Cargando…

Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis

AIMS: We conducted a meta-analysis of randomised controlled trials (RCTs) of implantable haemodynamic monitoring (IHM)-guided care. METHODS: PubMed and Ovid MEDLINE were searched for RCTs of IHM in patients with heart failure (HF). Outcomes were examined in total (first and recurrent) event analyses...

Descripción completa

Detalles Bibliográficos
Autores principales: Curtain, James P, Lee, Matthew M Y, McMurray, John JV, Gardner, Roy S, Petrie, Mark C, Jhund, Pardeep S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10314022/
https://www.ncbi.nlm.nih.gov/pubmed/36522146
http://dx.doi.org/10.1136/heartjnl-2022-321885
_version_ 1785067232596852736
author Curtain, James P
Lee, Matthew M Y
McMurray, John JV
Gardner, Roy S
Petrie, Mark C
Jhund, Pardeep S
author_facet Curtain, James P
Lee, Matthew M Y
McMurray, John JV
Gardner, Roy S
Petrie, Mark C
Jhund, Pardeep S
author_sort Curtain, James P
collection PubMed
description AIMS: We conducted a meta-analysis of randomised controlled trials (RCTs) of implantable haemodynamic monitoring (IHM)-guided care. METHODS: PubMed and Ovid MEDLINE were searched for RCTs of IHM in patients with heart failure (HF). Outcomes were examined in total (first and recurrent) event analyses. RESULTS: Five trials comparing IHM-guided care with standard care alone were identified and included 2710 patients across ejection fraction (EF) ranges. Data were available for 628 patients (23.2%) with heart failure with preserved ejection fraction (HFpEF) (EF ≥50%) and 2023 patients (74.6%) with heart failure with a reduced ejection fraction (HFrEF) (EF <50%). Chronicle, CardioMEMS and HeartPOD IHMs were used. In all patients, regardless of EF, IHM-guided care reduced total HF hospitalisations (HR 0.74, 95% CI 0.66 to 0.82) and total worsening HF events (HR 0.74, 95% CI 0.66 to 0.84). In patients with HFrEF, IHM-guided care reduced total worsening HF events (HR 0.75, 95% CI 0.66 to 0.86). The effect of IHM-guided care on total worsening HF events in patients with HFpEF was uncertain (fixed-effect model: HR 0.72, 95% CI 0.59 to 0.88; random-effects model: HR 0.60, 95% CI 0.32 to 1.14). IHM-guided care did not reduce mortality (HR 0.92, 95% CI 0.71 to 1.20). IHM-guided care reduced all-cause mortality and total worsening HF events (HR 0.80, 95% CI 0.72 to 0.88). CONCLUSIONS: In patients with HF across all EFs, IHM-guided care reduced total HF hospitalisations and worsening HF events. This benefit was consistent in patients with HFrEF but not consistent in HFpEF. Further trials with pre-specified analyses of patients with an EF of ≥50% are required. PROSPERO REGISTRATION NUMBER: CRD42021253905.
format Online
Article
Text
id pubmed-10314022
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-103140222023-07-02 Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis Curtain, James P Lee, Matthew M Y McMurray, John JV Gardner, Roy S Petrie, Mark C Jhund, Pardeep S Heart Systematic Review AIMS: We conducted a meta-analysis of randomised controlled trials (RCTs) of implantable haemodynamic monitoring (IHM)-guided care. METHODS: PubMed and Ovid MEDLINE were searched for RCTs of IHM in patients with heart failure (HF). Outcomes were examined in total (first and recurrent) event analyses. RESULTS: Five trials comparing IHM-guided care with standard care alone were identified and included 2710 patients across ejection fraction (EF) ranges. Data were available for 628 patients (23.2%) with heart failure with preserved ejection fraction (HFpEF) (EF ≥50%) and 2023 patients (74.6%) with heart failure with a reduced ejection fraction (HFrEF) (EF <50%). Chronicle, CardioMEMS and HeartPOD IHMs were used. In all patients, regardless of EF, IHM-guided care reduced total HF hospitalisations (HR 0.74, 95% CI 0.66 to 0.82) and total worsening HF events (HR 0.74, 95% CI 0.66 to 0.84). In patients with HFrEF, IHM-guided care reduced total worsening HF events (HR 0.75, 95% CI 0.66 to 0.86). The effect of IHM-guided care on total worsening HF events in patients with HFpEF was uncertain (fixed-effect model: HR 0.72, 95% CI 0.59 to 0.88; random-effects model: HR 0.60, 95% CI 0.32 to 1.14). IHM-guided care did not reduce mortality (HR 0.92, 95% CI 0.71 to 1.20). IHM-guided care reduced all-cause mortality and total worsening HF events (HR 0.80, 95% CI 0.72 to 0.88). CONCLUSIONS: In patients with HF across all EFs, IHM-guided care reduced total HF hospitalisations and worsening HF events. This benefit was consistent in patients with HFrEF but not consistent in HFpEF. Further trials with pre-specified analyses of patients with an EF of ≥50% are required. PROSPERO REGISTRATION NUMBER: CRD42021253905. BMJ Publishing Group 2023-06 2022-12-15 /pmc/articles/PMC10314022/ /pubmed/36522146 http://dx.doi.org/10.1136/heartjnl-2022-321885 Text en © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Systematic Review
Curtain, James P
Lee, Matthew M Y
McMurray, John JV
Gardner, Roy S
Petrie, Mark C
Jhund, Pardeep S
Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis
title Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis
title_full Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis
title_fullStr Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis
title_full_unstemmed Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis
title_short Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis
title_sort efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: a systematic review and meta-analysis
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10314022/
https://www.ncbi.nlm.nih.gov/pubmed/36522146
http://dx.doi.org/10.1136/heartjnl-2022-321885
work_keys_str_mv AT curtainjamesp efficacyofimplantablehaemodynamicmonitoringinheartfailureacrossrangesofejectionfractionasystematicreviewandmetaanalysis
AT leematthewmy efficacyofimplantablehaemodynamicmonitoringinheartfailureacrossrangesofejectionfractionasystematicreviewandmetaanalysis
AT mcmurrayjohnjv efficacyofimplantablehaemodynamicmonitoringinheartfailureacrossrangesofejectionfractionasystematicreviewandmetaanalysis
AT gardnerroys efficacyofimplantablehaemodynamicmonitoringinheartfailureacrossrangesofejectionfractionasystematicreviewandmetaanalysis
AT petriemarkc efficacyofimplantablehaemodynamicmonitoringinheartfailureacrossrangesofejectionfractionasystematicreviewandmetaanalysis
AT jhundpardeeps efficacyofimplantablehaemodynamicmonitoringinheartfailureacrossrangesofejectionfractionasystematicreviewandmetaanalysis