Cargando…
The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system
PURPOSE: To assess the effect of pterygium on corneal densitometry (CD) values. METHODS: One hundred and nine patients (155 eyes) with primary pterygium were divided into a severe pterygium group (79 eyes) and a mild-to-moderate pterygium group (76 eyes) according to pterygium severity. Among them,...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10310544/ https://www.ncbi.nlm.nih.gov/pubmed/37396900 http://dx.doi.org/10.3389/fmed.2023.1184318 |
_version_ | 1785066564427448320 |
---|---|
author | Zhang, Jing Zhang, Liyun Hu, Huiling Sun, Liangnan He, Wenling Zhang, Zhe Wang, Jiantao Nie, Danyao Liu, Xinhua |
author_facet | Zhang, Jing Zhang, Liyun Hu, Huiling Sun, Liangnan He, Wenling Zhang, Zhe Wang, Jiantao Nie, Danyao Liu, Xinhua |
author_sort | Zhang, Jing |
collection | PubMed |
description | PURPOSE: To assess the effect of pterygium on corneal densitometry (CD) values. METHODS: One hundred and nine patients (155 eyes) with primary pterygium were divided into a severe pterygium group (79 eyes) and a mild-to-moderate pterygium group (76 eyes) according to pterygium severity. Among them, 63 patients had monocular pterygium; and 25 patients (38 eyes) underwent pterygium excision combined with conjunctival autograft follow-up. A Pentacam anterior segment analyzer was used to obtain the CD values and corneal morphological parameters, including central corneal thickness (CCT), flat-axis keratometry (K1), steep-axis keratometry (K2), corneal astigmatism, irregular astigmatism, and spherical aberration. CD was subdivided into four concentric radial regions based on corneal diameter and three layers according to depth. RESULTS: CD values at 0–12 mm of the anterior 120 μm layer, 0–10 mm of the center layer and full thickness, and 2–6 mm of the posterior 60 μm layer were significantly higher in eyes affected by pterygium than in the contralateral unaffected eyes (all P < 0.05). CD values were significantly higher in the severe pterygium group than in the mild to moderate pterygium group (all P < 0.05). Corneal astigmatism, irregular astigmatism, K1, K2, CCT, and spherical aberration correlated with CD values in eyes with pterygium (all P < 0.05). CD values at 6–10, 0–12 mm in the anterior 120 μm layer and full thickness, 10–12 and 0–12 mm in the center layer were significantly decreased 1 month after pterygium surgery compared with those before surgery (all P < 0.05). CONCLUSION: Patients with pterygium had increased CD values, particularly in the anterior and central layers. CD values were correlated with pterygium severity grading and corneal parameters. Pterygium surgery partially reduced the CD values. |
format | Online Article Text |
id | pubmed-10310544 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-103105442023-07-01 The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system Zhang, Jing Zhang, Liyun Hu, Huiling Sun, Liangnan He, Wenling Zhang, Zhe Wang, Jiantao Nie, Danyao Liu, Xinhua Front Med (Lausanne) Medicine PURPOSE: To assess the effect of pterygium on corneal densitometry (CD) values. METHODS: One hundred and nine patients (155 eyes) with primary pterygium were divided into a severe pterygium group (79 eyes) and a mild-to-moderate pterygium group (76 eyes) according to pterygium severity. Among them, 63 patients had monocular pterygium; and 25 patients (38 eyes) underwent pterygium excision combined with conjunctival autograft follow-up. A Pentacam anterior segment analyzer was used to obtain the CD values and corneal morphological parameters, including central corneal thickness (CCT), flat-axis keratometry (K1), steep-axis keratometry (K2), corneal astigmatism, irregular astigmatism, and spherical aberration. CD was subdivided into four concentric radial regions based on corneal diameter and three layers according to depth. RESULTS: CD values at 0–12 mm of the anterior 120 μm layer, 0–10 mm of the center layer and full thickness, and 2–6 mm of the posterior 60 μm layer were significantly higher in eyes affected by pterygium than in the contralateral unaffected eyes (all P < 0.05). CD values were significantly higher in the severe pterygium group than in the mild to moderate pterygium group (all P < 0.05). Corneal astigmatism, irregular astigmatism, K1, K2, CCT, and spherical aberration correlated with CD values in eyes with pterygium (all P < 0.05). CD values at 6–10, 0–12 mm in the anterior 120 μm layer and full thickness, 10–12 and 0–12 mm in the center layer were significantly decreased 1 month after pterygium surgery compared with those before surgery (all P < 0.05). CONCLUSION: Patients with pterygium had increased CD values, particularly in the anterior and central layers. CD values were correlated with pterygium severity grading and corneal parameters. Pterygium surgery partially reduced the CD values. Frontiers Media S.A. 2023-06-15 /pmc/articles/PMC10310544/ /pubmed/37396900 http://dx.doi.org/10.3389/fmed.2023.1184318 Text en Copyright © 2023 Zhang, Zhang, Hu, Sun, He, Zhang, Wang, Nie and Liu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Zhang, Jing Zhang, Liyun Hu, Huiling Sun, Liangnan He, Wenling Zhang, Zhe Wang, Jiantao Nie, Danyao Liu, Xinhua The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system |
title | The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system |
title_full | The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system |
title_fullStr | The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system |
title_full_unstemmed | The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system |
title_short | The influence of pterygium on corneal densitometry evaluated using the Oculus Pentacam system |
title_sort | influence of pterygium on corneal densitometry evaluated using the oculus pentacam system |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10310544/ https://www.ncbi.nlm.nih.gov/pubmed/37396900 http://dx.doi.org/10.3389/fmed.2023.1184318 |
work_keys_str_mv | AT zhangjing theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT zhangliyun theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT huhuiling theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT sunliangnan theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT hewenling theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT zhangzhe theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT wangjiantao theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT niedanyao theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT liuxinhua theinfluenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT zhangjing influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT zhangliyun influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT huhuiling influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT sunliangnan influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT hewenling influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT zhangzhe influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT wangjiantao influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT niedanyao influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem AT liuxinhua influenceofpterygiumoncornealdensitometryevaluatedusingtheoculuspentacamsystem |