Cargando…
Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel
Immunoassays, which use antigen–antibody reactions, are the primary techniques used to selectively quantify specific disease markers in blood. Conventional immunoassays, such as the microplate-based enzyme-linked immunosorbent assay (ELISA) and paper-based immunochromatography, are widely used, but...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304311/ https://www.ncbi.nlm.nih.gov/pubmed/37375188 http://dx.doi.org/10.3390/molecules28124635 |
_version_ | 1785065476818206720 |
---|---|
author | Banno, Yuto Nomiyama, Takuma Okuno, Shoma Ide, Sachiko Kaji, Noritada |
author_facet | Banno, Yuto Nomiyama, Takuma Okuno, Shoma Ide, Sachiko Kaji, Noritada |
author_sort | Banno, Yuto |
collection | PubMed |
description | Immunoassays, which use antigen–antibody reactions, are the primary techniques used to selectively quantify specific disease markers in blood. Conventional immunoassays, such as the microplate-based enzyme-linked immunosorbent assay (ELISA) and paper-based immunochromatography, are widely used, but they have advantages and disadvantages in terms of sensitivity and operating time. Therefore, in recent years, microfluidic-chip-based immunoassay devices with high sensitivity, rapidity and simplicity, which are compatible with whole blood assays and multiplex assays, have been actively investigated. In this study, we developed a microfluidic device using gelatin methacryloyl (GelMA) hydrogel to form a wall-like structure in a microfluidic channel and perform immunoassays inside the wall-like structure, which can be used for rapid and highly sensitive multiplex assays with extremely small sample amounts of ~1 μL. The characteristics of GelMA hydrogel, such as swelling rate, optical absorption and fluorescence spectra, and morphology, were carefully studied to adapt the iImmunowall device and immunoassay. Using this device, a quantitative analysis of interleukin-4 (IL-4), a biomarker of chronic inflammatory diseases, was performed and a limit of detection (LOD) of 0.98 ng/mL was achieved with only 1 μL sample and 25 min incubation time. The superior optical transparency over a wide range of wavelengths and lack of autofluorescence will help to expand the application field of the iImmunowall device, such as to a simultaneous multiple assay in a single microfluidic channel, and provide a fast and cost-effective immunoassay method. |
format | Online Article Text |
id | pubmed-10304311 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-103043112023-06-29 Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel Banno, Yuto Nomiyama, Takuma Okuno, Shoma Ide, Sachiko Kaji, Noritada Molecules Communication Immunoassays, which use antigen–antibody reactions, are the primary techniques used to selectively quantify specific disease markers in blood. Conventional immunoassays, such as the microplate-based enzyme-linked immunosorbent assay (ELISA) and paper-based immunochromatography, are widely used, but they have advantages and disadvantages in terms of sensitivity and operating time. Therefore, in recent years, microfluidic-chip-based immunoassay devices with high sensitivity, rapidity and simplicity, which are compatible with whole blood assays and multiplex assays, have been actively investigated. In this study, we developed a microfluidic device using gelatin methacryloyl (GelMA) hydrogel to form a wall-like structure in a microfluidic channel and perform immunoassays inside the wall-like structure, which can be used for rapid and highly sensitive multiplex assays with extremely small sample amounts of ~1 μL. The characteristics of GelMA hydrogel, such as swelling rate, optical absorption and fluorescence spectra, and morphology, were carefully studied to adapt the iImmunowall device and immunoassay. Using this device, a quantitative analysis of interleukin-4 (IL-4), a biomarker of chronic inflammatory diseases, was performed and a limit of detection (LOD) of 0.98 ng/mL was achieved with only 1 μL sample and 25 min incubation time. The superior optical transparency over a wide range of wavelengths and lack of autofluorescence will help to expand the application field of the iImmunowall device, such as to a simultaneous multiple assay in a single microfluidic channel, and provide a fast and cost-effective immunoassay method. MDPI 2023-06-08 /pmc/articles/PMC10304311/ /pubmed/37375188 http://dx.doi.org/10.3390/molecules28124635 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Banno, Yuto Nomiyama, Takuma Okuno, Shoma Ide, Sachiko Kaji, Noritada Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel |
title | Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel |
title_full | Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel |
title_fullStr | Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel |
title_full_unstemmed | Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel |
title_short | Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel |
title_sort | quantitative evaluation of interleukin-4 by immunowall devices made of gelatin methacryloyl hydrogel |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304311/ https://www.ncbi.nlm.nih.gov/pubmed/37375188 http://dx.doi.org/10.3390/molecules28124635 |
work_keys_str_mv | AT bannoyuto quantitativeevaluationofinterleukin4byimmunowalldevicesmadeofgelatinmethacryloylhydrogel AT nomiyamatakuma quantitativeevaluationofinterleukin4byimmunowalldevicesmadeofgelatinmethacryloylhydrogel AT okunoshoma quantitativeevaluationofinterleukin4byimmunowalldevicesmadeofgelatinmethacryloylhydrogel AT idesachiko quantitativeevaluationofinterleukin4byimmunowalldevicesmadeofgelatinmethacryloylhydrogel AT kajinoritada quantitativeevaluationofinterleukin4byimmunowalldevicesmadeofgelatinmethacryloylhydrogel |