Cargando…

Comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – A cone-beam computed tomography study

CONTEXT: The purpose of this study was to evaluate and compare the centering ability and canal transportation of TruNatomy, OneCurve, and Jizai file systems to assess their performance in oval-shaped canals using cone-beam computed tomography imaging. MATERIALS AND METHODS: Forty-two fully formed si...

Descripción completa

Detalles Bibliográficos
Autores principales: Manocha, Simar Kaur, Saha, Suparna Ganguly, Agarwal, Rolly S., Vijaywargiya, Neelam, Saha, Mainak Kanti, Surana, Anjali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10309135/
https://www.ncbi.nlm.nih.gov/pubmed/37398864
http://dx.doi.org/10.4103/jcd.jcd_98_23
_version_ 1785066388113588224
author Manocha, Simar Kaur
Saha, Suparna Ganguly
Agarwal, Rolly S.
Vijaywargiya, Neelam
Saha, Mainak Kanti
Surana, Anjali
author_facet Manocha, Simar Kaur
Saha, Suparna Ganguly
Agarwal, Rolly S.
Vijaywargiya, Neelam
Saha, Mainak Kanti
Surana, Anjali
author_sort Manocha, Simar Kaur
collection PubMed
description CONTEXT: The purpose of this study was to evaluate and compare the centering ability and canal transportation of TruNatomy, OneCurve, and Jizai file systems to assess their performance in oval-shaped canals using cone-beam computed tomography imaging. MATERIALS AND METHODS: Forty-two fully formed single-rooted mandibular premolars were selected with a buccolingual canal size 2–2.5 times the mesiodistal size at 5 mm from the apex, with 0°–10° canal curvature with a 5–6 mm radius, at 5 mm from the apex. The teeth were divided into three groups (n = 14) and prepared with TruNatomy, OneCurve, and Jizai files based on the manufacturer's instructions. Cone-beam computed tomographic images were taken before and after instrumentation. The canal transportation and centering ability was calculated at 3, 6, and 9 mm from the apex in both mesiodistal and buccolingual directions. STATISTICAL ANALYSIS: Intergroup comparison was done using Kolmogorov–Smirnov test. Intragroup comparison was done using Freidman test. A comparison of categorical variables was done using the Chi-square test. RESULTS: The results obtained did not present any statistically significant difference between the three groups, with TruNatomy and OneCurve showing relatively lesser canal transportation and better centering ratio when compared to the Jizai file system. CONCLUSIONS: It can, therefore, be concluded that all three systems used in the study are capable of safely preparing root canals with minimal errors.
format Online
Article
Text
id pubmed-10309135
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-103091352023-06-30 Comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – A cone-beam computed tomography study Manocha, Simar Kaur Saha, Suparna Ganguly Agarwal, Rolly S. Vijaywargiya, Neelam Saha, Mainak Kanti Surana, Anjali J Conserv Dent Original Article CONTEXT: The purpose of this study was to evaluate and compare the centering ability and canal transportation of TruNatomy, OneCurve, and Jizai file systems to assess their performance in oval-shaped canals using cone-beam computed tomography imaging. MATERIALS AND METHODS: Forty-two fully formed single-rooted mandibular premolars were selected with a buccolingual canal size 2–2.5 times the mesiodistal size at 5 mm from the apex, with 0°–10° canal curvature with a 5–6 mm radius, at 5 mm from the apex. The teeth were divided into three groups (n = 14) and prepared with TruNatomy, OneCurve, and Jizai files based on the manufacturer's instructions. Cone-beam computed tomographic images were taken before and after instrumentation. The canal transportation and centering ability was calculated at 3, 6, and 9 mm from the apex in both mesiodistal and buccolingual directions. STATISTICAL ANALYSIS: Intergroup comparison was done using Kolmogorov–Smirnov test. Intragroup comparison was done using Freidman test. A comparison of categorical variables was done using the Chi-square test. RESULTS: The results obtained did not present any statistically significant difference between the three groups, with TruNatomy and OneCurve showing relatively lesser canal transportation and better centering ratio when compared to the Jizai file system. CONCLUSIONS: It can, therefore, be concluded that all three systems used in the study are capable of safely preparing root canals with minimal errors. Wolters Kluwer - Medknow 2023 2023-05-16 /pmc/articles/PMC10309135/ /pubmed/37398864 http://dx.doi.org/10.4103/jcd.jcd_98_23 Text en Copyright: © 2023 Journal of Conservative Dentistry https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Manocha, Simar Kaur
Saha, Suparna Ganguly
Agarwal, Rolly S.
Vijaywargiya, Neelam
Saha, Mainak Kanti
Surana, Anjali
Comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – A cone-beam computed tomography study
title Comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – A cone-beam computed tomography study
title_full Comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – A cone-beam computed tomography study
title_fullStr Comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – A cone-beam computed tomography study
title_full_unstemmed Comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – A cone-beam computed tomography study
title_short Comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – A cone-beam computed tomography study
title_sort comparative evaluation of canal transportation and canal centering ability in oval canals with newer nickel–titanium rotary single file systems – a cone-beam computed tomography study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10309135/
https://www.ncbi.nlm.nih.gov/pubmed/37398864
http://dx.doi.org/10.4103/jcd.jcd_98_23
work_keys_str_mv AT manochasimarkaur comparativeevaluationofcanaltransportationandcanalcenteringabilityinovalcanalswithnewernickeltitaniumrotarysinglefilesystemsaconebeamcomputedtomographystudy
AT sahasuparnaganguly comparativeevaluationofcanaltransportationandcanalcenteringabilityinovalcanalswithnewernickeltitaniumrotarysinglefilesystemsaconebeamcomputedtomographystudy
AT agarwalrollys comparativeevaluationofcanaltransportationandcanalcenteringabilityinovalcanalswithnewernickeltitaniumrotarysinglefilesystemsaconebeamcomputedtomographystudy
AT vijaywargiyaneelam comparativeevaluationofcanaltransportationandcanalcenteringabilityinovalcanalswithnewernickeltitaniumrotarysinglefilesystemsaconebeamcomputedtomographystudy
AT sahamainakkanti comparativeevaluationofcanaltransportationandcanalcenteringabilityinovalcanalswithnewernickeltitaniumrotarysinglefilesystemsaconebeamcomputedtomographystudy
AT suranaanjali comparativeevaluationofcanaltransportationandcanalcenteringabilityinovalcanalswithnewernickeltitaniumrotarysinglefilesystemsaconebeamcomputedtomographystudy