Cargando…

Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization

BACKGROUND: This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL/METHODS: Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Sh...

Descripción completa

Detalles Bibliográficos
Autores principales: Gupta, Shekhar, Sayed, Mohammed E., Gupta, Bharti, Patel, Aditya, Mattoo, Khurshid, Alotaibi, Noura Turki, Alnemi, Salha I., Jokhadar, Hossam F., Mashhor, Boshra Mohammed, Othman, Maha Abdu, Mugri, Maryam H., Porwal, Amit, Patil, Shankargouda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10318931/
https://www.ncbi.nlm.nih.gov/pubmed/37386761
http://dx.doi.org/10.12659/MSM.940949
_version_ 1785068142297350144
author Gupta, Shekhar
Sayed, Mohammed E.
Gupta, Bharti
Patel, Aditya
Mattoo, Khurshid
Alotaibi, Noura Turki
Alnemi, Salha I.
Jokhadar, Hossam F.
Mashhor, Boshra Mohammed
Othman, Maha Abdu
Mugri, Maryam H.
Porwal, Amit
Patil, Shankargouda
author_facet Gupta, Shekhar
Sayed, Mohammed E.
Gupta, Bharti
Patel, Aditya
Mattoo, Khurshid
Alotaibi, Noura Turki
Alnemi, Salha I.
Jokhadar, Hossam F.
Mashhor, Boshra Mohammed
Othman, Maha Abdu
Mugri, Maryam H.
Porwal, Amit
Patil, Shankargouda
author_sort Gupta, Shekhar
collection PubMed
description BACKGROUND: This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL/METHODS: Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Shade) and ceramic (Vita classic) shade guide with a calibrated spectrophotometer (Vita Easy Shade Advance 4.0). Seventy-two composite resin disk samples with 6 different shades (A1/B1, A2/B2, A3/D3, A3.5/B3, A4/C4, and C2/C3) (n=12 each) were divided into 2 groups (Gp) – Gp A (Autoclave) and Gp C (Chemical) (15 cycles) – to assess their influence on respective shades. Mean values calculated the color differences (ΔE) while differences in color values (L*a*b*) were graded on the National Bureau of Standards (NBS) 6-grade scale and assessed for Clinical Acceptance/Perceptible Threshold (CAT), (CPT). All differences were considered significant if the color difference ΔE was ≥3.3. RESULTS: Only 2 out of 12 Shade tabs (C2C3, A4C4) of composite resin matched to Vita shade tab C2 and C4 (ΔE ≤3.3). Both groups showed notable color differences after respective sterilization protocols, with color differences in Gp A significantly higher than Gp C (ΔE ≥3.3). Within groups, all shades in Gp A showed remarkably different color changes, with shade C2C3 and A1B1 being denoted as clinically unacceptable. CONCLUSIONS: Manufacturer-provided shade guides do not match ceramic shades as claimed and chemical sterilization using 10% Deconex was associated with less color changes than with autoclave sterilization.
format Online
Article
Text
id pubmed-10318931
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-103189312023-07-05 Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization Gupta, Shekhar Sayed, Mohammed E. Gupta, Bharti Patel, Aditya Mattoo, Khurshid Alotaibi, Noura Turki Alnemi, Salha I. Jokhadar, Hossam F. Mashhor, Boshra Mohammed Othman, Maha Abdu Mugri, Maryam H. Porwal, Amit Patil, Shankargouda Med Sci Monit Lab/In Vitro Research BACKGROUND: This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL/METHODS: Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Shade) and ceramic (Vita classic) shade guide with a calibrated spectrophotometer (Vita Easy Shade Advance 4.0). Seventy-two composite resin disk samples with 6 different shades (A1/B1, A2/B2, A3/D3, A3.5/B3, A4/C4, and C2/C3) (n=12 each) were divided into 2 groups (Gp) – Gp A (Autoclave) and Gp C (Chemical) (15 cycles) – to assess their influence on respective shades. Mean values calculated the color differences (ΔE) while differences in color values (L*a*b*) were graded on the National Bureau of Standards (NBS) 6-grade scale and assessed for Clinical Acceptance/Perceptible Threshold (CAT), (CPT). All differences were considered significant if the color difference ΔE was ≥3.3. RESULTS: Only 2 out of 12 Shade tabs (C2C3, A4C4) of composite resin matched to Vita shade tab C2 and C4 (ΔE ≤3.3). Both groups showed notable color differences after respective sterilization protocols, with color differences in Gp A significantly higher than Gp C (ΔE ≥3.3). Within groups, all shades in Gp A showed remarkably different color changes, with shade C2C3 and A1B1 being denoted as clinically unacceptable. CONCLUSIONS: Manufacturer-provided shade guides do not match ceramic shades as claimed and chemical sterilization using 10% Deconex was associated with less color changes than with autoclave sterilization. International Scientific Literature, Inc. 2023-06-30 /pmc/articles/PMC10318931/ /pubmed/37386761 http://dx.doi.org/10.12659/MSM.940949 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Lab/In Vitro Research
Gupta, Shekhar
Sayed, Mohammed E.
Gupta, Bharti
Patel, Aditya
Mattoo, Khurshid
Alotaibi, Noura Turki
Alnemi, Salha I.
Jokhadar, Hossam F.
Mashhor, Boshra Mohammed
Othman, Maha Abdu
Mugri, Maryam H.
Porwal, Amit
Patil, Shankargouda
Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization
title Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization
title_full Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization
title_fullStr Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization
title_full_unstemmed Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization
title_short Comparison of Composite Resin (Duo-Shade) Shade Guide with Vita Ceramic Shades Before and After Chemical and Autoclave Sterilization
title_sort comparison of composite resin (duo-shade) shade guide with vita ceramic shades before and after chemical and autoclave sterilization
topic Lab/In Vitro Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10318931/
https://www.ncbi.nlm.nih.gov/pubmed/37386761
http://dx.doi.org/10.12659/MSM.940949
work_keys_str_mv AT guptashekhar comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT sayedmohammede comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT guptabharti comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT pateladitya comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT mattookhurshid comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT alotaibinouraturki comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT alnemisalhai comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT jokhadarhossamf comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT mashhorboshramohammed comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT othmanmahaabdu comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT mugrimaryamh comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT porwalamit comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization
AT patilshankargouda comparisonofcompositeresinduoshadeshadeguidewithvitaceramicshadesbeforeandafterchemicalandautoclavesterilization