Cargando…

Is sleep captured during a standard daytime EEG sufficient to diagnose Electrical Status Epilepticus in Sleep

Electrical Status epilepticus of sleep (SES) is an EEG pattern where there is significant activation of epileptiform activity in NREM sleep. A spike wave index (SWI) of > 80–85% is often labelled as typical SES. We aimed to explore if sleep during a standard daytime-EEG, as compared an overnight-...

Descripción completa

Detalles Bibliográficos
Autores principales: Shah, Snehal, Ghosh, Soumya, Nagarajan, Lakshmi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10320242/
https://www.ncbi.nlm.nih.gov/pubmed/37416499
http://dx.doi.org/10.1016/j.ebr.2023.100611
_version_ 1785068411203616768
author Shah, Snehal
Ghosh, Soumya
Nagarajan, Lakshmi
author_facet Shah, Snehal
Ghosh, Soumya
Nagarajan, Lakshmi
author_sort Shah, Snehal
collection PubMed
description Electrical Status epilepticus of sleep (SES) is an EEG pattern where there is significant activation of epileptiform activity in NREM sleep. A spike wave index (SWI) of > 80–85% is often labelled as typical SES. We aimed to explore if sleep during a standard daytime-EEG, as compared an overnight-EEG, was adequate to diagnose ESES. Ten children with daytime and overnight studies suggestive of SES were audited. SWI and Spike Wave Density (SWD) were calculated for 5-minute epochs of wake in the daytime and overnight study, as well daytime-EEG sleep and first and last NREM cycle in the overnight-EEG. SWI in daytime NREM was not significantly different from SWI in the first sleep cycle of the overnight study. SWI in the last sleep cycle was significantly lower than the first sleep cycle in the overnight-EEG. SWD was significantly higher in the first sleep cycle in the overnight-EEG than the daytime sleep and the last NREM cycle. SES may be diagnosed in NREM sleep from a daytime-EEG study. Larger studies are needed to explore the significance of the disparity between SWI and SWD in the first and last NREM cycles in the overnight study.
format Online
Article
Text
id pubmed-10320242
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-103202422023-07-06 Is sleep captured during a standard daytime EEG sufficient to diagnose Electrical Status Epilepticus in Sleep Shah, Snehal Ghosh, Soumya Nagarajan, Lakshmi Epilepsy Behav Rep Article Electrical Status epilepticus of sleep (SES) is an EEG pattern where there is significant activation of epileptiform activity in NREM sleep. A spike wave index (SWI) of > 80–85% is often labelled as typical SES. We aimed to explore if sleep during a standard daytime-EEG, as compared an overnight-EEG, was adequate to diagnose ESES. Ten children with daytime and overnight studies suggestive of SES were audited. SWI and Spike Wave Density (SWD) were calculated for 5-minute epochs of wake in the daytime and overnight study, as well daytime-EEG sleep and first and last NREM cycle in the overnight-EEG. SWI in daytime NREM was not significantly different from SWI in the first sleep cycle of the overnight study. SWI in the last sleep cycle was significantly lower than the first sleep cycle in the overnight-EEG. SWD was significantly higher in the first sleep cycle in the overnight-EEG than the daytime sleep and the last NREM cycle. SES may be diagnosed in NREM sleep from a daytime-EEG study. Larger studies are needed to explore the significance of the disparity between SWI and SWD in the first and last NREM cycles in the overnight study. Elsevier 2023-06-12 /pmc/articles/PMC10320242/ /pubmed/37416499 http://dx.doi.org/10.1016/j.ebr.2023.100611 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Shah, Snehal
Ghosh, Soumya
Nagarajan, Lakshmi
Is sleep captured during a standard daytime EEG sufficient to diagnose Electrical Status Epilepticus in Sleep
title Is sleep captured during a standard daytime EEG sufficient to diagnose Electrical Status Epilepticus in Sleep
title_full Is sleep captured during a standard daytime EEG sufficient to diagnose Electrical Status Epilepticus in Sleep
title_fullStr Is sleep captured during a standard daytime EEG sufficient to diagnose Electrical Status Epilepticus in Sleep
title_full_unstemmed Is sleep captured during a standard daytime EEG sufficient to diagnose Electrical Status Epilepticus in Sleep
title_short Is sleep captured during a standard daytime EEG sufficient to diagnose Electrical Status Epilepticus in Sleep
title_sort is sleep captured during a standard daytime eeg sufficient to diagnose electrical status epilepticus in sleep
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10320242/
https://www.ncbi.nlm.nih.gov/pubmed/37416499
http://dx.doi.org/10.1016/j.ebr.2023.100611
work_keys_str_mv AT shahsnehal issleepcapturedduringastandarddaytimeeegsufficienttodiagnoseelectricalstatusepilepticusinsleep
AT ghoshsoumya issleepcapturedduringastandarddaytimeeegsufficienttodiagnoseelectricalstatusepilepticusinsleep
AT nagarajanlakshmi issleepcapturedduringastandarddaytimeeegsufficienttodiagnoseelectricalstatusepilepticusinsleep