Cargando…

Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass

We describe a successful case of hybrid revascularization of a totally occluded aortobifemoral bypass with retrograde use of the Rotarex S catheter (BD) and complete relining with a Gore Excluder iliac branch endoprosthesis (W.L. Gore & Associates). The repair procedure was performed with femora...

Descripción completa

Detalles Bibliográficos
Autores principales: Terpin, Andrea Maria, Baccani, Luigi, Parlani, Gianbattista, Isernia, Giacomo, Fino, Gianluigi, Simonte, Gioele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10319313/
https://www.ncbi.nlm.nih.gov/pubmed/37408943
http://dx.doi.org/10.1016/j.jvscit.2023.101234
_version_ 1785068222618271744
author Terpin, Andrea Maria
Baccani, Luigi
Parlani, Gianbattista
Isernia, Giacomo
Fino, Gianluigi
Simonte, Gioele
author_facet Terpin, Andrea Maria
Baccani, Luigi
Parlani, Gianbattista
Isernia, Giacomo
Fino, Gianluigi
Simonte, Gioele
author_sort Terpin, Andrea Maria
collection PubMed
description We describe a successful case of hybrid revascularization of a totally occluded aortobifemoral bypass with retrograde use of the Rotarex S catheter (BD) and complete relining with a Gore Excluder iliac branch endoprosthesis (W.L. Gore & Associates). The repair procedure was performed with femoral surgical access and percutaneous brachial access. Despite left renal artery endoclamping, after the final angiography, deployment of a covered stent in the left renal artery was needed because of residual thrombotic material at the vessel ostium. The procedure was completed with reconstruction using a common femoral artery Dacron graft and bilateral complete iliac surgical branch relining using self-expanding covered stents, with recovery of distal pulses.
format Online
Article
Text
id pubmed-10319313
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103193132023-07-05 Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass Terpin, Andrea Maria Baccani, Luigi Parlani, Gianbattista Isernia, Giacomo Fino, Gianluigi Simonte, Gioele J Vasc Surg Cases Innov Tech Case report We describe a successful case of hybrid revascularization of a totally occluded aortobifemoral bypass with retrograde use of the Rotarex S catheter (BD) and complete relining with a Gore Excluder iliac branch endoprosthesis (W.L. Gore & Associates). The repair procedure was performed with femoral surgical access and percutaneous brachial access. Despite left renal artery endoclamping, after the final angiography, deployment of a covered stent in the left renal artery was needed because of residual thrombotic material at the vessel ostium. The procedure was completed with reconstruction using a common femoral artery Dacron graft and bilateral complete iliac surgical branch relining using self-expanding covered stents, with recovery of distal pulses. Elsevier 2023-05-25 /pmc/articles/PMC10319313/ /pubmed/37408943 http://dx.doi.org/10.1016/j.jvscit.2023.101234 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Terpin, Andrea Maria
Baccani, Luigi
Parlani, Gianbattista
Isernia, Giacomo
Fino, Gianluigi
Simonte, Gioele
Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass
title Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass
title_full Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass
title_fullStr Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass
title_full_unstemmed Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass
title_short Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass
title_sort off-label use of the gore excluder iliac branch endoprosthesis in association with the rotarex s catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10319313/
https://www.ncbi.nlm.nih.gov/pubmed/37408943
http://dx.doi.org/10.1016/j.jvscit.2023.101234
work_keys_str_mv AT terpinandreamaria offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass
AT baccaniluigi offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass
AT parlanigianbattista offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass
AT iserniagiacomo offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass
AT finogianluigi offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass
AT simontegioele offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass