Cargando…
Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process
Pelvic bone fracture is highly complex, and its anatomical reduction is difficult. Therefore, patient-specific customized plates have been developed using three-dimensional (3D) printing technology and are being increasingly used. In this study, the reduction status in five representative pelvic fra...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10310805/ https://www.ncbi.nlm.nih.gov/pubmed/37386116 http://dx.doi.org/10.1038/s41598-023-37433-1 |
_version_ | 1785066612055867392 |
---|---|
author | Jo, Woo-Lam Chung, Yang-Guk Shin, Seung-Han Lim, Jae-hak Kim, Moo-Sub Yoon, Do-Kun |
author_facet | Jo, Woo-Lam Chung, Yang-Guk Shin, Seung-Han Lim, Jae-hak Kim, Moo-Sub Yoon, Do-Kun |
author_sort | Jo, Woo-Lam |
collection | PubMed |
description | Pelvic bone fracture is highly complex, and its anatomical reduction is difficult. Therefore, patient-specific customized plates have been developed using three-dimensional (3D) printing technology and are being increasingly used. In this study, the reduction status in five representative pelvic fracture models was compared between two groups: the 3D printing plate (3DP) group using a patient-specific 3D printed plate after virtual reduction and the conventional plate (CP) group using a conventional plate by manual bending. The 3DP and CP groups included 10 and 5 cases, respectively. The fractured models were reduced virtually and their non-locking metal plates were customized using 3D printing. The process of contouring the conventional plates to fit the contact surface of the bone with the bending tool was conducted by an experienced pelvic bone trauma surgeon. The reduction and fixation achieved using the two different plate groups was compared, and the significance of differences in the results was analyzed using paired t-tests, after verifying the normality of data distribution. The vertex distances between the surface of the bone and the contact surface of the plate were significantly lower in the 3DP group than in the CP group (0.407 ± 0.342 and 2.195 ± 1.643, respectively, P = 0.008). Length and angular variations, which are measurements of the reduction state, were also lower in the 3DP group than in the CP group (length variation: 3.211 ± 2.497 and 5.493 ± 3.609, respectively, P = 0.051; angular variation: 2.958 ± 1.977 and 4.352 ± 1.947, respectively, P = 0.037). The customized 3D printed plate in the virtual reduction model provided a highly accurate reduction of pelvic bone fractures, suggesting that the customized 3D printed plate may help ensure easy and accurate reduction. |
format | Online Article Text |
id | pubmed-10310805 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-103108052023-07-01 Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process Jo, Woo-Lam Chung, Yang-Guk Shin, Seung-Han Lim, Jae-hak Kim, Moo-Sub Yoon, Do-Kun Sci Rep Article Pelvic bone fracture is highly complex, and its anatomical reduction is difficult. Therefore, patient-specific customized plates have been developed using three-dimensional (3D) printing technology and are being increasingly used. In this study, the reduction status in five representative pelvic fracture models was compared between two groups: the 3D printing plate (3DP) group using a patient-specific 3D printed plate after virtual reduction and the conventional plate (CP) group using a conventional plate by manual bending. The 3DP and CP groups included 10 and 5 cases, respectively. The fractured models were reduced virtually and their non-locking metal plates were customized using 3D printing. The process of contouring the conventional plates to fit the contact surface of the bone with the bending tool was conducted by an experienced pelvic bone trauma surgeon. The reduction and fixation achieved using the two different plate groups was compared, and the significance of differences in the results was analyzed using paired t-tests, after verifying the normality of data distribution. The vertex distances between the surface of the bone and the contact surface of the plate were significantly lower in the 3DP group than in the CP group (0.407 ± 0.342 and 2.195 ± 1.643, respectively, P = 0.008). Length and angular variations, which are measurements of the reduction state, were also lower in the 3DP group than in the CP group (length variation: 3.211 ± 2.497 and 5.493 ± 3.609, respectively, P = 0.051; angular variation: 2.958 ± 1.977 and 4.352 ± 1.947, respectively, P = 0.037). The customized 3D printed plate in the virtual reduction model provided a highly accurate reduction of pelvic bone fractures, suggesting that the customized 3D printed plate may help ensure easy and accurate reduction. Nature Publishing Group UK 2023-06-29 /pmc/articles/PMC10310805/ /pubmed/37386116 http://dx.doi.org/10.1038/s41598-023-37433-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Jo, Woo-Lam Chung, Yang-Guk Shin, Seung-Han Lim, Jae-hak Kim, Moo-Sub Yoon, Do-Kun Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process |
title | Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process |
title_full | Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process |
title_fullStr | Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process |
title_full_unstemmed | Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process |
title_short | Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process |
title_sort | structural analysis of customized 3d printed plate for pelvic bone by comparison with conventional plate based on bending process |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10310805/ https://www.ncbi.nlm.nih.gov/pubmed/37386116 http://dx.doi.org/10.1038/s41598-023-37433-1 |
work_keys_str_mv | AT jowoolam structuralanalysisofcustomized3dprintedplateforpelvicbonebycomparisonwithconventionalplatebasedonbendingprocess AT chungyangguk structuralanalysisofcustomized3dprintedplateforpelvicbonebycomparisonwithconventionalplatebasedonbendingprocess AT shinseunghan structuralanalysisofcustomized3dprintedplateforpelvicbonebycomparisonwithconventionalplatebasedonbendingprocess AT limjaehak structuralanalysisofcustomized3dprintedplateforpelvicbonebycomparisonwithconventionalplatebasedonbendingprocess AT kimmoosub structuralanalysisofcustomized3dprintedplateforpelvicbonebycomparisonwithconventionalplatebasedonbendingprocess AT yoondokun structuralanalysisofcustomized3dprintedplateforpelvicbonebycomparisonwithconventionalplatebasedonbendingprocess |