaxillarydoseoftomotherapyinhypofractionatedwholebreastradiotherapyforearlybreastcanceradosimetricalanalysis AT chokwanghwan incidentalaxillarydoseoftomotherapyinhypofractionatedwholebreastradiotherapyforearlybreastcanceradosimetricalanalysis AT kimminjeong incidentalaxillarydoseoftomotherapyinhypofractionatedwholebreastradiotherapyforearlybreastcanceradosimetricalanalysis |