Cargando…

Learning Effects in Air Displacement Plethysmography

Air displacement plethysmography (ADP) is a widespread technique for assessing global obesity in both health and disease. The reliability of ADP has been demonstrated by studies focused on duplicate trials. The present study was purported to evaluate learning effects on the reliability of body compo...

Descripción completa

Detalles Bibliográficos
Autores principales: Muntean, Paul, Popa, Anca, Miclos-Balica, Monica, Schick, Falk, Munteanu, Oana, Pupazan, Vasile, Neagu, Adrian, Neagu, Monica
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304159/
https://www.ncbi.nlm.nih.gov/pubmed/37374098
http://dx.doi.org/10.3390/life13061315
_version_ 1785065441720270848
author Muntean, Paul
Popa, Anca
Miclos-Balica, Monica
Schick, Falk
Munteanu, Oana
Pupazan, Vasile
Neagu, Adrian
Neagu, Monica
author_facet Muntean, Paul
Popa, Anca
Miclos-Balica, Monica
Schick, Falk
Munteanu, Oana
Pupazan, Vasile
Neagu, Adrian
Neagu, Monica
author_sort Muntean, Paul
collection PubMed
description Air displacement plethysmography (ADP) is a widespread technique for assessing global obesity in both health and disease. The reliability of ADP has been demonstrated by studies focused on duplicate trials. The present study was purported to evaluate learning effects on the reliability of body composition assessment using the BOD POD system, the sole commercially available ADP instrument. To this end, quadruplicate trials were performed on a group of 105 subjects (51 women and 54 men). We estimated measurement error from pairs of consecutive trials—(1,2), (2,3), and (3,4)—to test the hypothesis that early measurements are subject to larger errors. Indeed, statistical analysis revealed that measures of reliability inferred from the first two trials were inferior to those computed for the other pairs of contiguous trials: for percent body fat (%BF), the standard error of measurement (SEM) was 1.04% for pair (1,2), 0.71% for pair (2,3), and 0.66% for pair (3,4); the two-way random effects model intraclass correlation coefficient (ICC) was 0.991 for pair (1,2), and 0.996 for pairs (2,3) and (3,4). Our findings suggest that, at least for novice subjects, the first ADP test should be regarded as a practice trial. When the remaining trials were pooled together, the reliability indices of single ADP tests were the following: ICC = 0.996, SEM = 0.70%, and minimum detectable change (MDC) = 1.93% for %BF, and ICC = 0.999, SEM = 0.49 kg, and MDC = 1.35 kg for fat-free mass (FFM). Thus, the present study pleads for eliminating learning effects to further increase the reliability of ADP.
format Online
Article
Text
id pubmed-10304159
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103041592023-06-29 Learning Effects in Air Displacement Plethysmography Muntean, Paul Popa, Anca Miclos-Balica, Monica Schick, Falk Munteanu, Oana Pupazan, Vasile Neagu, Adrian Neagu, Monica Life (Basel) Article Air displacement plethysmography (ADP) is a widespread technique for assessing global obesity in both health and disease. The reliability of ADP has been demonstrated by studies focused on duplicate trials. The present study was purported to evaluate learning effects on the reliability of body composition assessment using the BOD POD system, the sole commercially available ADP instrument. To this end, quadruplicate trials were performed on a group of 105 subjects (51 women and 54 men). We estimated measurement error from pairs of consecutive trials—(1,2), (2,3), and (3,4)—to test the hypothesis that early measurements are subject to larger errors. Indeed, statistical analysis revealed that measures of reliability inferred from the first two trials were inferior to those computed for the other pairs of contiguous trials: for percent body fat (%BF), the standard error of measurement (SEM) was 1.04% for pair (1,2), 0.71% for pair (2,3), and 0.66% for pair (3,4); the two-way random effects model intraclass correlation coefficient (ICC) was 0.991 for pair (1,2), and 0.996 for pairs (2,3) and (3,4). Our findings suggest that, at least for novice subjects, the first ADP test should be regarded as a practice trial. When the remaining trials were pooled together, the reliability indices of single ADP tests were the following: ICC = 0.996, SEM = 0.70%, and minimum detectable change (MDC) = 1.93% for %BF, and ICC = 0.999, SEM = 0.49 kg, and MDC = 1.35 kg for fat-free mass (FFM). Thus, the present study pleads for eliminating learning effects to further increase the reliability of ADP. MDPI 2023-06-02 /pmc/articles/PMC10304159/ /pubmed/37374098 http://dx.doi.org/10.3390/life13061315 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Muntean, Paul
Popa, Anca
Miclos-Balica, Monica
Schick, Falk
Munteanu, Oana
Pupazan, Vasile
Neagu, Adrian
Neagu, Monica
Learning Effects in Air Displacement Plethysmography
title Learning Effects in Air Displacement Plethysmography
title_full Learning Effects in Air Displacement Plethysmography
title_fullStr Learning Effects in Air Displacement Plethysmography
title_full_unstemmed Learning Effects in Air Displacement Plethysmography
title_short Learning Effects in Air Displacement Plethysmography
title_sort learning effects in air displacement plethysmography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304159/
https://www.ncbi.nlm.nih.gov/pubmed/37374098
http://dx.doi.org/10.3390/life13061315
work_keys_str_mv AT munteanpaul learningeffectsinairdisplacementplethysmography
AT popaanca learningeffectsinairdisplacementplethysmography
AT miclosbalicamonica learningeffectsinairdisplacementplethysmography
AT schickfalk learningeffectsinairdisplacementplethysmography
AT munteanuoana learningeffectsinairdisplacementplethysmography
AT pupazanvasile learningeffectsinairdisplacementplethysmography
AT neaguadrian learningeffectsinairdisplacementplethysmography
AT neagumonica learningeffectsinairdisplacementplethysmography