Cargando…
Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis
The Amplatzer Amulet (AA) and Watchman devices (WD) are the 2 most frequently used devices for percutaneous LAA closure globally. OBJECTIVE: To evaluate the safety and clinical outcomes associated with these 2 devices in patients undergoing percutaneous LAA closure. METHOD: We systematically searche...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10313297/ https://www.ncbi.nlm.nih.gov/pubmed/37390240 http://dx.doi.org/10.1097/MD.0000000000034185 |
_version_ | 1785067095760830464 |
---|---|
author | Jaiswal, Vikash Ang, Song Peng Shrestha, Abhigan Babu Wajid, Zarghoona Endurance, Evbayekha Osas Ayoobkhan, Fathima Shehnaz Khan, Shazia Garimellla, Vamsi Huang, Helen Ghanim, Mohammed Song, David Sharma, Prachi Alraies, M. Chadi Biswas, Monodeep |
author_facet | Jaiswal, Vikash Ang, Song Peng Shrestha, Abhigan Babu Wajid, Zarghoona Endurance, Evbayekha Osas Ayoobkhan, Fathima Shehnaz Khan, Shazia Garimellla, Vamsi Huang, Helen Ghanim, Mohammed Song, David Sharma, Prachi Alraies, M. Chadi Biswas, Monodeep |
author_sort | Jaiswal, Vikash |
collection | PubMed |
description | The Amplatzer Amulet (AA) and Watchman devices (WD) are the 2 most frequently used devices for percutaneous LAA closure globally. OBJECTIVE: To evaluate the safety and clinical outcomes associated with these 2 devices in patients undergoing percutaneous LAA closure. METHOD: We systematically searched all electronic databases from inception until February 21, 2023. The primary endpoint was procedure related complications. Secondary endpoints were device related thrombus, stroke, cardiovascular mortality, peri device leak, systemic embolism, and all-cause mortality. RESULTS: A total of 3 randomized clinical trials with 2150 patients were included in this meta-analysis. The mean age was 75 and 76 years in the Amplatzer group and in the Watchman group, respectively. The odds of procedure-related complications (OR, 1.80 [95% CI: 1.21–2.67], P < .001) were significantly higher among patients with AA compared to the WD. However, the odds of all-cause mortality (OR, 0.75 (95% CI: 0.49–1.16), P = .20), stroke (OR, 0.79 [95% CI: 0.47–1.34], P = .39), systemic/pulmonary embolism (OR, 1.34 [95% CI: 0.30–6.04], P = .70), and major bleeding (OR, 1.10 [95% CI: 0.83–1.48], P = .50) were comparable between the two devices. The odds of device related thrombus (OR, 0.72 [95% CI: 0.46–1.14], P = .17) was comparable between both the group of patients, however the incidence of peri device leak was significantly lower in AA group (OR, 0.41 [95% CI: 0.26–0.66], P < .001) compared with WD group of patients. CONCLUSION: The AA was not superior to the Watchman device in terms of safety and efficacy. However, the Amulet occluder was associated with a higher incidence of procedure-related complications, and lower peri device leak. |
format | Online Article Text |
id | pubmed-10313297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-103132972023-07-01 Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis Jaiswal, Vikash Ang, Song Peng Shrestha, Abhigan Babu Wajid, Zarghoona Endurance, Evbayekha Osas Ayoobkhan, Fathima Shehnaz Khan, Shazia Garimellla, Vamsi Huang, Helen Ghanim, Mohammed Song, David Sharma, Prachi Alraies, M. Chadi Biswas, Monodeep Medicine (Baltimore) 3400 The Amplatzer Amulet (AA) and Watchman devices (WD) are the 2 most frequently used devices for percutaneous LAA closure globally. OBJECTIVE: To evaluate the safety and clinical outcomes associated with these 2 devices in patients undergoing percutaneous LAA closure. METHOD: We systematically searched all electronic databases from inception until February 21, 2023. The primary endpoint was procedure related complications. Secondary endpoints were device related thrombus, stroke, cardiovascular mortality, peri device leak, systemic embolism, and all-cause mortality. RESULTS: A total of 3 randomized clinical trials with 2150 patients were included in this meta-analysis. The mean age was 75 and 76 years in the Amplatzer group and in the Watchman group, respectively. The odds of procedure-related complications (OR, 1.80 [95% CI: 1.21–2.67], P < .001) were significantly higher among patients with AA compared to the WD. However, the odds of all-cause mortality (OR, 0.75 (95% CI: 0.49–1.16), P = .20), stroke (OR, 0.79 [95% CI: 0.47–1.34], P = .39), systemic/pulmonary embolism (OR, 1.34 [95% CI: 0.30–6.04], P = .70), and major bleeding (OR, 1.10 [95% CI: 0.83–1.48], P = .50) were comparable between the two devices. The odds of device related thrombus (OR, 0.72 [95% CI: 0.46–1.14], P = .17) was comparable between both the group of patients, however the incidence of peri device leak was significantly lower in AA group (OR, 0.41 [95% CI: 0.26–0.66], P < .001) compared with WD group of patients. CONCLUSION: The AA was not superior to the Watchman device in terms of safety and efficacy. However, the Amulet occluder was associated with a higher incidence of procedure-related complications, and lower peri device leak. Lippincott Williams & Wilkins 2023-06-30 /pmc/articles/PMC10313297/ /pubmed/37390240 http://dx.doi.org/10.1097/MD.0000000000034185 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. |
spellingShingle | 3400 Jaiswal, Vikash Ang, Song Peng Shrestha, Abhigan Babu Wajid, Zarghoona Endurance, Evbayekha Osas Ayoobkhan, Fathima Shehnaz Khan, Shazia Garimellla, Vamsi Huang, Helen Ghanim, Mohammed Song, David Sharma, Prachi Alraies, M. Chadi Biswas, Monodeep Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis |
title | Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis |
title_full | Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis |
title_fullStr | Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis |
title_full_unstemmed | Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis |
title_short | Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis |
title_sort | amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: a systematic review and meta-analysis |
topic | 3400 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10313297/ https://www.ncbi.nlm.nih.gov/pubmed/37390240 http://dx.doi.org/10.1097/MD.0000000000034185 |
work_keys_str_mv | AT jaiswalvikash amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT angsongpeng amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT shresthaabhiganbabu amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT wajidzarghoona amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT enduranceevbayekhaosas amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT ayoobkhanfathimashehnaz amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT khanshazia amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT garimelllavamsi amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT huanghelen amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT ghanimmohammed amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT songdavid amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT sharmaprachi amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT alraiesmchadi amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis AT biswasmonodeep amplatzeramuletversuswatchmandeviceforpercutaneousleftatrialappendageclosureasystematicreviewandmetaanalysis |