Cargando…

The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing

BACKGROUND: Capillary blood is a common specimen type used for infant blood routine tests. Until now, this specimen type could only be tested with the manual mode in hematology analyzers. Manual sample mixing and loading increases the amount labor force and can be more easily affected by human facto...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Jiajing, Zhang, Ge, Wang, Yuefang, Yang, Hao, Dai, Qingkai, Guo, Siqi, Mai, Jia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10315426/
https://www.ncbi.nlm.nih.gov/pubmed/37405010
http://dx.doi.org/10.21037/cdt-23-84
_version_ 1785067501724368896
author He, Jiajing
Zhang, Ge
Wang, Yuefang
Yang, Hao
Dai, Qingkai
Guo, Siqi
Mai, Jia
author_facet He, Jiajing
Zhang, Ge
Wang, Yuefang
Yang, Hao
Dai, Qingkai
Guo, Siqi
Mai, Jia
author_sort He, Jiajing
collection PubMed
description BACKGROUND: Capillary blood is a common specimen type used for infant blood routine tests. Until now, this specimen type could only be tested with the manual mode in hematology analyzers. Manual sample mixing and loading increases the amount labor force and can be more easily affected by human factors. This study was designed to investigate the proficiency of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing. METHODS: The complete blood count (CBC) results for capillary blood were compared between the automatic and manual modes. Special types of samples, including samples with high or low volume, thalassemia red cells, high fibrinogen, high hematocrit (HCT), or high triglyceride levels, were compared and evaluated. The intraclass correlation coefficient (ICC) was used to define the agreement between the 2 modes. The industry standard Analytical Quality Specifications for Routine Tests in Clinical Hematology (WS/T 406-2012), published by the National Health Commission of China, was used to evaluate the correlation between the results from the 2 modes. RESULTS: There was good correlation between the automatic and manual modes for every type of sample, and the ICCs were all higher than 0.9. Except for high HCT or high triglyceride samples, there were no differences found between the 2 modes based on the WS/T 406-2012 standard. CONCLUSIONS: This new automatic mode utilized in the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood yielded the same results as the manual mode except in the case of samples with high HCT or triglycerides. Capillary blood might be routinely tested automatically with hematology analyzers in the near future, which might reduce the labor required and improve standardization.
format Online
Article
Text
id pubmed-10315426
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-103154262023-07-04 The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing He, Jiajing Zhang, Ge Wang, Yuefang Yang, Hao Dai, Qingkai Guo, Siqi Mai, Jia Cardiovasc Diagn Ther Original Article BACKGROUND: Capillary blood is a common specimen type used for infant blood routine tests. Until now, this specimen type could only be tested with the manual mode in hematology analyzers. Manual sample mixing and loading increases the amount labor force and can be more easily affected by human factors. This study was designed to investigate the proficiency of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing. METHODS: The complete blood count (CBC) results for capillary blood were compared between the automatic and manual modes. Special types of samples, including samples with high or low volume, thalassemia red cells, high fibrinogen, high hematocrit (HCT), or high triglyceride levels, were compared and evaluated. The intraclass correlation coefficient (ICC) was used to define the agreement between the 2 modes. The industry standard Analytical Quality Specifications for Routine Tests in Clinical Hematology (WS/T 406-2012), published by the National Health Commission of China, was used to evaluate the correlation between the results from the 2 modes. RESULTS: There was good correlation between the automatic and manual modes for every type of sample, and the ICCs were all higher than 0.9. Except for high HCT or high triglyceride samples, there were no differences found between the 2 modes based on the WS/T 406-2012 standard. CONCLUSIONS: This new automatic mode utilized in the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood yielded the same results as the manual mode except in the case of samples with high HCT or triglycerides. Capillary blood might be routinely tested automatically with hematology analyzers in the near future, which might reduce the labor required and improve standardization. AME Publishing Company 2023-05-22 2023-06-30 /pmc/articles/PMC10315426/ /pubmed/37405010 http://dx.doi.org/10.21037/cdt-23-84 Text en 2023 Cardiovascular Diagnosis and Therapy. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
He, Jiajing
Zhang, Ge
Wang, Yuefang
Yang, Hao
Dai, Qingkai
Guo, Siqi
Mai, Jia
The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing
title The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing
title_full The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing
title_fullStr The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing
title_full_unstemmed The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing
title_short The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing
title_sort possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the mindray bc-7500 crp auto hematology analyzer for capillary blood testing
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10315426/
https://www.ncbi.nlm.nih.gov/pubmed/37405010
http://dx.doi.org/10.21037/cdt-23-84
work_keys_str_mv AT hejiajing thepossibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT zhangge thepossibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT wangyuefang thepossibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT yanghao thepossibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT daiqingkai thepossibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT guosiqi thepossibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT maijia thepossibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT hejiajing possibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT zhangge possibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT wangyuefang possibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT yanghao possibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT daiqingkai possibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT guosiqi possibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting
AT maijia possibilityofautomaticcapillarybloodtestinginroutinebloodtestsanevaluationoftheautomaticmodeofthemindraybc7500crpautohematologyanalyzerforcapillarybloodtesting