Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study

OBJECTIVE: The aim was to compare the reliability of cephalometric analysis using a smartphone-based application with conventional computer-based imaging software. METHODS: Pre-treatment cephalometric radiographs of 50 subjects (26 males, 24 females; mean age, 19.2 years; ±4.2) were traced using the...

Descripción completa

Detalles Bibliográficos
Autores principales: Chugh, Vinay Kumar, Bhatia, Navleen Kaur, Shastri, Dipti, Shankar, Sam Prasanth, Singh, Surjit, Sardana, Rinkle
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10318850/
https://www.ncbi.nlm.nih.gov/pubmed/37346006
http://dx.doi.org/10.4274/TurkJOrthod.2022.2022.60
_version_ 1785068130752528384
author Chugh, Vinay Kumar
Bhatia, Navleen Kaur
Shastri, Dipti
Shankar, Sam Prasanth
Singh, Surjit
Sardana, Rinkle
author_facet Chugh, Vinay Kumar
Bhatia, Navleen Kaur
Shastri, Dipti
Shankar, Sam Prasanth
Singh, Surjit
Sardana, Rinkle
author_sort Chugh, Vinay Kumar
collection PubMed
description OBJECTIVE: The aim was to compare the reliability of cephalometric analysis using a smartphone-based application with conventional computer-based imaging software. METHODS: Pre-treatment cephalometric radiographs of 50 subjects (26 males, 24 females; mean age, 19.2 years; ±4.2) were traced using the OneCeph® application and Dolphin imaging software(®). Two independent observers identified seventeen landmarks and measured fourteen cephalometric measurements at an interval of. Interobserver and intraobserver reliability were evaluated using the intraclass correlation coefficient. Student’s t-test was used to compare the means of two measurement methods for observer 1 and observer 2. Additionally, the time taken to complete the cephalometric measurements was also compared between the two methods. RESULTS: Good (ICC 0.75-0.90) to excellent (ICC 0.90-1.00) interobserver and intraobserver reliability was observed for all hard and soft tissue measurements with both methods. No significant differences were found between the two measurement methods for both observers (p<0.05). OneCeph application took significantly more time to complete the analysis than Dolphin imaging software (p<0.001). CONCLUSION: Cephalometric measurements made through a smartphone-based application showed good to excellent interobserver and intraobserver reliability and are comparable with the computer-based software. Therefore, it can be recommended for clinical use. The time taken to complete the cephalometric measurements was more with a smartphone-based application (OneCeph application) compared to computer-based software (Dolphin imaging software).
format Online
Article
Text
id pubmed-10318850
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-103188502023-07-05 Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study Chugh, Vinay Kumar Bhatia, Navleen Kaur Shastri, Dipti Shankar, Sam Prasanth Singh, Surjit Sardana, Rinkle Turk J Orthod Original Article OBJECTIVE: The aim was to compare the reliability of cephalometric analysis using a smartphone-based application with conventional computer-based imaging software. METHODS: Pre-treatment cephalometric radiographs of 50 subjects (26 males, 24 females; mean age, 19.2 years; ±4.2) were traced using the OneCeph® application and Dolphin imaging software(®). Two independent observers identified seventeen landmarks and measured fourteen cephalometric measurements at an interval of. Interobserver and intraobserver reliability were evaluated using the intraclass correlation coefficient. Student’s t-test was used to compare the means of two measurement methods for observer 1 and observer 2. Additionally, the time taken to complete the cephalometric measurements was also compared between the two methods. RESULTS: Good (ICC 0.75-0.90) to excellent (ICC 0.90-1.00) interobserver and intraobserver reliability was observed for all hard and soft tissue measurements with both methods. No significant differences were found between the two measurement methods for both observers (p<0.05). OneCeph application took significantly more time to complete the analysis than Dolphin imaging software (p<0.001). CONCLUSION: Cephalometric measurements made through a smartphone-based application showed good to excellent interobserver and intraobserver reliability and are comparable with the computer-based software. Therefore, it can be recommended for clinical use. The time taken to complete the cephalometric measurements was more with a smartphone-based application (OneCeph application) compared to computer-based software (Dolphin imaging software). Galenos Publishing 2023-06-22 /pmc/articles/PMC10318850/ /pubmed/37346006 http://dx.doi.org/10.4274/TurkJOrthod.2022.2022.60 Text en © Copyright 2023 by Turkish Orthodontic Society | Turkish Journal of Orthodontics, published by Galenos Publishing House. https://creativecommons.org/licenses/by-nc/4.0/Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle Original Article
Chugh, Vinay Kumar
Bhatia, Navleen Kaur
Shastri, Dipti
Shankar, Sam Prasanth
Singh, Surjit
Sardana, Rinkle
Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study
title Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study
title_full Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study
title_fullStr Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study
title_full_unstemmed Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study
title_short Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study
title_sort interobserver and intraobserver reliability of cephalometric measurements performed on smartphone-based application and computer-based imaging software: a comparative study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10318850/
https://www.ncbi.nlm.nih.gov/pubmed/37346006
http://dx.doi.org/10.4274/TurkJOrthod.2022.2022.60
work_keys_str_mv AT chughvinaykumar interobserverandintraobserverreliabilityofcephalometricmeasurementsperformedonsmartphonebasedapplicationandcomputerbasedimagingsoftwareacomparativestudy
AT bhatianavleenkaur interobserverandintraobserverreliabilityofcephalometricmeasurementsperformedonsmartphonebasedapplicationandcomputerbasedimagingsoftwareacomparativestudy
AT shastridipti interobserverandintraobserverreliabilityofcephalometricmeasurementsperformedonsmartphonebasedapplicationandcomputerbasedimagingsoftwareacomparativestudy
AT shankarsamprasanth interobserverandintraobserverreliabilityofcephalometricmeasurementsperformedonsmartphonebasedapplicationandcomputerbasedimagingsoftwareacomparativestudy
AT singhsurjit interobserverandintraobserverreliabilityofcephalometricmeasurementsperformedonsmartphonebasedapplicationandcomputerbasedimagingsoftwareacomparativestudy
AT sardanarinkle interobserverandintraobserverreliabilityofcephalometricmeasurementsperformedonsmartphonebasedapplicationandcomputerbasedimagingsoftwareacomparativestudy