Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose

There has been significant recent interest in understanding both the frequency of nuclear medicine injection infiltration and the potential for negative impact, including skin injury. However, no large-scale study has yet correlated visualized injection site activity with actual activity measurement...

Descripción completa

Detalles Bibliográficos
Autores principales: Sunderland, John J., Graves, Stephen A., York, Dusty M., Mundt, Christine A., Bartel, Twyla B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Nuclear Medicine 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10315693/
https://www.ncbi.nlm.nih.gov/pubmed/37230534
http://dx.doi.org/10.2967/jnumed.123.265891
_version_ 1785067551573671936
author Sunderland, John J.
Graves, Stephen A.
York, Dusty M.
Mundt, Christine A.
Bartel, Twyla B.
author_facet Sunderland, John J.
Graves, Stephen A.
York, Dusty M.
Mundt, Christine A.
Bartel, Twyla B.
author_sort Sunderland, John J.
collection PubMed
description There has been significant recent interest in understanding both the frequency of nuclear medicine injection infiltration and the potential for negative impact, including skin injury. However, no large-scale study has yet correlated visualized injection site activity with actual activity measurement of an infiltrate. Additionally, current skin dosimetry approaches lack sufficient detail to account for critical factors that impact the dose to the radiosensitive epidermis. Methods: From 10 imaging sites, 1,000 PET/CT patient studies were retrospectively collected. At each site, consecutive patients with the injection site in the field of view were used. The radiopharmaceutical, injected activity, time of injection and imaging, injection site, and injection method were recorded. Net injection site activity was calculated from volumes of interest. Monte Carlo image–based absorbed dose calculations were performed using the actual geometry from a patient with a minor infiltration. The simulation model used an activity distribution in the skin microanatomy based on known properties of subcutaneous fat, dermis, and epidermis. Simulations using several subcutaneous fat-to-dermis concentration ratios were performed. Absorbed dose to the epidermis, dermis, and fat were calculated along with relative γ- and β-contributions, and these findings were extrapolated to a hypothetical worst-case (470 MBq) full-injection infiltration. Results: Only 6 of 1,000 patients had activity at the injection site in excess of 370 kBq (10 μCi), with no activities greater than 1.7 MBq (45 μCi). In 460 of 1,000 patients, activity at the injection site was clearly visualized. However, quantitative assessment of activities averaged only 34 kBq (0.9 μCi), representing 0.008% of the injected activity. Calculations for the extrapolated 470-MBq infiltration resulted in a hypothetical absorbed dose to the epidermis of below 1 Gy, a factor of 2 lower than what is required for deterministic skin reactions. Analysis of the dose distribution demonstrates that the dermis acts as a β-shield for the radiation-sensitive epidermis. Dermal shielding is highly effective for low-energy (18)F positrons but less so with the higher-energy positrons of (68)Ga. Conclusion: When quantitative activity measurement criteria are used rather than visual, the frequency of PET infiltration appears substantially below frequencies previously published. Shallow doses to the epidermis from infiltration events are also likely substantially lower than previously reported because of absorption of β-particles in the dermis.
format Online
Article
Text
id pubmed-10315693
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Society of Nuclear Medicine
record_format MEDLINE/PubMed
spelling pubmed-103156932023-07-04 Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose Sunderland, John J. Graves, Stephen A. York, Dusty M. Mundt, Christine A. Bartel, Twyla B. J Nucl Med Clinical Investigation There has been significant recent interest in understanding both the frequency of nuclear medicine injection infiltration and the potential for negative impact, including skin injury. However, no large-scale study has yet correlated visualized injection site activity with actual activity measurement of an infiltrate. Additionally, current skin dosimetry approaches lack sufficient detail to account for critical factors that impact the dose to the radiosensitive epidermis. Methods: From 10 imaging sites, 1,000 PET/CT patient studies were retrospectively collected. At each site, consecutive patients with the injection site in the field of view were used. The radiopharmaceutical, injected activity, time of injection and imaging, injection site, and injection method were recorded. Net injection site activity was calculated from volumes of interest. Monte Carlo image–based absorbed dose calculations were performed using the actual geometry from a patient with a minor infiltration. The simulation model used an activity distribution in the skin microanatomy based on known properties of subcutaneous fat, dermis, and epidermis. Simulations using several subcutaneous fat-to-dermis concentration ratios were performed. Absorbed dose to the epidermis, dermis, and fat were calculated along with relative γ- and β-contributions, and these findings were extrapolated to a hypothetical worst-case (470 MBq) full-injection infiltration. Results: Only 6 of 1,000 patients had activity at the injection site in excess of 370 kBq (10 μCi), with no activities greater than 1.7 MBq (45 μCi). In 460 of 1,000 patients, activity at the injection site was clearly visualized. However, quantitative assessment of activities averaged only 34 kBq (0.9 μCi), representing 0.008% of the injected activity. Calculations for the extrapolated 470-MBq infiltration resulted in a hypothetical absorbed dose to the epidermis of below 1 Gy, a factor of 2 lower than what is required for deterministic skin reactions. Analysis of the dose distribution demonstrates that the dermis acts as a β-shield for the radiation-sensitive epidermis. Dermal shielding is highly effective for low-energy (18)F positrons but less so with the higher-energy positrons of (68)Ga. Conclusion: When quantitative activity measurement criteria are used rather than visual, the frequency of PET infiltration appears substantially below frequencies previously published. Shallow doses to the epidermis from infiltration events are also likely substantially lower than previously reported because of absorption of β-particles in the dermis. Society of Nuclear Medicine 2023-07 /pmc/articles/PMC10315693/ /pubmed/37230534 http://dx.doi.org/10.2967/jnumed.123.265891 Text en © 2023 by the Society of Nuclear Medicine and Molecular Imaging. https://creativecommons.org/licenses/by/4.0/Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.
spellingShingle Clinical Investigation
Sunderland, John J.
Graves, Stephen A.
York, Dusty M.
Mundt, Christine A.
Bartel, Twyla B.
Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose
title Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose
title_full Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose
title_fullStr Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose
title_full_unstemmed Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose
title_short Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose
title_sort multicenter evaluation of frequency and impact of activity infiltration in pet imaging, including microscale modeling of skin-absorbed dose
topic Clinical Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10315693/
https://www.ncbi.nlm.nih.gov/pubmed/37230534
http://dx.doi.org/10.2967/jnumed.123.265891
work_keys_str_mv AT sunderlandjohnj multicenterevaluationoffrequencyandimpactofactivityinfiltrationinpetimagingincludingmicroscalemodelingofskinabsorbeddose
AT gravesstephena multicenterevaluationoffrequencyandimpactofactivityinfiltrationinpetimagingincludingmicroscalemodelingofskinabsorbeddose
AT yorkdustym multicenterevaluationoffrequencyandimpactofactivityinfiltrationinpetimagingincludingmicroscalemodelingofskinabsorbeddose
AT mundtchristinea multicenterevaluationoffrequencyandimpactofactivityinfiltrationinpetimagingincludingmicroscalemodelingofskinabsorbeddose
AT barteltwylab multicenterevaluationoffrequencyandimpactofactivityinfiltrationinpetimagingincludingmicroscalemodelingofskinabsorbeddose