Cargando…

Minimizing Area-Specific Resistance of Electrochemical Hydrogen Compressor under Various Operating Conditions Using Unsteady 3D Single-Channel Model

Extensive research has been conducted over the past few decades on carbon-free hydrogen energy. Hydrogen, being an abundant energy source, requires high-pressure compression for storage and transportation due to its low volumetric density. Mechanical and electrochemical compression are two common me...

Descripción completa

Detalles Bibliográficos
Autores principales: Gong, Myungkeun, Jin, Changhyun, Na, Youngseung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304108/
https://www.ncbi.nlm.nih.gov/pubmed/37367759
http://dx.doi.org/10.3390/membranes13060555
_version_ 1785065430102048768
author Gong, Myungkeun
Jin, Changhyun
Na, Youngseung
author_facet Gong, Myungkeun
Jin, Changhyun
Na, Youngseung
author_sort Gong, Myungkeun
collection PubMed
description Extensive research has been conducted over the past few decades on carbon-free hydrogen energy. Hydrogen, being an abundant energy source, requires high-pressure compression for storage and transportation due to its low volumetric density. Mechanical and electrochemical compression are two common methods used to compress hydrogen under high pressure. Mechanical compressors can potentially cause contamination due to the lubricating oil when compressing hydrogen, whereas electrochemical hydrogen compressors (EHCs) can produce high-purity, high-pressure hydrogen without any moving parts. A study was conducted using a 3D single-channel EHC model focusing on the water content and area-specific resistance of the membrane under various temperature, relative humidity, and gas diffusion layer (GDL) porosity conditions. Numerical analysis demonstrated that the higher the operating temperature, the higher the water content in the membrane. This is because the saturation vapor pressure increases with higher temperatures. When dry hydrogen is supplied to a sufficiently humidified membrane, the actual water vapor pressure decreases, leading to an increase in the membrane’s area-specific resistance. Furthermore, with a low GDL porosity, the viscous resistance increases, hindering the smooth supply of humidified hydrogen to the membrane. Through a transient analysis of an EHC, favorable operating conditions for rapidly hydrating membranes were identified.
format Online
Article
Text
id pubmed-10304108
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103041082023-06-29 Minimizing Area-Specific Resistance of Electrochemical Hydrogen Compressor under Various Operating Conditions Using Unsteady 3D Single-Channel Model Gong, Myungkeun Jin, Changhyun Na, Youngseung Membranes (Basel) Article Extensive research has been conducted over the past few decades on carbon-free hydrogen energy. Hydrogen, being an abundant energy source, requires high-pressure compression for storage and transportation due to its low volumetric density. Mechanical and electrochemical compression are two common methods used to compress hydrogen under high pressure. Mechanical compressors can potentially cause contamination due to the lubricating oil when compressing hydrogen, whereas electrochemical hydrogen compressors (EHCs) can produce high-purity, high-pressure hydrogen without any moving parts. A study was conducted using a 3D single-channel EHC model focusing on the water content and area-specific resistance of the membrane under various temperature, relative humidity, and gas diffusion layer (GDL) porosity conditions. Numerical analysis demonstrated that the higher the operating temperature, the higher the water content in the membrane. This is because the saturation vapor pressure increases with higher temperatures. When dry hydrogen is supplied to a sufficiently humidified membrane, the actual water vapor pressure decreases, leading to an increase in the membrane’s area-specific resistance. Furthermore, with a low GDL porosity, the viscous resistance increases, hindering the smooth supply of humidified hydrogen to the membrane. Through a transient analysis of an EHC, favorable operating conditions for rapidly hydrating membranes were identified. MDPI 2023-05-26 /pmc/articles/PMC10304108/ /pubmed/37367759 http://dx.doi.org/10.3390/membranes13060555 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gong, Myungkeun
Jin, Changhyun
Na, Youngseung
Minimizing Area-Specific Resistance of Electrochemical Hydrogen Compressor under Various Operating Conditions Using Unsteady 3D Single-Channel Model
title Minimizing Area-Specific Resistance of Electrochemical Hydrogen Compressor under Various Operating Conditions Using Unsteady 3D Single-Channel Model
title_full Minimizing Area-Specific Resistance of Electrochemical Hydrogen Compressor under Various Operating Conditions Using Unsteady 3D Single-Channel Model
title_fullStr Minimizing Area-Specific Resistance of Electrochemical Hydrogen Compressor under Various Operating Conditions Using Unsteady 3D Single-Channel Model
title_full_unstemmed Minimizing Area-Specific Resistance of Electrochemical Hydrogen Compressor under Various Operating Conditions Using Unsteady 3D Single-Channel Model
title_short Minimizing Area-Specific Resistance of Electrochemical Hydrogen Compressor under Various Operating Conditions Using Unsteady 3D Single-Channel Model
title_sort minimizing area-specific resistance of electrochemical hydrogen compressor under various operating conditions using unsteady 3d single-channel model
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304108/
https://www.ncbi.nlm.nih.gov/pubmed/37367759
http://dx.doi.org/10.3390/membranes13060555
work_keys_str_mv AT gongmyungkeun minimizingareaspecificresistanceofelectrochemicalhydrogencompressorundervariousoperatingconditionsusingunsteady3dsinglechannelmodel
AT jinchanghyun minimizingareaspecificresistanceofelectrochemicalhydrogencompressorundervariousoperatingconditionsusingunsteady3dsinglechannelmodel
AT nayoungseung minimizingareaspecificresistanceofelectrochemicalhydrogencompressorundervariousoperatingconditionsusingunsteady3dsinglechannelmodel