Cargando…

Oophoropexy to the Round Ligament after Recurrent Adnexal Torsion

Recurrent adnexal torsion is a rare gynecological emergency. We report a case of recurrent ipsilateral adnexal torsion in a woman with polycystic ovaries, previously submitted to a laparoscopic plication of the utero-ovarian ligament. Due to the recurrence after the plication of the utero-ovarian li...

Descripción completa

Detalles Bibliográficos
Autores principales: Gonçalves, Inês Sarmento, Sampaio, Joana, Félix, Joana, Silva, Ana Catarina, Fornelos, Gisela, Silva, Pedro Tiago
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Revinter Publicações Ltda 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10309351/
https://www.ncbi.nlm.nih.gov/pubmed/30308681
http://dx.doi.org/10.1055/s-0038-1673426
_version_ 1785066430696259584
author Gonçalves, Inês Sarmento
Sampaio, Joana
Félix, Joana
Silva, Ana Catarina
Fornelos, Gisela
Silva, Pedro Tiago
author_facet Gonçalves, Inês Sarmento
Sampaio, Joana
Félix, Joana
Silva, Ana Catarina
Fornelos, Gisela
Silva, Pedro Tiago
author_sort Gonçalves, Inês Sarmento
collection PubMed
description Recurrent adnexal torsion is a rare gynecological emergency. We report a case of recurrent ipsilateral adnexal torsion in a woman with polycystic ovaries, previously submitted to a laparoscopic plication of the utero-ovarian ligament. Due to the recurrence after the plication of the utero-ovarian ligament, the authors performed a laparoscopic oophoropexy to the round ligament, which is an underreported procedure. The patient was asymptomatic for 1 year, after which she had a new recurrence and needed a unilateral laparoscopic adnexectomy. Since then, she regained the quality of life without any gynecological symptoms. Oophoropexy to the round ligament may be considered when other techniques fail or, perhaps, as a first option in selected cases of adnexal torsion, as it may allow the prevention of recurrence without increasing morbidity while preserving the adnexa.
format Online
Article
Text
id pubmed-10309351
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Thieme Revinter Publicações Ltda
record_format MEDLINE/PubMed
spelling pubmed-103093512023-07-27 Oophoropexy to the Round Ligament after Recurrent Adnexal Torsion Gonçalves, Inês Sarmento Sampaio, Joana Félix, Joana Silva, Ana Catarina Fornelos, Gisela Silva, Pedro Tiago Rev Bras Ginecol Obstet Recurrent adnexal torsion is a rare gynecological emergency. We report a case of recurrent ipsilateral adnexal torsion in a woman with polycystic ovaries, previously submitted to a laparoscopic plication of the utero-ovarian ligament. Due to the recurrence after the plication of the utero-ovarian ligament, the authors performed a laparoscopic oophoropexy to the round ligament, which is an underreported procedure. The patient was asymptomatic for 1 year, after which she had a new recurrence and needed a unilateral laparoscopic adnexectomy. Since then, she regained the quality of life without any gynecological symptoms. Oophoropexy to the round ligament may be considered when other techniques fail or, perhaps, as a first option in selected cases of adnexal torsion, as it may allow the prevention of recurrence without increasing morbidity while preserving the adnexa. Thieme Revinter Publicações Ltda 2018-10-11 2018-11 /pmc/articles/PMC10309351/ /pubmed/30308681 http://dx.doi.org/10.1055/s-0038-1673426 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Gonçalves, Inês Sarmento
Sampaio, Joana
Félix, Joana
Silva, Ana Catarina
Fornelos, Gisela
Silva, Pedro Tiago
Oophoropexy to the Round Ligament after Recurrent Adnexal Torsion
title Oophoropexy to the Round Ligament after Recurrent Adnexal Torsion
title_full Oophoropexy to the Round Ligament after Recurrent Adnexal Torsion
title_fullStr Oophoropexy to the Round Ligament after Recurrent Adnexal Torsion
title_full_unstemmed Oophoropexy to the Round Ligament after Recurrent Adnexal Torsion
title_short Oophoropexy to the Round Ligament after Recurrent Adnexal Torsion
title_sort oophoropexy to the round ligament after recurrent adnexal torsion
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10309351/
https://www.ncbi.nlm.nih.gov/pubmed/30308681
http://dx.doi.org/10.1055/s-0038-1673426
work_keys_str_mv AT goncalvesinessarmento oophoropexytotheroundligamentafterrecurrentadnexaltorsion
AT sampaiojoana oophoropexytotheroundligamentafterrecurrentadnexaltorsion
AT felixjoana oophoropexytotheroundligamentafterrecurrentadnexaltorsion
AT silvaanacatarina oophoropexytotheroundligamentafterrecurrentadnexaltorsion
AT fornelosgisela oophoropexytotheroundligamentafterrecurrentadnexaltorsion
AT silvapedrotiago oophoropexytotheroundligamentafterrecurrentadnexaltorsion