Cargando…

Applicability of the Meniscus-Removal Method for Q-Band Liquid Characterization in Semi-Open Waveguide Cell †

We present the broadband transmission-reflection meniscus-removal method for liquid characterization in a semi-open rectangular waveguide. The algorithm utilizes 2-port scattering parameters measured with a calibrated vector network analyzer for three states of the measurement cell: empty and filled...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalisiak, Michał, Wiatr, Wojciech, Papis, Radosław
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304776/
https://www.ncbi.nlm.nih.gov/pubmed/37420556
http://dx.doi.org/10.3390/s23125390
_version_ 1785065585081581568
author Kalisiak, Michał
Wiatr, Wojciech
Papis, Radosław
author_facet Kalisiak, Michał
Wiatr, Wojciech
Papis, Radosław
author_sort Kalisiak, Michał
collection PubMed
description We present the broadband transmission-reflection meniscus-removal method for liquid characterization in a semi-open rectangular waveguide. The algorithm utilizes 2-port scattering parameters measured with a calibrated vector network analyzer for three states of the measurement cell: empty and filled with two liquid levels. The method enables the mathematical de-embedding of a symmetrical sample of a liquid, not distorted with a meniscus, and provision of its permittivity and permeability, as well as its height. We validate the method for propan-2-ol (IPA), a 50% aqueous solution of IPA, and distilled water in the Q-band (33–50 GHz). We investigate typical problems for in-waveguide measurements, such as phase ambiguity.
format Online
Article
Text
id pubmed-10304776
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-103047762023-06-29 Applicability of the Meniscus-Removal Method for Q-Band Liquid Characterization in Semi-Open Waveguide Cell † Kalisiak, Michał Wiatr, Wojciech Papis, Radosław Sensors (Basel) Communication We present the broadband transmission-reflection meniscus-removal method for liquid characterization in a semi-open rectangular waveguide. The algorithm utilizes 2-port scattering parameters measured with a calibrated vector network analyzer for three states of the measurement cell: empty and filled with two liquid levels. The method enables the mathematical de-embedding of a symmetrical sample of a liquid, not distorted with a meniscus, and provision of its permittivity and permeability, as well as its height. We validate the method for propan-2-ol (IPA), a 50% aqueous solution of IPA, and distilled water in the Q-band (33–50 GHz). We investigate typical problems for in-waveguide measurements, such as phase ambiguity. MDPI 2023-06-07 /pmc/articles/PMC10304776/ /pubmed/37420556 http://dx.doi.org/10.3390/s23125390 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Kalisiak, Michał
Wiatr, Wojciech
Papis, Radosław
Applicability of the Meniscus-Removal Method for Q-Band Liquid Characterization in Semi-Open Waveguide Cell †
title Applicability of the Meniscus-Removal Method for Q-Band Liquid Characterization in Semi-Open Waveguide Cell †
title_full Applicability of the Meniscus-Removal Method for Q-Band Liquid Characterization in Semi-Open Waveguide Cell †
title_fullStr Applicability of the Meniscus-Removal Method for Q-Band Liquid Characterization in Semi-Open Waveguide Cell †
title_full_unstemmed Applicability of the Meniscus-Removal Method for Q-Band Liquid Characterization in Semi-Open Waveguide Cell †
title_short Applicability of the Meniscus-Removal Method for Q-Band Liquid Characterization in Semi-Open Waveguide Cell †
title_sort applicability of the meniscus-removal method for q-band liquid characterization in semi-open waveguide cell †
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10304776/
https://www.ncbi.nlm.nih.gov/pubmed/37420556
http://dx.doi.org/10.3390/s23125390
work_keys_str_mv AT kalisiakmichał applicabilityofthemeniscusremovalmethodforqbandliquidcharacterizationinsemiopenwaveguidecell
AT wiatrwojciech applicabilityofthemeniscusremovalmethodforqbandliquidcharacterizationinsemiopenwaveguidecell
AT papisradosław applicabilityofthemeniscusremovalmethodforqbandliquidcharacterizationinsemiopenwaveguidecell