Additively manufactured test phantoms for mimicking soft tissue radiation attenuation in CBCT using Polyjet technology

OBJECTIVES: To develop and validate a simple approach for building cost-effective imaging phantoms for Cone Beam Computed Tomography (CBCT) using a modified Polyjet additive manufacturing technology where a single material can mimic a range of human soft-tissue radiation attenuation. MATERIALS AND M...

Descripción completa

Detalles Bibliográficos
Autores principales: Hatamikia, Sepideh, Oberoi, Gunpreet, Zacher, Anna, Kronreif, Gernot, Birkfellner, Wolfgang, Kettenbach, Joachim, Ponti, Stefanie, Lorenz, Andrea, Buschmann, Martin, Jaksa, Laszlo, Irnstorfer, Nikolaus, Unger, Ewald
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10311275/
https://www.ncbi.nlm.nih.gov/pubmed/35792011
http://dx.doi.org/10.1016/j.zemedi.2022.05.002
Descripción
Sumario:OBJECTIVES: To develop and validate a simple approach for building cost-effective imaging phantoms for Cone Beam Computed Tomography (CBCT) using a modified Polyjet additive manufacturing technology where a single material can mimic a range of human soft-tissue radiation attenuation. MATERIALS AND METHODS: Single material test phantoms using a cubic lattice were designed in 3-Matic 15.0 software . Keeping the individual cubic lattice volume constant, eight different percentage ratio (R) of air: material from 0% to 70% with a 10% increment were assigned to each sample. The phantoms were printed in three materials, namely Vero PureWhite, VeroClear and TangoPlus using Polyjet technology. The CT value analysis, non-contact profile measurement and microCT-based volumetric analysis was performed for all the samples. RESULTS: The printed test phantoms produced a grey value spectrum equivalent to the radiation attenuation of human soft tissues in the range of −757 to +286 HU on CT. The results from dimensional comparison analysis of the printed phantoms with the digital test phantoms using non-contact profile measurement showed a mean accuracy of 99.07 % and that of micro-CT volumetric analysis showed mean volumetric accuracy of 84.80–94.91%. The material and printing costs of developing 24 test phantoms was 83.00 Euro. CONCLUSIONS: The study shows that additive manufacturing-guided macrostructure manipulation modifies successfully the radiographic visibility of a material in CBCT imaging with 1 mm(3) resolution, helping customization of imaging phantoms.