Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients
BACKGROUND AND PURPOSE: Efficient workflows for adaptive proton therapy are of high importance. This study evaluated the possibility to replace repeat-CTs (reCTs) with synthetic CTs (sCTs), created based on cone-beam CTs (CBCTs), for flagging the need of plan adaptations in intensity-modulated proto...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10314284/ https://www.ncbi.nlm.nih.gov/pubmed/37397874 http://dx.doi.org/10.1016/j.phro.2023.100459 |
_version_ | 1785067281598906368 |
---|---|
author | Taasti, Vicki Trier Hattu, Djoya Peeters, Stephanie van der Salm, Anke van Loon, Judith de Ruysscher, Dirk Nilsson, Rasmus Andersson, Sebastian Engwall, Erik Unipan, Mirko Canters, Richard |
author_facet | Taasti, Vicki Trier Hattu, Djoya Peeters, Stephanie van der Salm, Anke van Loon, Judith de Ruysscher, Dirk Nilsson, Rasmus Andersson, Sebastian Engwall, Erik Unipan, Mirko Canters, Richard |
author_sort | Taasti, Vicki Trier |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Efficient workflows for adaptive proton therapy are of high importance. This study evaluated the possibility to replace repeat-CTs (reCTs) with synthetic CTs (sCTs), created based on cone-beam CTs (CBCTs), for flagging the need of plan adaptations in intensity-modulated proton therapy (IMPT) treatment of lung cancer patients. MATERIALS AND METHODS: Forty-two IMPT patients were retrospectively included. For each patient, one CBCT and a same-day reCT were included. Two commercial sCT methods were applied; one based on CBCT number correction (Cor-sCT), and one based on deformable image registration (DIR-sCT). The clinical reCT workflow (deformable contour propagation and robust dose re-computation) was performed on the reCT as well as the two sCTs. The deformed target contours on the reCT/sCTs were checked by radiation oncologists and edited if needed. A dose-volume-histogram triggered plan adaptation method was compared between the reCT and the sCTs; patients needing a plan adaptation on the reCT but not on the sCT were denoted false negatives. As secondary evaluation, dose-volume-histogram comparison and gamma analysis (2%/2mm) were performed between the reCT and sCTs. RESULTS: There were five false negatives, two for Cor-sCT and three for DIR-sCT. However, three of these were only minor, and one was caused by tumour position differences between the reCT and CBCT and not by sCT quality issues. An average gamma pass rate of 93% was obtained for both sCT methods. CONCLUSION: Both sCT methods were judged to be of clinical quality and valuable for reducing the amount of reCT acquisitions. |
format | Online Article Text |
id | pubmed-10314284 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-103142842023-07-02 Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients Taasti, Vicki Trier Hattu, Djoya Peeters, Stephanie van der Salm, Anke van Loon, Judith de Ruysscher, Dirk Nilsson, Rasmus Andersson, Sebastian Engwall, Erik Unipan, Mirko Canters, Richard Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Efficient workflows for adaptive proton therapy are of high importance. This study evaluated the possibility to replace repeat-CTs (reCTs) with synthetic CTs (sCTs), created based on cone-beam CTs (CBCTs), for flagging the need of plan adaptations in intensity-modulated proton therapy (IMPT) treatment of lung cancer patients. MATERIALS AND METHODS: Forty-two IMPT patients were retrospectively included. For each patient, one CBCT and a same-day reCT were included. Two commercial sCT methods were applied; one based on CBCT number correction (Cor-sCT), and one based on deformable image registration (DIR-sCT). The clinical reCT workflow (deformable contour propagation and robust dose re-computation) was performed on the reCT as well as the two sCTs. The deformed target contours on the reCT/sCTs were checked by radiation oncologists and edited if needed. A dose-volume-histogram triggered plan adaptation method was compared between the reCT and the sCTs; patients needing a plan adaptation on the reCT but not on the sCT were denoted false negatives. As secondary evaluation, dose-volume-histogram comparison and gamma analysis (2%/2mm) were performed between the reCT and sCTs. RESULTS: There were five false negatives, two for Cor-sCT and three for DIR-sCT. However, three of these were only minor, and one was caused by tumour position differences between the reCT and CBCT and not by sCT quality issues. An average gamma pass rate of 93% was obtained for both sCT methods. CONCLUSION: Both sCT methods were judged to be of clinical quality and valuable for reducing the amount of reCT acquisitions. Elsevier 2023-06-17 /pmc/articles/PMC10314284/ /pubmed/37397874 http://dx.doi.org/10.1016/j.phro.2023.100459 Text en © 2023 Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Taasti, Vicki Trier Hattu, Djoya Peeters, Stephanie van der Salm, Anke van Loon, Judith de Ruysscher, Dirk Nilsson, Rasmus Andersson, Sebastian Engwall, Erik Unipan, Mirko Canters, Richard Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients |
title | Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients |
title_full | Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients |
title_fullStr | Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients |
title_full_unstemmed | Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients |
title_short | Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients |
title_sort | clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10314284/ https://www.ncbi.nlm.nih.gov/pubmed/37397874 http://dx.doi.org/10.1016/j.phro.2023.100459 |
work_keys_str_mv | AT taastivickitrier clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT hattudjoya clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT peetersstephanie clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT vandersalmanke clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT vanloonjudith clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT deruysscherdirk clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT nilssonrasmus clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT anderssonsebastian clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT engwallerik clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT unipanmirko clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients AT cantersrichard clinicalevaluationofsyntheticcomputedtomographymethodsinadaptiveprotontherapyoflungcancerpatients |