Cargando…
Gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of SARS-CoV-2 S1 antigen in saliva samples
Despite the transfer of COVID-19 from the pandemic to control, we are still in a state of uncertainty about long-term success. Therefore, there is a great need for rapid and sensitive diagnostics to sustain the control status. After several optimization trials, we developed lateral flow test (LFT) s...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10313708/ https://www.ncbi.nlm.nih.gov/pubmed/37391465 http://dx.doi.org/10.1038/s41598-023-37347-y |
_version_ | 1785067174249889792 |
---|---|
author | Maher, Sara Kamel, Manal Demerdash, Zeinab El Baz, Hanan Sayyouh, Omar Saad, Amany Ali, Noha Salah, Faten Atta, Shimaa |
author_facet | Maher, Sara Kamel, Manal Demerdash, Zeinab El Baz, Hanan Sayyouh, Omar Saad, Amany Ali, Noha Salah, Faten Atta, Shimaa |
author_sort | Maher, Sara |
collection | PubMed |
description | Despite the transfer of COVID-19 from the pandemic to control, we are still in a state of uncertainty about long-term success. Therefore, there is a great need for rapid and sensitive diagnostics to sustain the control status. After several optimization trials, we developed lateral flow test (LFT) strips for rapid detection of SARS-CoV-2 spike 1 (S1) antigen in saliva samples. For signal enhancement of our developed strips, we applied dual gold conjugates. Gold-labeled anti-S1 nanobodies (Nbs) were employed as S1 detector conjugate, while gold-labeled angiotensin-converting enzyme 2 (ACE2) was used as S1 capturing conjugate. In a parallel strip design, we used an anti-S1 monoclonal antibody (mAb) as an antigen detector instead of anti-S1 Nbs. Saliva samples were collected from 320 symptomatic subjects (180 RT-PCR confirmed positive cases and 140 confirmed negative cases) and were tested with the developed strips. In early detection for positive samples with cycle threshold (Ct ≤ 30), Nbs-based LFT strips showed higher sensitivity (97.14%) and specificity (98.57%) than mAb-based strips which gave 90.04% sensitivity and 97.86% specificity. Moreover, the limit of detection (LoD) for virus particles was lower for Nbs-based LFT (0.4 × 10(4) copies/ml) than for the mAb-based test (1.6 × 10(4) copies/ml). Our results are in favor of the use of dual gold Nbs and ACE2 conjugates in LFT strips. These signal-enhanced strips offer a sensitive diagnostic tool for rapid screening of SARS-CoV-2 S1 antigen in the easily collected saliva samples. |
format | Online Article Text |
id | pubmed-10313708 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-103137082023-07-02 Gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of SARS-CoV-2 S1 antigen in saliva samples Maher, Sara Kamel, Manal Demerdash, Zeinab El Baz, Hanan Sayyouh, Omar Saad, Amany Ali, Noha Salah, Faten Atta, Shimaa Sci Rep Article Despite the transfer of COVID-19 from the pandemic to control, we are still in a state of uncertainty about long-term success. Therefore, there is a great need for rapid and sensitive diagnostics to sustain the control status. After several optimization trials, we developed lateral flow test (LFT) strips for rapid detection of SARS-CoV-2 spike 1 (S1) antigen in saliva samples. For signal enhancement of our developed strips, we applied dual gold conjugates. Gold-labeled anti-S1 nanobodies (Nbs) were employed as S1 detector conjugate, while gold-labeled angiotensin-converting enzyme 2 (ACE2) was used as S1 capturing conjugate. In a parallel strip design, we used an anti-S1 monoclonal antibody (mAb) as an antigen detector instead of anti-S1 Nbs. Saliva samples were collected from 320 symptomatic subjects (180 RT-PCR confirmed positive cases and 140 confirmed negative cases) and were tested with the developed strips. In early detection for positive samples with cycle threshold (Ct ≤ 30), Nbs-based LFT strips showed higher sensitivity (97.14%) and specificity (98.57%) than mAb-based strips which gave 90.04% sensitivity and 97.86% specificity. Moreover, the limit of detection (LoD) for virus particles was lower for Nbs-based LFT (0.4 × 10(4) copies/ml) than for the mAb-based test (1.6 × 10(4) copies/ml). Our results are in favor of the use of dual gold Nbs and ACE2 conjugates in LFT strips. These signal-enhanced strips offer a sensitive diagnostic tool for rapid screening of SARS-CoV-2 S1 antigen in the easily collected saliva samples. Nature Publishing Group UK 2023-06-30 /pmc/articles/PMC10313708/ /pubmed/37391465 http://dx.doi.org/10.1038/s41598-023-37347-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Maher, Sara Kamel, Manal Demerdash, Zeinab El Baz, Hanan Sayyouh, Omar Saad, Amany Ali, Noha Salah, Faten Atta, Shimaa Gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of SARS-CoV-2 S1 antigen in saliva samples |
title | Gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of SARS-CoV-2 S1 antigen in saliva samples |
title_full | Gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of SARS-CoV-2 S1 antigen in saliva samples |
title_fullStr | Gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of SARS-CoV-2 S1 antigen in saliva samples |
title_full_unstemmed | Gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of SARS-CoV-2 S1 antigen in saliva samples |
title_short | Gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of SARS-CoV-2 S1 antigen in saliva samples |
title_sort | gold conjugated nanobodies in a signal-enhanced lateral flow test strip for rapid detection of sars-cov-2 s1 antigen in saliva samples |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10313708/ https://www.ncbi.nlm.nih.gov/pubmed/37391465 http://dx.doi.org/10.1038/s41598-023-37347-y |
work_keys_str_mv | AT mahersara goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples AT kamelmanal goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples AT demerdashzeinab goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples AT elbazhanan goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples AT sayyouhomar goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples AT saadamany goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples AT alinoha goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples AT salahfaten goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples AT attashimaa goldconjugatednanobodiesinasignalenhancedlateralflowteststripforrapiddetectionofsarscov2s1antigeninsalivasamples |