Cargando…

Trans Palpebral Intraocular Pressure Measurement by Diaton Tonometer and Central Corneal Thickness in Eyes before and after Transepithelial Photorefractive Keratectomy of Saudi Patients

PURPOSE: The influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurement by Diaton is debatable. We present a correlation of CCT to transpalpebral IOP (tpIOP) and its determinants in patients undergoing transepithelial photorefractive keratectomy (TPRK) in Saudi Arabia. ME...

Descripción completa

Detalles Bibliográficos
Autor principal: Alzuhairy, Sultan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10319074/
https://www.ncbi.nlm.nih.gov/pubmed/37408723
http://dx.doi.org/10.4103/meajo.meajo_156_22
_version_ 1785068167965442048
author Alzuhairy, Sultan
author_facet Alzuhairy, Sultan
author_sort Alzuhairy, Sultan
collection PubMed
description PURPOSE: The influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurement by Diaton is debatable. We present a correlation of CCT to transpalpebral IOP (tpIOP) and its determinants in patients undergoing transepithelial photorefractive keratectomy (TPRK) in Saudi Arabia. METHODS: In this cross-sectional study held in 2022, the IOP of patients undergoing TPRK was measured by Diaton tonometer. The CCT was measured before and 1 week after refractive surgery. The correlation coefficient of CCT and IOP and its Pearson P value were estimated. The effects of gender, type of refractive error (RE), and corneal epithelial thickness (CET) on the correlation of IOP to CCT were reviewed. RESULTS: We studied 202 eyes in 101 patients (Male: Female, 47:53; age 25.7 ± 5.8 years). The tpIOP was 15.1 ± 2.8 mmHg before, 15.9 ± 2.8 mmHg 1 week after, and 15.7 ± 4.1 mmHg 1 month after TPRK. The CCT was significantly correlated with tpIOP before surgery (Pearson correlation 0.168, P = 0.017) and after tPRK (Pearson correlation 0.246, P < 0.001). Gender (P = 0.96), CET (P = 0.43), and type of RE (P = 0.99) were not significant determinants of correlation between CCT and tpIOP before TPRK. The correlation of tpIOP and CCT was not affected by gender (P = 0.07), CET (P = 0.39), and type of RE (P = 0.13). CONCLUSION: CCT should be considered before interpreting tpIOP measured by with Diaton. Diaton could be a useful tool to monitor IOP changes in young patients undergoing refractive surgery.
format Online
Article
Text
id pubmed-10319074
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-103190742023-07-05 Trans Palpebral Intraocular Pressure Measurement by Diaton Tonometer and Central Corneal Thickness in Eyes before and after Transepithelial Photorefractive Keratectomy of Saudi Patients Alzuhairy, Sultan Middle East Afr J Ophthalmol Original Article PURPOSE: The influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurement by Diaton is debatable. We present a correlation of CCT to transpalpebral IOP (tpIOP) and its determinants in patients undergoing transepithelial photorefractive keratectomy (TPRK) in Saudi Arabia. METHODS: In this cross-sectional study held in 2022, the IOP of patients undergoing TPRK was measured by Diaton tonometer. The CCT was measured before and 1 week after refractive surgery. The correlation coefficient of CCT and IOP and its Pearson P value were estimated. The effects of gender, type of refractive error (RE), and corneal epithelial thickness (CET) on the correlation of IOP to CCT were reviewed. RESULTS: We studied 202 eyes in 101 patients (Male: Female, 47:53; age 25.7 ± 5.8 years). The tpIOP was 15.1 ± 2.8 mmHg before, 15.9 ± 2.8 mmHg 1 week after, and 15.7 ± 4.1 mmHg 1 month after TPRK. The CCT was significantly correlated with tpIOP before surgery (Pearson correlation 0.168, P = 0.017) and after tPRK (Pearson correlation 0.246, P < 0.001). Gender (P = 0.96), CET (P = 0.43), and type of RE (P = 0.99) were not significant determinants of correlation between CCT and tpIOP before TPRK. The correlation of tpIOP and CCT was not affected by gender (P = 0.07), CET (P = 0.39), and type of RE (P = 0.13). CONCLUSION: CCT should be considered before interpreting tpIOP measured by with Diaton. Diaton could be a useful tool to monitor IOP changes in young patients undergoing refractive surgery. Wolters Kluwer - Medknow 2023-05-25 /pmc/articles/PMC10319074/ /pubmed/37408723 http://dx.doi.org/10.4103/meajo.meajo_156_22 Text en Copyright: © 2023 Middle East African Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Alzuhairy, Sultan
Trans Palpebral Intraocular Pressure Measurement by Diaton Tonometer and Central Corneal Thickness in Eyes before and after Transepithelial Photorefractive Keratectomy of Saudi Patients
title Trans Palpebral Intraocular Pressure Measurement by Diaton Tonometer and Central Corneal Thickness in Eyes before and after Transepithelial Photorefractive Keratectomy of Saudi Patients
title_full Trans Palpebral Intraocular Pressure Measurement by Diaton Tonometer and Central Corneal Thickness in Eyes before and after Transepithelial Photorefractive Keratectomy of Saudi Patients
title_fullStr Trans Palpebral Intraocular Pressure Measurement by Diaton Tonometer and Central Corneal Thickness in Eyes before and after Transepithelial Photorefractive Keratectomy of Saudi Patients
title_full_unstemmed Trans Palpebral Intraocular Pressure Measurement by Diaton Tonometer and Central Corneal Thickness in Eyes before and after Transepithelial Photorefractive Keratectomy of Saudi Patients
title_short Trans Palpebral Intraocular Pressure Measurement by Diaton Tonometer and Central Corneal Thickness in Eyes before and after Transepithelial Photorefractive Keratectomy of Saudi Patients
title_sort trans palpebral intraocular pressure measurement by diaton tonometer and central corneal thickness in eyes before and after transepithelial photorefractive keratectomy of saudi patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10319074/
https://www.ncbi.nlm.nih.gov/pubmed/37408723
http://dx.doi.org/10.4103/meajo.meajo_156_22
work_keys_str_mv AT alzuhairysultan transpalpebralintraocularpressuremeasurementbydiatontonometerandcentralcornealthicknessineyesbeforeandaftertransepithelialphotorefractivekeratectomyofsaudipatients