Cargando…
Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass
We describe a successful case of hybrid revascularization of a totally occluded aortobifemoral bypass with retrograde use of the Rotarex S catheter (BD) and complete relining with a Gore Excluder iliac branch endoprosthesis (W.L. Gore & Associates). The repair procedure was performed with femora...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10319313/ https://www.ncbi.nlm.nih.gov/pubmed/37408943 http://dx.doi.org/10.1016/j.jvscit.2023.101234 |
_version_ | 1785068222618271744 |
---|---|
author | Terpin, Andrea Maria Baccani, Luigi Parlani, Gianbattista Isernia, Giacomo Fino, Gianluigi Simonte, Gioele |
author_facet | Terpin, Andrea Maria Baccani, Luigi Parlani, Gianbattista Isernia, Giacomo Fino, Gianluigi Simonte, Gioele |
author_sort | Terpin, Andrea Maria |
collection | PubMed |
description | We describe a successful case of hybrid revascularization of a totally occluded aortobifemoral bypass with retrograde use of the Rotarex S catheter (BD) and complete relining with a Gore Excluder iliac branch endoprosthesis (W.L. Gore & Associates). The repair procedure was performed with femoral surgical access and percutaneous brachial access. Despite left renal artery endoclamping, after the final angiography, deployment of a covered stent in the left renal artery was needed because of residual thrombotic material at the vessel ostium. The procedure was completed with reconstruction using a common femoral artery Dacron graft and bilateral complete iliac surgical branch relining using self-expanding covered stents, with recovery of distal pulses. |
format | Online Article Text |
id | pubmed-10319313 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-103193132023-07-05 Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass Terpin, Andrea Maria Baccani, Luigi Parlani, Gianbattista Isernia, Giacomo Fino, Gianluigi Simonte, Gioele J Vasc Surg Cases Innov Tech Case report We describe a successful case of hybrid revascularization of a totally occluded aortobifemoral bypass with retrograde use of the Rotarex S catheter (BD) and complete relining with a Gore Excluder iliac branch endoprosthesis (W.L. Gore & Associates). The repair procedure was performed with femoral surgical access and percutaneous brachial access. Despite left renal artery endoclamping, after the final angiography, deployment of a covered stent in the left renal artery was needed because of residual thrombotic material at the vessel ostium. The procedure was completed with reconstruction using a common femoral artery Dacron graft and bilateral complete iliac surgical branch relining using self-expanding covered stents, with recovery of distal pulses. Elsevier 2023-05-25 /pmc/articles/PMC10319313/ /pubmed/37408943 http://dx.doi.org/10.1016/j.jvscit.2023.101234 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case report Terpin, Andrea Maria Baccani, Luigi Parlani, Gianbattista Isernia, Giacomo Fino, Gianluigi Simonte, Gioele Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass |
title | Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass |
title_full | Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass |
title_fullStr | Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass |
title_full_unstemmed | Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass |
title_short | Off-label use of the Gore Excluder iliac branch endoprosthesis in association with the Rotarex S catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass |
title_sort | off-label use of the gore excluder iliac branch endoprosthesis in association with the rotarex s catheter to achieve total endovascular recanalization of an occluded aortobifemoral bypass |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10319313/ https://www.ncbi.nlm.nih.gov/pubmed/37408943 http://dx.doi.org/10.1016/j.jvscit.2023.101234 |
work_keys_str_mv | AT terpinandreamaria offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass AT baccaniluigi offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass AT parlanigianbattista offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass AT iserniagiacomo offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass AT finogianluigi offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass AT simontegioele offlabeluseofthegoreexcluderiliacbranchendoprosthesisinassociationwiththerotarexscathetertoachievetotalendovascularrecanalizationofanoccludedaortobifemoralbypass |