Cargando…
Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
INTRODUCTION: The European Society of Gastrointestinal Endoscopy (ESGE) identified the need to benchmark the quality of small bowel capsule endoscopy (SBCE) and produced a set of performance measures (PM). The aim of this study is to critically evaluate the accordance of the PM for SBCE in two Portu...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
S. Karger AG
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10305259/ https://www.ncbi.nlm.nih.gov/pubmed/37387712 http://dx.doi.org/10.1159/000523773 |
_version_ | 1785065691301281792 |
---|---|
author | Gomes, Catarina O'Neill, Catarina Pinho, Rolando Barosa, Rita Ponte, Ana Magalhães-Costa, Pedro Rodrigues, Adélia Chagas, Cristina Carvalho, João |
author_facet | Gomes, Catarina O'Neill, Catarina Pinho, Rolando Barosa, Rita Ponte, Ana Magalhães-Costa, Pedro Rodrigues, Adélia Chagas, Cristina Carvalho, João |
author_sort | Gomes, Catarina |
collection | PubMed |
description | INTRODUCTION: The European Society of Gastrointestinal Endoscopy (ESGE) identified the need to benchmark the quality of small bowel capsule endoscopy (SBCE) and produced a set of performance measures (PM). The aim of this study is to critically evaluate the accordance of the PM for SBCE in two Portuguese centers with different SBCE platforms. METHODS: The authors conducted a cross-sectional analysis of consecutive SBCE performed in an 18-month period in 2 Portuguese centers that used two different SBCE platforms Mirocam® (IntroMedic, Seoul, South Korea) and PillCam® (Medtronic, Yokneam, Israel). A total of 10 PM (6 key, 4 minor) were evaluated and compared between the 2 centers. RESULTS: A total of 493 SBCE were included. The minimum standard established by ESGE was reached in 3/6 key PM (complete visualization, lesion detection rate, and capsule retention rate), and none of the 4 minor PM. PM compliance significantly differed between the 2 centers: complete small bowel visualization 95.9 and 90% (p = 0.01), diagnostic yield 50.6 and 63% (p = 0.005), adequate small bowel cleansing level according to Brotz scale 69.54 and 84.6% (p ≤ 0.001), patients with high risk of capsule retention offered a patency capsule 4.2 and 73% (p ≤ 0.001), respectively. CONCLUSION: This study highlights and critically discusses technical and organizational issues that should be considered in defining more realistic PM thresholds, aiming to improve SBCE quality. |
format | Online Article Text |
id | pubmed-10305259 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | S. Karger AG |
record_format | MEDLINE/PubMed |
spelling | pubmed-103052592023-06-29 Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms Gomes, Catarina O'Neill, Catarina Pinho, Rolando Barosa, Rita Ponte, Ana Magalhães-Costa, Pedro Rodrigues, Adélia Chagas, Cristina Carvalho, João GE Port J Gastroenterol Research Article INTRODUCTION: The European Society of Gastrointestinal Endoscopy (ESGE) identified the need to benchmark the quality of small bowel capsule endoscopy (SBCE) and produced a set of performance measures (PM). The aim of this study is to critically evaluate the accordance of the PM for SBCE in two Portuguese centers with different SBCE platforms. METHODS: The authors conducted a cross-sectional analysis of consecutive SBCE performed in an 18-month period in 2 Portuguese centers that used two different SBCE platforms Mirocam® (IntroMedic, Seoul, South Korea) and PillCam® (Medtronic, Yokneam, Israel). A total of 10 PM (6 key, 4 minor) were evaluated and compared between the 2 centers. RESULTS: A total of 493 SBCE were included. The minimum standard established by ESGE was reached in 3/6 key PM (complete visualization, lesion detection rate, and capsule retention rate), and none of the 4 minor PM. PM compliance significantly differed between the 2 centers: complete small bowel visualization 95.9 and 90% (p = 0.01), diagnostic yield 50.6 and 63% (p = 0.005), adequate small bowel cleansing level according to Brotz scale 69.54 and 84.6% (p ≤ 0.001), patients with high risk of capsule retention offered a patency capsule 4.2 and 73% (p ≤ 0.001), respectively. CONCLUSION: This study highlights and critically discusses technical and organizational issues that should be considered in defining more realistic PM thresholds, aiming to improve SBCE quality. S. Karger AG 2022-05-16 /pmc/articles/PMC10305259/ /pubmed/37387712 http://dx.doi.org/10.1159/000523773 Text en Copyright © 2022 by The Author(s). Published by S. Karger AG, Basel https://creativecommons.org/licenses/by-nc/4.0/This article is licensed under the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC). Usage and distribution for commercial purposes requires written permission. |
spellingShingle | Research Article Gomes, Catarina O'Neill, Catarina Pinho, Rolando Barosa, Rita Ponte, Ana Magalhães-Costa, Pedro Rodrigues, Adélia Chagas, Cristina Carvalho, João Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms |
title | Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms |
title_full | Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms |
title_fullStr | Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms |
title_full_unstemmed | Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms |
title_short | Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms |
title_sort | critical analysis of the applicability of small bowel capsule endoscopy performance measures among 2 portuguese centers with different capsule endoscopy platforms |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10305259/ https://www.ncbi.nlm.nih.gov/pubmed/37387712 http://dx.doi.org/10.1159/000523773 |
work_keys_str_mv | AT gomescatarina criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms AT oneillcatarina criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms AT pinhorolando criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms AT barosarita criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms AT ponteana criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms AT magalhaescostapedro criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms AT rodriguesadelia criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms AT chagascristina criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms AT carvalhojoao criticalanalysisoftheapplicabilityofsmallbowelcapsuleendoscopyperformancemeasuresamong2portuguesecenterswithdifferentcapsuleendoscopyplatforms |