Cargando…

The Complex Management of Mechanical Prosthetic Valve Thrombosis

Mechanical prosthetic valve thrombosis (PVT) is a serious condition that is associated with various life-threatening complications. The utilization of multimodality imaging techniques is critical in identifying this etiology. Its management is complex and often requires repeat surgical valve replace...

Descripción completa

Detalles Bibliográficos
Autores principales: Saeed Al-Asad, Khalid, Sabanci, Rand, El-khatib, Layan, Qintar, Mohammed, Hanson, Christopher
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10321028/
https://www.ncbi.nlm.nih.gov/pubmed/37416047
http://dx.doi.org/10.7759/cureus.41214
_version_ 1785068554332143616
author Saeed Al-Asad, Khalid
Sabanci, Rand
El-khatib, Layan
Qintar, Mohammed
Hanson, Christopher
author_facet Saeed Al-Asad, Khalid
Sabanci, Rand
El-khatib, Layan
Qintar, Mohammed
Hanson, Christopher
author_sort Saeed Al-Asad, Khalid
collection PubMed
description Mechanical prosthetic valve thrombosis (PVT) is a serious condition that is associated with various life-threatening complications. The utilization of multimodality imaging techniques is critical in identifying this etiology. Its management is complex and often requires repeat surgical valve replacements. Our report describes the case of a 48-year-old female who presented with mechanical mitral valve thrombosis in the setting of subtherapeutic anticoagulation. Due to her complex surgical history, nonsurgical therapeutic options were initially pursued for management. Through shared decision-making and after exhaustion of other alternatives, she was maintained on optimized medical therapy and was scheduled for repeat elective surgery. After compliance with medical therapy and close monitoring, she improved significantly, and her underlying pathology completely resolved, eliminating the need for surgery. This report indicates that the management of mechanical prosthetic valve thrombosis should be individualized and emphasizes the importance of involving a multidisciplinary team of medical and surgical professionals to achieve the best clinical outcomes.
format Online
Article
Text
id pubmed-10321028
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-103210282023-07-06 The Complex Management of Mechanical Prosthetic Valve Thrombosis Saeed Al-Asad, Khalid Sabanci, Rand El-khatib, Layan Qintar, Mohammed Hanson, Christopher Cureus Cardiac/Thoracic/Vascular Surgery Mechanical prosthetic valve thrombosis (PVT) is a serious condition that is associated with various life-threatening complications. The utilization of multimodality imaging techniques is critical in identifying this etiology. Its management is complex and often requires repeat surgical valve replacements. Our report describes the case of a 48-year-old female who presented with mechanical mitral valve thrombosis in the setting of subtherapeutic anticoagulation. Due to her complex surgical history, nonsurgical therapeutic options were initially pursued for management. Through shared decision-making and after exhaustion of other alternatives, she was maintained on optimized medical therapy and was scheduled for repeat elective surgery. After compliance with medical therapy and close monitoring, she improved significantly, and her underlying pathology completely resolved, eliminating the need for surgery. This report indicates that the management of mechanical prosthetic valve thrombosis should be individualized and emphasizes the importance of involving a multidisciplinary team of medical and surgical professionals to achieve the best clinical outcomes. Cureus 2023-06-30 /pmc/articles/PMC10321028/ /pubmed/37416047 http://dx.doi.org/10.7759/cureus.41214 Text en Copyright © 2023, Saeed Al-Asad et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiac/Thoracic/Vascular Surgery
Saeed Al-Asad, Khalid
Sabanci, Rand
El-khatib, Layan
Qintar, Mohammed
Hanson, Christopher
The Complex Management of Mechanical Prosthetic Valve Thrombosis
title The Complex Management of Mechanical Prosthetic Valve Thrombosis
title_full The Complex Management of Mechanical Prosthetic Valve Thrombosis
title_fullStr The Complex Management of Mechanical Prosthetic Valve Thrombosis
title_full_unstemmed The Complex Management of Mechanical Prosthetic Valve Thrombosis
title_short The Complex Management of Mechanical Prosthetic Valve Thrombosis
title_sort complex management of mechanical prosthetic valve thrombosis
topic Cardiac/Thoracic/Vascular Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10321028/
https://www.ncbi.nlm.nih.gov/pubmed/37416047
http://dx.doi.org/10.7759/cureus.41214
work_keys_str_mv AT saeedalasadkhalid thecomplexmanagementofmechanicalprostheticvalvethrombosis
AT sabancirand thecomplexmanagementofmechanicalprostheticvalvethrombosis
AT elkhatiblayan thecomplexmanagementofmechanicalprostheticvalvethrombosis
AT qintarmohammed thecomplexmanagementofmechanicalprostheticvalvethrombosis
AT hansonchristopher thecomplexmanagementofmechanicalprostheticvalvethrombosis
AT saeedalasadkhalid complexmanagementofmechanicalprostheticvalvethrombosis
AT sabancirand complexmanagementofmechanicalprostheticvalvethrombosis
AT elkhatiblayan complexmanagementofmechanicalprostheticvalvethrombosis
AT qintarmohammed complexmanagementofmechanicalprostheticvalvethrombosis
AT hansonchristopher complexmanagementofmechanicalprostheticvalvethrombosis